LNPM-1C Liquid Nitrogen Planetary Ball Mill -40°C 0.75kW 4-Station

$3,502.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

LNPM-1C liquid nitrogen planetary ball mill, -40°C to 20°C, 0.75kW, 70-810 rpm, 1L. Four-station, vacuum/inert atmosphere grinding. 4-5L/h LN₂ consumption. Lab & research grade.

SKU: AFPBM12C
Category: ,
Tags:
Brands:

Description

ATOMFAIR LNPM-1C LIQUID NITROGEN PLANETARY BALL MILL -40°C 4-STATION

RESEARCH GRADE EQUIPMENT

Product Overview

The mill places grinding jars within an insulated chamber continuously supplied with liquid nitrogen, which rapidly absorbs heat generated by high-speed grinding ball motion to maintain a persistent low-temperature grinding environment. Purpose-built for cryogenic ultrafine grinding research, this system is essential for material mixing, ultrafine grinding, small-batch sample preparation, pilot trials, and new product development. The LNPM series features a compact design with complete functionality, low operating noise, high grinding efficiency, and simple operation—making it the dedicated powder grinding equipment for university, research institute, and enterprise R&D laboratories. The four-station vacuum inert atmosphere grinding configuration allows simultaneous preparation of four different samples in a single run, with compatibility for vacuum grinding jars enabling inert or vacuum atmosphere cryogenic grinding. The system operates at 220V/110V, 0.75 kW with a temperature control range from -40°C to 20°C and liquid nitrogen consumption of 4–5 L/h under 0–10°C operating conditions.The temperature control system maintains the grinding chamber within a range of -40°C to 20°C through continuous liquid nitrogen injection. Under typical 0–10°C operating conditions, liquid nitrogen consumption is approximately 4–5 L/h. The system is compatible with 30 L or 50 L liquid nitrogen storage tanks. The LNPM series spans from 1 L to 12 L total volume, with the LNPM-1C through LNPM-6C powered by 0.75 kW motors and the LNPM-8C through LNPM-12C powered by 1.5 kW motors. All models feature four grinding stations with a standard configuration including the main grinding unit; grinding jars and balls are ordered separately with multiple material options available.

Standard Configuration List

Item Configuration Description
Main Grinding Unit 1 pc
Grinding Jars (Order Separately) Available Materials: Al₂O₃ PU PTFE Ceramic SS Nylon
Grinding Balls (Order Separately) Available Materials: WC-Co Al₂O₃ PU-Fe Agate YSZ HCCI 304SS

LNPM Series Full Model Specifications

MODEL TOTAL VOLUME VOLTAGE POWER ROTATION (rpm) NET WEIGHT DIMENSIONS (mm)
LNPM-1C 1 L 220V / 110V 0.75 kW 70–810 83 kg 750×470×590
LNPM-2C 2 L 220V / 110V 0.75 kW 70–810 85 kg 750×470×590
LNPM-4C 4 L 220V / 110V 0.75 kW 70–810 88 kg 750×470×590
LNPM-6C 6 L 220V / 110V 0.75 kW 70–670 93 kg 750×470×590
LNPM-8C 8 L 220V / 110V 1.5 kW 70–580 150 kg 880×560×670
LNPM-10C 10 L 220V / 110V 1.5 kW 70–580 150 kg 880×560×670
LNPM-12C 12 L 220V / 110V 1.5 kW 70–580 150 kg 880×560×670

Key Features & Advantages

  • Liquid Nitrogen Cooling with -40°C to 20°C Temperature Range: Continuous liquid nitrogen injection into the insulated chamber rapidly absorbs grinding-generated heat, maintaining the grinding environment at temperatures as low as -40°C for true cryogenic processing of temperature-sensitive materials.
  • Four-Station Simultaneous Grinding with Independent Sample Processing: The standard four-position grinding configuration enables simultaneous preparation of four different samples in a single run, dramatically improving experimental throughput for comparative material studies.
  • Vacuum and Inert Atmosphere Grinding Compatibility: The system supports vacuum grinding jars, enabling inert gas or vacuum atmosphere cryogenic grinding for air-sensitive materials that require complete environmental isolation during processing.
  • Compact Design with Low Noise and High Efficiency: The small-footprint design (460 × 660 × 720 mm) with approximately 80 kg weight delivers low operating noise and high grinding efficiency, making it ideal for space-constrained research laboratories requiring dedicated cryogenic powder processing capability.

