Liquid Nitrogen Planetary Ball Mill 12 L 4-Station ATOMFAIR®

Price range: $5,198.00 through $19,486.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade LNPM-12C cryogenic planetary ball mill with 12 L volume, 4×3 L jars, -40°C to 20°C control, and 70–580 rpm speed. Order now.

ATOMFAIR LNPM-12C LIQUID NITROGEN PLANETARY BALL MILL -40°C 4-STATION

RESEARCH & PRODUCTION GRADE EQUIPMENT

Product Overview

The ATOMFAIR LNPM-12C Liquid Nitrogen Planetary Ball Mill — a 4-station research-grade cryogenic grinding unit with 12 L total volume (4 × 3 L jars), 1.5 kW motor, 70–580 rpm rotation speed, 220V/110V universal voltage and a -40°C to 20°C temperature control range — places grinding jars within an insulated chamber continuously supplied with liquid nitrogen, which rapidly absorbs heat generated by high-speed grinding ball motion to maintain a persistent low-temperature grinding environment. Purpose-built for cryogenic ultrafine grinding research and small-batch production, this system is essential for material mixing, ultrafine grinding, sample preparation, pilot trials, and new product development. The LNPM series features a compact design with complete functionality, low operating noise, high grinding efficiency, and simple operation—making it the dedicated powder grinding equipment for university, research institute, and enterprise R&D laboratories. The four-station vacuum inert atmosphere grinding configuration allows simultaneous preparation of four different samples in a single run, with compatibility for vacuum grinding jars enabling inert or vacuum atmosphere cryogenic grinding. Under 0–10°C operating conditions, liquid nitrogen consumption is approximately 4–5 L/h.

Standard Configuration List

Item Configuration Description
Main Grinding Unit (Included in Price) 1 pc
Liquid Nitrogen Tank (Included in Price) 100 L Empty LN2 Tank
Grinding Jars (Order Separately) 4 pcs of 3 L grinding jars (Order Separately)
Available Materials: WC-Co · Al₂O₃ · Agate · YSZ · SS · PU · Ceramic · Nylon
Grinding Balls (Order Separately) 40% of the jar capacity
Available Materials: WC-Co · Al₂O₃ · Agate · YSZ · SS · IC-PU

LNPM Series Full Model Specifications

MODEL TOTAL VOLUME VOLTAGE POWER ROTATION (rpm) NET WEIGHT DIMENSIONS (mm) RECOMMENDED LN2 TANK
LNPM-1C 1 L 220V / 110V 0.75 kW 70–810 83 kg 750×470×590 30 L
LNPM-2C 2 L 220V / 110V 0.75 kW 70–810 85 kg 750×470×590 30 L
LNPM-4C 4 L 220V / 110V 0.75 kW 70–810 88 kg 750×470×590 50 L
LNPM-6C 6 L 220V / 110V 0.75 kW 70–670 93 kg 750×470×590 50 L
LNPM-8C 8 L 220V / 110V 1.5 kW 70–580 150 kg 880×560×670 50 L
LNPM-10C 10 L 220V / 110V 1.5 kW 70–580 150 kg 880×560×670 100 L
LNPM-12C 12 L 220V / 110V 1.5 kW 70–580 150 kg 880×560×670 100 L

Key Features & Advantages

  • Liquid Nitrogen Cooling with -40°C to 20°C Temperature Range: Continuous liquid nitrogen injection into the insulated chamber rapidly absorbs grinding-generated heat, maintaining the grinding environment at temperatures as low as -40°C for true cryogenic processing of temperature-sensitive materials.
  • Four-Station Simultaneous Grinding with Independent Sample Processing: The standard four-position grinding configuration enables simultaneous preparation of four different samples in a single run, dramatically improving experimental throughput for comparative material studies.
  • Vacuum and Inert Atmosphere Grinding Compatibility: The system supports vacuum grinding jars, enabling inert gas or vacuum atmosphere cryogenic grinding for air-sensitive materials that require complete environmental isolation during processing.
  • Enhanced Production Capacity with 12 L Total Volume (4 × 3 L): The LNPM-12C features an enhanced 12 L total volume supporting 4 standard 3 L grinding jars, offering increased sample throughput for pilot-scale production and larger-batch applications while maintaining consistent cryogenic temperature control across all jars.

