Product Overview
This solvent treatment system adopts the water bath absorption principle, which is a professional device specially used for the recovery and treatment of NMP waste gas in the lithium battery coating process, achieving efficient dual effects of solvent recovery and environmental protection exhaust gas treatment.
Functional Features
- Equipped with a two-stage water bath treatment unit, which has good recovery and treatment effects on NMP solvent and dust in waste gas.
- The inner liner is made of fully-welded stainless steel with excellent corrosion resistance; the outer shell is treated with powder coating, with an elegant, neat and durable appearance.
- Based on the core water bath working principle, it recovers NMP waste gas generated in the coating process, equipped with an active self-priming air intake structure, and can be directly used with tap water for convenient and efficient operation.
Technical Parameters
| Item | Specification |
|---|---|
| Treatment Capacity | 600m³/h |
| Inlet Air Temperature | ≤150℃ |
| Recovery Rate | >80% |
| Treatment Object | Water-soluble solvent waste gas |
| Power Supply | 380V, 50Hz |
| Power | 1.5KW |
| Installation Dimension | L1000×W860×H1750mm |
If you’re interested, have any questions, or have specific customization requirements, please feel free to contact us at inquiry@atomfair.com.
This document outlines the operational constraints for the Atomfair-LBEU-4892 solvent treatment system. The system is designed for the recovery of NMP waste gas from lithium battery coating processes and requires specific environmental and utility conditions.
- Inlet Air Temperature Limit: The inlet air temperature must not exceed 150°C to prevent damage to the water bath absorption unit.
- Power Supply Requirement: The system requires a 380V, 50Hz power supply and consumes 1.5kW during operation.
- Water Supply Compatibility: The system is designed to operate with tap water, which serves as the absorption medium for the water bath treatment process.
- Corrosion Resistance: The fully-welded stainless steel inner liner provides corrosion resistance against the water-soluble solvent waste gas.
This procedure describes the safe and effective operation of the Atomfair-LBEU-4892 solvent treatment system for NMP waste gas recovery. The steps cover initial setup, operation, and shutdown procedures.
Required Equipment: Tap water supply connection, 380V, 50Hz power source
- Connect utilities
Connect the system to a 380V, 50Hz power source and attach a tap water supply line to the water bath inlet. - Verify water level
Confirm that the water bath is filled to the recommended level with tap water before starting the system. - Start the system
Turn on the main power switch and initiate the self-priming air intake to begin drawing NMP waste gas into the system. - Monitor operation
Monitor the system's operation to ensure the inlet air temperature remains at or below 150°C and the treatment capacity is maintained at 600m³/h. - Shut down safely
After completing the treatment process, turn off the system and disconnect the power and water supplies.
What is the maximum inlet air temperature the Atomfair-LBEU-4892 solvent treatment system can handle?
The system can handle inlet air temperatures up to 150°C. This is a critical parameter for direct integration with coating equipment exhaust streams, ensuring safe and efficient operation without thermal damage to the internal components.
Can the Atomfair-LBEU-4892 be integrated with existing lithium battery coating lines using tap water?
Yes, the system is designed for direct use with tap water, eliminating the need for specialized water treatment infrastructure. Its active self-priming air intake structure facilitates straightforward connection to coating process exhaust streams, simplifying installation and operational setup.
What are the utility and space requirements for installing the Atomfair-LBEU-4892?
The system requires a 380V, 50Hz power supply and consumes 1.5kW of power. Its compact installation footprint is L1000×W860×H1750mm, making it suitable for facilities with limited floor space. The fully-welded stainless steel inner liner and powder-coated outer shell ensure durability and corrosion resistance in demanding industrial environments.
The Atomfair-LBEU-4892 Solvent Treatment System is a water bath absorption unit rated at 600 m³/h for NMP recovery in lithium battery coating lines, achieving >80% recovery with a fully-welded stainless steel liner and self-priming air intake for direct tap water use.
Positive
- Two-stage water bath recovery: The two-stage water bath treatment unit effectively recovers NMP solvent and captures dust from exhaust gas, providing dual benefits of solvent recovery and emission control in coating processes.
- Corrosion-resistant welded liner: The fully-welded stainless steel inner liner offers excellent corrosion resistance, ensuring durability and longevity when handling aggressive solvent-laden air streams.
Trade-offs
- High-temperature inlet limit: The system requires inlet air temperature to be ≤150°C; higher temperatures may necessitate upstream cooling, adding process integration complexity.
- Three-phase power requirement: Operation requires a 380V, 50Hz three-phase power supply, which may not be available in all laboratory or pilot-scale facilities without electrical infrastructure upgrades.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).