APPLICATION SCOPE: Widely used in geology, mining, metallurgy, electronics, building materials, ceramics, chemical engineering, light industry, pharmaceuticals, and environmental protection for low-temperature grinding. Specifically suitable for electronic ceramics, structural ceramics, magnetic materials, lithium cobalt oxide, lithium manganese oxide, catalysts, phosphors, long-afterglow luminescent powders, rare-earth polishing powders, glass micro-powders, fuel cells, zinc oxide varistors, piezoelectric ceramics, nanopowders, multilayer ceramic capacitors (MLCC), PTC/NTC thermistors, dielectric ceramics, alumina ceramics, zirconia ceramics, zinc oxide powders, cobalt oxide powders, nickel-zinc ferrites, and manganese-zinc ferrites where cryogenic processing is essential.
PACKAGING: This listing is priced for the main unit only. The standard configuration includes 1 pc grinding host machine with liquid nitrogen cooling system and four-station grinding platform. Grinding jars (Al₂O₃, PU, PTFE, Ceramic, SS, Nylon) and grinding balls (WC-Co, Al₂O₃, PU-Fe, Agate, YSZ, HCCI, 304SS) are ordered separately. The LNPM series is available from 1 L through 12 L models. Compatible with 30 L or 50 L liquid nitrogen storage tanks. Installation guidance and operational training support are provided upon request.
IMPORTANT NOTICE: The listed price is for the main unit; grinding jars and balls must be ordered separately. Liquid nitrogen storage tank (30 L or 50 L) is required for operation and ordered separately. Liquid nitrogen consumption is approximately 4–5 L/h under 0–10°C operating conditions. Adequate ventilation is required in the operating area due to nitrogen gas displacement. Always follow cryogenic safety protocols when handling liquid nitrogen. For detailed installation, operation, and maintenance instructions, consult the user manual prior to first use. If you have specific requirements for other LNPM models or custom configurations, please contact us at inquiry@atomfair.com.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This equipment presents active mechanical and cryogenic hazards requiring strict operational controls. Storage must be in a dry, temperature-controlled environment away from flammable materials and moisture condensation.

  • Electrical Safety: Ensure the mill is connected to a grounded outlet with the correct voltage and current rating as specified on the nameplate.
  • Cryogenic Protection: When operating at -40°C, verify that all accessible surfaces are insulated and that the operator wears cryogenic gloves to prevent cold contact burns.
  • Mechanical Guarding: Confirm that the safety interlock switch on the lid is functional and that the mill cannot start when the cover is open.
  • Ventilation Requirement: Operate the ball mill in a well-ventilated area or under a fume hood when grinding materials that may release hazardous dust or vapors.
  • Grinding Media Integrity: Inspect grinding jars and balls for cracks or wear before each use to prevent catastrophic failure during high-speed operation.

Follow these steps to safely prepare and operate the mill under cryogenic conditions. Always wear appropriate personal protective equipment including safety glasses, lab coat, and cryogenic gloves.

Required Equipment: PBM-12C main unit, Grinding jar with lid and sealing gasket, Grinding balls (specified diameter and material), Crucible tongs or handling tool for cold jars

  1. Inspect Equipment
    Inspect the mill, jars, and balls for any damage, wear, or contamination before operation.
  2. Assemble Grinding Jar
    Load the sample and grinding balls into the jar, leaving adequate headspace, and seal the lid securely with the gasket.
  3. Install Jar on Mill
    Place the assembled jar into the mill receptacle and lock it into position using the clamping mechanism.
  4. Set Cryogenic Parameters
    Set the desired speed, cycle time, and temperature to -40°C using the control panel, ensuring the cryogenic system is engaged.
  5. Start Grinding Cycle
    Close the safety cover, confirm that the interlock is engaged, and press the start button to begin the grinding cycle.
  6. Monitor Operation
    Monitor the mill during operation for unusual vibrations, noise, or temperature deviations and stop immediately if any anomaly occurs.
  7. Retrieve and Clean
    After the cycle ends and the mill has returned to ambient temperature, open the cover, remove the jar using tongs, and clean all components thoroughly.

How does the -40°C cryogenic capability affect grinding efficiency for heat-sensitive materials compared to ambient temperature operation?

The -40°C cryogenic environment suppresses thermal degradation and embrittles materials, enabling finer grinding of heat-sensitive samples without compromising structural integrity. This capability is integral to the mill's design for processing polymers, biological samples, and low-melting-point compounds, leveraging the planetary motion mode that provides high energy density through revolution and rotation.

What type of grinding jars and balls are required for cryogenic operation, and are they included with the main machine?

Grinding jars and balls are not included; they must be ordered separately as the listed price covers the main machine only. The mill supports jars made of materials such as stainless steel, ceramics, and polyurethane, with stainless steel or ceramic jars recommended for cryogenic operation due to their thermal stability and resistance to low-temperature stress.

What safety and infrastructure requirements are necessary for operating the cryogenic planetary ball mill at -40°C?

The mill is equipped with safety switches, overload protection, and a low-noise design that comply with laboratory safety standards. For cryogenic operation, proper ventilation and personal protective equipment are advised to handle potential cold exposure, and the variable frequency speed control allows programmed operation to ensure repeatability and safe shutdown.

The PBM-12C Cryogenic Planetary Ball Mill offers high-energy planetary grinding with cryogenic temperature control down to -40°C, enabling processing of temperature-sensitive materials. It achieves uniform particle sizes down to 0.1 micron, but requires separate purchase of grinding jars and balls and is limited to small-batch applications.

Positive

  • Planetary motion high energy density: The composite revolution and rotation motion provides high impact and friction energy, significantly improving grinding efficiency over traditional mills.
  • Ultrafine particle size down to 0.1 micron: Three-dimensional motion trajectory ensures thorough mixing and uniform particle size distribution, achieving sub-micron grinding results.

Trade-offs

  • Essential accessories not included: The base price covers the main unit only; appropriate grinding jars and balls are required but must be ordered separately, adding to procurement steps.
  • Small-batch capacity only: Designed for small-batch and high-precision experiments, this mill is not intended for continuous or large-volume production.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Additional information

Weight 150 kg
Dimensions 88 × 56 × 67 cm