Glass Microfiber Separator Roll 200μm×60mm 100m

$230.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Glass microfiber separator roll, 200μm thick, 60mm wide, 200m length. ISO 18782 compliant uniform porosity. Low resistance, high liquid retention. Order now.

GLASS MICROFIBER SEPARATOR ROLL 200UM X 60MM

RESEARCH GRADE MATERIAL

Product Overview

This premium porous battery separator roll features an engineered polyolefin base membrane structured via a premium glass fiber configuration to establish ultimate cell-to-cell consistency. Designed specifically as an uncompromised baseline testing control during complex electrochemical evaluation phases, this high-purity matrix eliminates critical structural and chemical variables across institutional testing lines. By facilitating optimized liquid electrolyte absorption and uniform ion transport channels, it delivers exceptional chemical protection against degradation, securing reliable baseline variable removal for professional electrolyte validation and device testing platforms.

Technical Specifications

PARAMETER DETAILS
1. Core Device & Device Root Substrate Designation
Product Model EQ-Lib-GMSR
Material Composition Premium Glass fiber structural matrix
Available Delivery Form Factor Roll-only configuration (Optimized for standard continuous assembly architectures)
2. Membrane & Porous Barrier Parameters
Nominal Thickness Profile ~200 μm Symmetrical Cross-Section Thickness
Geometric Width Profile 60 mm Precision Calibrated Slitting Boundaries
Continuous Unit Quantity 100 pcs Equivalent Total Structural Output Layout
3. Quality Compliance, Geometric Tolerance & Freight Matrix
Manufacturing Rules Processed under strict ISO 18782 laboratory filter material quality standards to maintain uniform porosity distributions with zero parameter drift conditions
Dimensional Precision Agreement Geometric accuracy parameters meet verified ISO 286 tolerance specifications, generating a seamless operational match
Alternative Options Explore our full glass fiber battery separator portfolio or custom running roll scales. For specialized procurement price scaling, analytical certificates, or quick quotation requests, please contact our support team.

Key Features & Advantages

  • Reliable Electrode Isolation: Advanced glass microfiber structure effectively separates the positive and negative electrode elements of batteries and supercapacitors, eliminating short circuits caused by direct contact layer defects.
  • Efficient Ion Migration Channel: Engineered porous network configurations enable fluid electrolyte saturation and unhindered ion translation loops, lowering overall energy losses during continuous high-power execution cycles.
  • Stable Structural Performance: The mechanical durability of premium glass fiber ensures that the multi-layer matrix preserves structural integrity across volatile charge-discharge conditions.

APPLICATION SCPE (Battery Manufacturing & R&D): Tailored for the production of various battery types, elevating operational safety thresholds, cycle stability, and internal energy conversion loops.
APPLICATION SCOPE (Supercapacitor Production & Testing): Maintains long-term structural integrity under severe power densities, minimizes structural impedance, and assists next-generation high-output product lines.
IMPORTANT NOTICE: This microstructural glass fiber network is sensitive to raw ambient humidity and uneven winding force profiles. Keep rolls tightly packed and integrate into production exclusively within clean, anhydrous testing zones to preserve consistent liquid transmission kinetics before definitive cell safety validation.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com

This procedure provides steps to integrate the separator roll into energy storage devices to ensure proper electrode isolation and ion transport. The separator must be handled in a clean, dry environment to prevent contamination and maintain structural integrity.

Required Equipment: Sharp blade or precision cutter, Clean, lint-free work surface, Tweezers

  1. Unwind
    Unwind the separator roll on a clean surface to the required length for your cell assembly.
  2. Cut
    Cut the separator to the exact dimensions using a sharp blade to avoid fraying edges.
  3. Inspect
    Inspect the cut piece for any visible defects or contaminants before placement.
  4. Position
    Position the separator between the positive and negative electrodes to ensure full coverage without overlap.
  5. Secure
    Secure the assembly to prevent displacement during subsequent cell sealing or stacking.
  6. Saturate
    Saturate the separator with electrolyte to enable ion migration and charge-discharge cycling.

How does the 200 μm thickness of the Atomfair EQ-Lib-GMSR glass microfiber diaphragm affect its ion transport performance and mechanical integrity compared to thinner separators?

The 200 μm thickness provides a balance between mechanical integrity and ion transport efficiency—the open porous structure enables efficient electrolyte penetration and unimpeded ion migration, while the glass fiber mechanical strength maintains structural integrity under high-power charge-discharge conditions. Uniform porosity compliant with ISO 18782 ensures consistent performance, and the thickness is optimized for both battery and supercapacitor applications to reduce energy loss.

What are the critical dimensional compatibility requirements for integrating the Atomfair EQ-Lib-GMSR glass microfiber roll into existing battery or supercapacitor assembly lines?

The 60mm width and 200 μm thickness conform to ISO 286 tolerance specifications, ensuring dimensional compatibility with mainstream battery and supercapacitor production lines. However, the roll-only sales form (200m length) requires end users to have slitting capability to customize electrode dimensions. The outer packaging dimensions are 16in x 8in x 8in, which should be considered for storage and handling.

What handling and storage precautions are required for the glass microfiber separator roll to maintain its structural integrity and performance?

The roll is packaged according to international shipping standards to prevent damage during transit and storage. To maintain the glass fiber structure and porous integrity, it should be stored in a dry, clean environment and handled with care during unrolling to avoid mechanical stress or contamination. The 200m continuous length requires appropriate support to prevent sagging or creasing.

This glass microfiber separator roll delivers reliable electrode isolation and efficient ion migration for batteries and supercapacitors, though its fixed 60 mm width and approximate 200 μm thickness necessitate careful integration planning for non-standard cell geometries.

Positive

  • Reliable Electrode Isolation: The glass microfiber structure effectively separates positive and negative electrodes, preventing short circuits and improving the safety of energy storage devices.
  • Efficient Ion Migration Channel: The optimized porous structure enables smooth electrolyte penetration and unimpeded ion transport, enhancing charge-discharge efficiency and cycle life while reducing energy loss during high-power operation.

Trade-offs

  • Fixed 60 mm Width: The roll is supplied at a fixed 60 mm width, requiring slitting or cutting for integration into cells with non-standard geometries or automated assembly lines.
  • Approximate Thickness Tolerance: The specified thickness of ~200 μm carries inherent manufacturing tolerances, which may affect stacking uniformity and require tolerance analysis during cell assembly.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).