Cryogenic Planetary Ball Mill LNPM-8C 8 L ATOMFAIR®

Price range: $7,534.00 through $17,238.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade LNPM-8C cryogenic planetary ball mill with 8 L volume, 4×2 L stations, -40°C to 20°C control, 70–580 rpm, and 1.5 kW motor. Order now.

ATOMFAIR LNPM-8C LIQUID NITROGEN PLANETARY BALL MILL -40°C 4-STATION

RESEARCH & PRODUCTION GRADE EQUIPMENT

Product Overview

The ATOMFAIR LNPM-8C Liquid Nitrogen Planetary Ball Mill — a 4-station research-grade cryogenic grinding unit with 8 L total volume (4 × 2 L jars), 1.5 kW motor, 70–580 rpm rotation speed, 220V/110V universal voltage and a -40°C to 20°C temperature control range — places grinding jars within an insulated chamber continuously supplied with liquid nitrogen, which rapidly absorbs heat generated by high-speed grinding ball motion to maintain a persistent low-temperature grinding environment. Purpose-built for cryogenic ultrafine grinding research and small-batch production, this system is essential for material mixing, ultrafine grinding, sample preparation, pilot trials, and new product development. The LNPM series features a compact design with complete functionality, low operating noise, high grinding efficiency, and simple operation—making it the dedicated powder grinding equipment for university, research institute, and enterprise R&D laboratories. The four-station vacuum inert atmosphere grinding configuration allows simultaneous preparation of four different samples in a single run, with compatibility for vacuum grinding jars enabling inert or vacuum atmosphere cryogenic grinding. Under 0–10°C operating conditions, liquid nitrogen consumption is approximately 4–5 L/h.

Standard Configuration List

Item Configuration Description
Main Grinding Unit (Included in Price) 1 pc
Liquid Nitrogen Tank (Included in Price) 50 L Empty LN2 Tank
Grinding Jars (Order Separately) 4 pcs of 2 L grinding jars
Available Materials: WC-Co · Al₂O₃ · Agate · YSZ · SS · PU · Ceramic · Nylon
Grinding Balls (Order Separately) 40% of the jar capacity
Available Materials: WC-Co · Al₂O₃ · Agate · YSZ · SS · IC-PU

LNPM Series Full Model Specifications

MODEL TOTAL VOLUME VOLTAGE POWER ROTATION (rpm) NET WEIGHT DIMENSIONS (mm) RECOMMENDED LN2 TANK
LNPM-1C 1 L 220V / 110V 0.75 kW 70–810 83 kg 750×470×590 30 L
LNPM-2C 2 L 220V / 110V 0.75 kW 70–810 85 kg 750×470×590 30 L
LNPM-4C 4 L 220V / 110V 0.75 kW 70–810 88 kg 750×470×590 50 L
LNPM-6C 6 L 220V / 110V 0.75 kW 70–670 93 kg 750×470×590 50 L
LNPM-8C 8 L 220V / 110V 1.5 kW 70–580 150 kg 880×560×670 50 L
LNPM-10C 10 L 220V / 110V 1.5 kW 70–580 150 kg 880×560×670 100 L
LNPM-12C 12 L 220V / 110V 1.5 kW 70–580 150 kg 880×560×670 100 L

Key Features & Advantages

  • Liquid Nitrogen Cooling with -40°C to 20°C Temperature Range: Continuous liquid nitrogen injection into the insulated chamber rapidly absorbs grinding-generated heat, maintaining the grinding environment at temperatures as low as -40°C for true cryogenic processing of temperature-sensitive materials.
  • Four-Station Simultaneous Grinding with Independent Sample Processing: The standard four-position grinding configuration enables simultaneous preparation of four different samples in a single run, dramatically improving experimental throughput for comparative material studies.
  • Vacuum and Inert Atmosphere Grinding Compatibility: The system supports vacuum grinding jars, enabling inert gas or vacuum atmosphere cryogenic grinding for air-sensitive materials that require complete environmental isolation during processing.
  • Enhanced Capacity with 8 L Total Volume (4 × 2 L): The LNPM-8C features a larger 8 L total volume supporting 4 standard 2 L grinding jars, offering increased sample throughput while maintaining consistent cryogenic temperature control across all jars for small-batch production and pilot-scale applications.

