Description
160L Mid-Humidity (20%-60% RH) Dry CabinetsDry storage cabinet, mid-humidity control
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
CONTROLLED DRY STORAGE SOLUTIONS
For volume selection, humidity grade confirmation or optional configuration, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The cabinet requires upright transport and level placement to ensure proper door sealing and dehumidification operation. Stable power supply must be provided and the cabinet should be kept closed during normal use to maintain humidity control.
- Transport Restriction: The cabinet must be kept upright during transport and moved with suitable lifting equipment to prevent internal damage.
- Level Placement: The cabinet must be placed on a level surface to ensure proper door sealing and consistent dehumidifier function.
- Door Sealing: The door must be closed securely during operation to maintain the internal humidity set point and prevent ambient ingress.
- Power Requirement: The cabinet requires a stable power supply; power interruption will retain set points but may affect humidity recovery time.
This procedure outlines the initial installation and preparation steps for the dry cabinet. Follow these steps to ensure proper humidity control and safe storage of sensitive materials.
Required Equipment: Lifting equipment
- Transport to Site
Transport the cabinet upright with reinforced outer protection to the installation location. - Level the Cabinet
Place the cabinet on a level surface and adjust the leveling feet to ensure stable and even positioning. - Connect Power
Connect the cabinet to a stable power source and verify the LCD display shows humidity and temperature readings. - Stabilize and Load
Close the door securely and allow the cabinet to reach the set humidity range before loading sensitive materials.
How does the ±3% RH accuracy of the Honeywell sensor in the Atomfair AF-DC160A dry cabinet affect long-term reliability for storing moisture-sensitive components?
The Honeywell sensor provides ±3% RH accuracy with only 0.3% annual drift as stated in the specifications. This ensures consistent measurement over years without frequent recalibration. However this model's mid-humidity range of 20%-60% RH may not be suitable for materials requiring tighter control below 20% RH; lower-humidity grade models are available separately.
Can the Atomfair AF-DC160A dry cabinet be integrated into an existing cleanroom or inert-atmosphere workflow?
Yes. The cabinet offers optional accessories including an RS485 PC logging interface for real-time data logging and remote monitoring as described in optional accessories. A nitrogen purge system with fast-purge gas valve supports accelerated dehumidification and inert-atmosphere management. For cleanroom use an ESD-safe anti-static coating compliant with IEC 61340-5 is available. These options must be specified at order time.
What infrastructure requirements must be met before placing moisture-sensitive materials into the Atomfair AF-DC160A dry cabinet?
After installation confirm level placement of the cabinet door sealing integrity via magnetic gasket shelf loading capacity on perforated adjustable shelves and stable power supply before storing sensitive materials as per handling requirements. The microcomputer retains set-point after power interruption but extended power loss could allow humidity rise; optional over-humidity alarm system triggers if internal humidity exceeds set point as noted in optional accessories.
The AF-DC160A 160L mid-humidity dry cabinet provides automatic electronic dehumidification with a Honeywell sensor for 20%-60% RH control, suitable for general moisture-sensitive storage but not for ultra-dry applications requiring sub-20% RH.
Positive
- Consumable-free dehumidification: Automatic electronic dehumidification module eliminates the need for disposable desiccant, reducing ongoing maintenance and operational costs.
- High-accuracy humidity sensing: Honeywell temperature and humidity sensor provides ±3% RH accuracy with only 0.3% annual drift, ensuring reliable long-term measurement for controlled storage.
Trade-offs
- Limited to mid-humidity range: The cabinet maintains 20%-60% RH and cannot achieve ultra-low or extreme-low humidity levels, restricting its use to materials that tolerate moderate moisture conditions.
- Handling and installation constraints: The cabinet must be transported upright with reinforced protection and requires level placement after installation to ensure proper door sealing and stable operation.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).