APPLICATION SCOPE: Widely used in geology, mining, metallurgy, electronics, building materials, ceramics, chemical engineering, light industry, pharmaceuticals, and environmental protection for low-temperature grinding. Specifically suitable for electronic ceramics, structural ceramics, magnetic materials, lithium cobalt oxide, lithium manganese oxide, catalysts, phosphors, long-afterglow luminescent powders, rare-earth polishing powders, glass micro-powders, fuel cells, zinc oxide varistors, piezoelectric ceramics, nanopowders, multilayer ceramic capacitors (MLCC), PTC/NTC thermistors, dielectric ceramics, alumina ceramics, zirconia ceramics, zinc oxide powders, cobalt oxide powders, nickel-zinc ferrites, and manganese-zinc ferrites where cryogenic processing is essential.
PACKAGING: This listing is priced for the main unit only. The standard configuration includes 1 pc grinding host machine with liquid nitrogen cooling system and four-station grinding platform. Includes 100 L empty LN2 tank. Grinding jars and grinding balls are ordered separately. The LNPM series is available from 1 L through 12 L models. Compatible with 30 L, 50 L, or 100 L liquid nitrogen storage tanks. Installation guidance and operational training support are provided upon request.
IMPORTANT NOTICE: The listed price is for the main unit; grinding jars and grinding balls must be ordered separately. 100 L liquid nitrogen tank is included with the main unit. Liquid nitrogen consumption is approximately 4–5 L/h under 0–10°C operating conditions. Adequate ventilation is required in the operating area due to nitrogen gas displacement. Always follow cryogenic safety protocols when handling liquid nitrogen. For detailed installation, operation, and maintenance instructions, consult the user manual prior to first use. If you have specific requirements for other LNPM models or custom configurations, please contact us at inquiry@atomfair.com.
TAILORED SOLUTIONS FOR RESEARCH & PRODUCTION
Contact our engineering team for technical support or official quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Operate the LNPM-12C only in well-ventilated areas to prevent nitrogen asphyxiation. Maintain liquid nitrogen supply at 4–5 L/h under 0–10°C operating conditions and ensure all cryogenic safety protocols are followed.

  • Ventilation Requirement: Ensure adequate ventilation in the operating area to prevent oxygen displacement by nitrogen gas.
  • Cryogenic Safety: Always wear appropriate cryogenic gloves and face shield when handling liquid nitrogen or cold components.
  • Temperature Range: The grinding chamber maintains -40°C to 20°C; do not exceed this range to avoid thermal stress on components.
  • Jar Compatibility: Use only grinding jars and media rated for cryogenic temperatures and compatible with the mill's clamping system.
  • LN2 Supply: Maintain a continuous liquid nitrogen supply at 4–5 L/h to sustain the desired low temperature.

Prepare the mill by securing the grinding jars and connecting the liquid nitrogen supply. Set the desired temperature and rotation speed, then initiate the grinding cycle while monitoring cryogen levels.

Required Equipment: Liquid nitrogen supply (100 L tank included), Cryogenic gloves, Face shield, Grinding jars and media

  1. Inspect the mill
    Inspect the mill and ensure the chamber is clean and dry before use.
  2. Load jars with sample and media
    Fill the grinding jars with the sample material and media to 40% of jar capacity.
  3. Secure jars on platform
    Secure the jars onto the four-station platform and lock the clamps.
  4. Connect LN2 supply
    Connect the liquid nitrogen supply to the insulated chamber and set the temperature controller to the desired setpoint.
  5. Set rotation speed
    Set the rotation speed between 70 and 580 rpm using the control panel.
  6. Start grinding cycle
    Initiate the grinding cycle and monitor the liquid nitrogen consumption rate.
  7. Warm up before opening
    After completion, allow the chamber to warm to room temperature before opening to prevent condensation.

What is the liquid nitrogen consumption rate of the LNPM-12C under typical cryogenic grinding conditions?

Under 0–10°C operating conditions, liquid nitrogen consumption is approximately 4–5 L/h. The system includes a 100 L empty LN2 tank for supply.

Does the LNPM-12C support vacuum or inert atmosphere grinding for air-sensitive materials?

Yes, the four-station vacuum inert atmosphere grinding configuration supports vacuum grinding jars, enabling inert gas or vacuum atmosphere cryogenic grinding for air-sensitive materials that require complete environmental isolation during processing.

What infrastructure and safety measures are needed for operating the LNPM-12C with liquid nitrogen?

Adequate ventilation is required in the operating area due to nitrogen gas displacement. Always follow cryogenic safety protocols when handling liquid nitrogen. The system includes a 100 L empty LN2 tank; liquid nitrogen consumption is approximately 4–5 L/h under 0–10°C conditions.

The ATOMFAIR LNPM-12C is a 4-station cryogenic planetary ball mill with 12 L total volume and -40°C to 20°C temperature control via liquid nitrogen injection, designed for ultrafine grinding of temperature-sensitive and air-sensitive materials at pilot scale.

Positive

  • Cryogenic grinding down to -40°C: Continuous liquid nitrogen injection into the insulated chamber rapidly absorbs heat from grinding, maintaining a stable low-temperature environment as low as -40°C for processing temperature-sensitive materials such as electronic ceramics, polymers, and pharmaceuticals.
  • 4-station simultaneous independent grinding: Four standard grinding positions allow simultaneous preparation of up to four different samples in a single run, dramatically increasing throughput for comparative material studies and pilot-scale production.

Trade-offs

  • Continuous liquid nitrogen supply required: Under 0–10°C operating conditions, liquid nitrogen consumption is approximately 4–5 L/h, requiring a constant supply of LN2 and imposing ongoing operational costs and infrastructure for cryogenic fluid handling.
  • Ventilation needed for nitrogen displacement: Adequate ventilation in the operating area is mandatory due to nitrogen gas displacement of oxygen, necessitating lab safety infrastructure and protocols to prevent asphyxiation hazards.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Weight 950 kg
Dimensions 160 × 107 × 125 cm
Combinations

Main Unit, Main Unit +4 Al₂O₃ Jars & Media, Main Unit +4 YSZ Jars & Media, Main Unit +4 Agate Jars & Media