APPLICATION SCOPE: Widely used in geology, mining, metallurgy, electronics, building materials, ceramics, chemical engineering, light industry, pharmaceuticals, and environmental protection for low-temperature grinding. Specifically suitable for electronic ceramics, structural ceramics, magnetic materials, lithium cobalt oxide, lithium manganese oxide, catalysts, phosphors, long-afterglow luminescent powders, rare-earth polishing powders, glass micro-powders, fuel cells, zinc oxide varistors, piezoelectric ceramics, nanopowders, multilayer ceramic capacitors (MLCC), PTC/NTC thermistors, dielectric ceramics, alumina ceramics, zirconia ceramics, zinc oxide powders, cobalt oxide powders, nickel-zinc ferrites, and manganese-zinc ferrites where cryogenic processing is essential.
PACKAGING: This listing is priced for the main unit only. The standard configuration includes 1 pc grinding host machine with liquid nitrogen cooling system and four-station grinding platform. Includes 50 L empty LN2 tank. Grinding jars and grinding balls are ordered separately. The LNPM series is available from 1 L through 12 L models. Compatible with 30 L, 50 L, or 100 L liquid nitrogen storage tanks. Installation guidance and operational training support are provided upon request.
IMPORTANT NOTICE: The listed price is for the main unit; grinding jars and grinding balls must be ordered separately. 50 L liquid nitrogen tank is included with the main unit. Liquid nitrogen consumption is approximately 4–5 L/h under 0–10°C operating conditions. Adequate ventilation is required in the operating area due to nitrogen gas displacement. Always follow cryogenic safety protocols when handling liquid nitrogen. For detailed installation, operation, and maintenance instructions, consult the user manual prior to first use. If you have specific requirements for other LNPM models or custom configurations, please contact us at inquiry@atomfair.com.
TAILORED SOLUTIONS FOR RESEARCH & PRODUCTION
Contact our engineering team for technical support or official quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The LNPM-8C requires a well-ventilated operating area to mitigate nitrogen gas displacement hazards. Liquid nitrogen consumption is approximately 4–5 L/h under 0–10°C conditions, and the system must be connected to a filled 50 L liquid nitrogen tank.

  • Temperature Control: The grinding chamber maintains a temperature range of -40°C to 20°C via continuous liquid nitrogen injection.
  • Ventilation Requirement: Adequate ventilation is required in the operating area due to nitrogen gas displacement from liquid nitrogen cooling.
  • LN2 Tank: The included 50 L empty liquid nitrogen tank must be filled with liquid nitrogen and connected to the mill for operation.
  • Jar Compatibility: Grinding jars and balls are ordered separately and must be compatible with the 4-station 2 L jar configuration.

This procedure outlines the steps to safely set up and operate the LNPM-8C cryogenic ball mill. The system requires proper ventilation, liquid nitrogen supply, and installation of grinding jars and balls.

Required Equipment: 50 L liquid nitrogen tank, Grinding jars (2 L, suitable material), Grinding balls

  1. Ensure ventilation and safety
    Ensure the operating area is well-ventilated and all cryogenic safety protocols are in place.
  2. Connect liquid nitrogen supply
    Fill the 50 L liquid nitrogen tank with liquid nitrogen and connect it to the mill's supply port.
  3. Install grinding jars and balls
    Install the appropriate grinding jars and balls into the four stations, ensuring each jar is properly sealed.
  4. Set parameters and start
    Set the desired temperature and rotation speed on the control panel, then start the grinding process.

Can the LNPM-8C perform cryogenic grinding under inert atmosphere or vacuum conditions?

Yes, the LNPM-8C supports vacuum grinding jars, enabling inert gas or vacuum atmosphere cryogenic grinding for air-sensitive materials. The four-station platform accommodates vacuum jars, and the liquid nitrogen cooling system maintains temperatures as low as -40°C within the insulated chamber, providing complete environmental isolation during processing.

What is the recommended liquid nitrogen supply setup for continuous operation of the LNPM-8C?

The LNPM-8C includes a 50 L empty LN2 tank. Under 0–10°C operating conditions, liquid nitrogen consumption is approximately 4–5 L/h, providing roughly 10–12.5 hours of continuous operation per tank fill. Adequate ventilation is required due to nitrogen gas displacement, and cryogenic safety protocols must be followed.

What jar materials are compatible with the LNPM-8C for cryogenic grinding?

The LNPM-8C accepts 2 L grinding jars made from WC-Co, Al₂O₃, Agate, YSZ, SS, PU, Ceramic, and Nylon. Jars and grinding balls are ordered separately. The choice of jar material depends on sample contamination requirements and abrasion resistance; for example, agate jars are suitable for zero-metal analysis, while WC-Co jars offer high hardness for nano-grinding.

The Atomfair LNPM-8C is a 4-station cryogenic planetary ball mill with 8 L total volume, enabling low-temperature grinding down to -40°C via continuous liquid nitrogen injection, suitable for temperature-sensitive materials in research and small-batch production.

Positive

  • Cryogenic grinding down to -40°C: Continuous liquid nitrogen injection maintains a stable low-temperature environment as low as -40°C, enabling processing of temperature-sensitive materials such as electronic ceramics, battery materials, and pharmaceuticals that degrade under ambient milling conditions.
  • Four-station vacuum/inert atmosphere compatibility: The four grinding stations support vacuum or inert gas grinding jars, permitting simultaneous preparation of up to four different samples under controlled atmosphere conditions for air-sensitive materials without environmental contamination.

Trade-offs

  • Continuous liquid nitrogen supply required: Under 0–10°C operating conditions, liquid nitrogen consumption is approximately 4–5 L/h, necessitating a reliable LN2 supply (50 L tank included but must be refilled) and cryogenic handling infrastructure for sustained operation.
  • Ventilation and cryogenic safety protocols mandatory: Nitrogen gas displacement from liquid nitrogen boil-off requires adequate ventilation in the operating area to prevent oxygen depletion, and all standard cryogenic safety procedures must be followed during setup and operation.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Weight 150 kg
Dimensions 88 × 56 × 67 cm
Combinations

Main Unit, Main Unit +4 Al₂O₃ Jars & Media, Main Unit +4 YSZ Jars & Media, Main Unit +4 Agate Jars & Media