|
160L Mid-Humidity (20%-60% RH) Stainless Steel Damp-Proof Cabinet
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
This cabinet requires stable indoor placement and level installation to ensure proper door sealing and humidity control. Users must confirm stable power conditions, avoid exceeding shelf-loading limits, and keep the door closed during normal operation to maintain performance.
- Post-Delivery Inspection: Inspect the cabinet after delivery for any visible damage or defects.
- Level Installation: Verify that the cabinet is placed on a stable, level surface and that the door seals properly.
- Power Supply Confirmation: Confirm that the power supply is stable and meets the cabinet's requirements before formal use.
- Shelf Loading Limit: Do not exceed the stated shelf-loading capacity to prevent damage or imbalance.
- Door Closure During Operation: Keep the cabinet door closed during normal use to maintain the controlled humidity environment.
Follow these steps to properly install and operate the cabinet for optimal humidity-controlled storage. Ensure the cabinet is placed correctly and all conditions are met before use.
- Inspect Cabinet
Inspect the cabinet after delivery for any visible damage or defects. - Position Cabinet
Place the cabinet on a stable, level indoor surface that can support its weight. - Verify Level and Sealing
Verify that the cabinet is level and that the door seals completely when closed. - Connect Power
Confirm stable power conditions and connect the cabinet to an appropriate power source. - Load Shelves
Distribute stored items evenly across the three adjustable shelf levels to avoid overloading. - Close Door
Keep the cabinet door closed during normal operation to maintain humidity control. - Protect During Movement
Protect structural and sealing components when moving the cabinet to prevent damage.
How does the power-off memory feature of the microcomputer control maintain humidity setpoints after a power interruption?
The microcomputer intelligent control includes power-off memory, which retains the last configured humidity setpoint in non-volatile memory. After a power failure, the cabinet resumes operation automatically with the same settings, eliminating the need for manual reconfiguration and ensuring consistent humidity management.
Can the 160L stainless steel damp-proof cabinet be integrated with PC monitoring or gas-purging accessories?
Yes, the cabinet supports optional accessories including an RS485 communication interface for PC-side monitoring and recorded cabinet-status management, as well as a gas-filling device for faster dehumidification or clean-gas purging. These options extend the cabinet's functionality for advanced laboratory or clean-room workflows.
What installation and operational conditions are required to ensure optimal performance of the SUS304 damp-proof cabinet?
The cabinet must be placed on a stable indoor surface with the door kept closed during normal operation. Stored items should be evenly distributed across the three adjustable shelves. Before use, verify level installation and door sealing, and confirm stable power conditions. For shipment, reinforced wooden-crate packaging is recommended to protect structural and sealing components.
The Atomfair 160L Mid-Humidity Stainless Steel Damp-Proof Cabinet (model AF-SSDC160A) provides a SUS304 stainless steel storage environment with electronic dehumidification maintaining 20%-60% RH, suitable for clean-room and corrosion-sensitive materials, but limited to mid-humidity range and requires optional upgrades for RS485 monitoring.
Positive
- SUS304 stainless steel cabinet body: The cabinet is constructed from SUS304 stainless steel, offering corrosion resistance and clean-room compatibility for hygiene-sensitive and corrosion-conscious storage environments.
- Microcomputer control with power-off memory: The control system retains settings after power loss and includes an over-humidity alarm, ensuring reliable operation and safety without manual reconfiguration.
Trade-offs
- Mid-humidity range only (20%-60% RH): The dehumidification is limited to 20%-60% RH, making it unsuitable for applications requiring ultra-low humidity below 20% RH.
- Optional RS485 for monitoring: PC-side monitoring and recorded cabinet-status management require an optional RS485 communication interface, not included in the base configuration.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).






