1435L-4 Mid-Humidity (20%-60% RH) Dry CabinetsDry storage cabinet, mid-humidity control
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
CONTROLLED DRY STORAGE SOLUTIONS
For volume selection, humidity grade confirmation or optional configuration, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The cabinet must be transported upright with reinforced protection and kept level during installation. Stable power and minimal door openings are required to maintain set humidity and prevent material exposure.
- Transport Orientation: Transport the cabinet upright and use reinforced outer protection and suitable lifting equipment to prevent structural damage.
- Level Placement: Place the cabinet on a level surface and confirm door sealing and shelf loading before storing sensitive materials.
- Power Stability: Connect the cabinet to a stable power source to ensure continuous operation and set-point memory after power interruption.
- Door Sealing: Keep the cabinet door closed during normal use and minimize extended ambient exposure to maintain the controlled internal humidity.
- Humidity Confirmation: Confirm the target humidity grade and optional accessories before ordering, and validate the storage process for ultra-low humidity applications.
Install the cabinet on a level surface and connect to stable power before setting the humidity. Allow the cabinet to stabilize and minimize door openings to maintain the controlled environment.
Required Equipment: Suitable lifting equipment
- Transport and Position
Transport the cabinet upright with reinforced outer protection and suitable lifting equipment to the installation site. - Level and Secure
Place the cabinet on a level surface and adjust as needed to ensure door sealing and stable shelf loading. - Connect Power
Connect the cabinet to a stable power source and verify the LCD display shows real-time humidity, temperature, and operating status. - Set Humidity
Configure the desired humidity set point using the microcomputer control; the set point is retained after power interruption. - Stabilize Environment
Allow the cabinet to run until the internal humidity stabilizes at the set point before placing moisture-sensitive materials inside. - Load Materials
Place materials on adjustable shelves, ensuring uniform air circulation and avoiding overloading beyond shelf capacity. - Maintain Closure
Keep the cabinet door closed during normal use and open only briefly to retrieve or store items to minimize humidity fluctuation.
How does the ±3% RH accuracy of the Honeywell sensor affect long-term reliability for mid-humidity storage?
The Honeywell sensor provides ±3% RH accuracy with only 0.3% annual drift. This ensures consistent measurement over years without recalibration. For mid-humidity (20%-60% RH), this accuracy is sufficient to prevent moisture-related damage like oxidation or solderability loss without requiring ultra-dry conditions.
Can this dry cabinet be integrated into an existing laboratory monitoring system for real-time humidity tracking?
Yes. The optional RS485 PC logging interface enables real-time data logging and remote monitoring of cabinet humidity and temperature status. This allows integration with laboratory management systems for traceability. Additionally an over-humidity alarm option can trigger alerts when internal humidity exceeds set points.
What are the critical installation requirements for maintaining stable humidity control in this dry cabinet?
The cabinet must be transported upright with reinforced outer protection. After installation confirm level placement door sealing shelf loading and stable power before storing sensitive materials. Keep the cabinet door closed during normal use to minimize ambient exposure which could compromise humidity stability.
The Atomfair AF-DC1435A-4 is a 1435L mid-humidity dry cabinet with automatic electronic dehumidification and Honeywell sensing, suitable for controlled storage of moisture-sensitive materials in labs and workshops, but limited to 20%-60% RH range and requiring careful handling due to its size.
Positive
- No disposable desiccant consumables: The automatic electronic dehumidification module eliminates the need for replacement desiccants, reducing ongoing maintenance and consumable costs.
- High-precision Honeywell sensor: The integrated Honeywell temperature and humidity sensor provides ±3% RH accuracy with 0.3% annual drift, ensuring reliable long-term measurement for stable storage conditions.
Trade-offs
- Mid-humidity range limitation: The cabinet controls humidity only within 20%-60% RH; materials requiring ultra-low or extreme-low humidity (below 20% RH) necessitate a different model or optional nitrogen purge system.
- Large cabinet handling requirements: With outer dimensions of 1200 x 700 x 1860 mm and a volume of 1435L, the cabinet must be transported upright with reinforced protection and moved using suitable lifting equipment; level placement and stable power are required after installation.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).