Description
160L Dual-Flow Energy-Saving Nitrogen CabinetResearch-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The cabinet requires a stable, level indoor surface and a reliable nitrogen gas supply with flow rates within the specified large-flow (15-50 L/min) and small-flow (1-5 L/min) ranges. Stored moisture-sensitive materials must be evenly distributed across shelves, and the cabinet door must remain sealed during normal operation to maintain the 1%-60% RH humidity control range.
- Installation Requirement: Install the cabinet on a stable, level indoor surface and verify that the door seals properly before use.
- Gas Supply Constraint: Ensure a stable nitrogen gas supply with flow rates not exceeding the large-flow meter setting of 15-50 L/min or small-flow setting of 1-5 L/min.
- Load Distribution: Distribute stored items evenly across the three adjustable shelves to avoid overloading and maintain airflow circulation.
- Operational Sealing: Keep the cabinet door closed during normal use to preserve the low-humidity atmosphere and minimize unnecessary nitrogen consumption.
- Handling During Transport: Protect structural and sealing components during movement and use reinforced wooden-crate packaging for shipment protection.
The setup involves inspecting the delivered cabinet, installing it on a stable level surface, and connecting a nitrogen gas supply with appropriate flow rates. After verifying door sealing and even distribution of stored materials, the cabinet automatically manages humidity control through dual-flow switching.
- Inspect Cabinet
Inspect the cabinet after delivery for any damage and verify that all components are present. - Position Cabinet
Position the cabinet on a stable, level indoor surface and ensure it is not tilted. - Connect Gas Supply
Connect a nitrogen gas supply to the cabinet inlet and set the large-flow meter to 15-50 L/min and small-flow meter to 1-5 L/min as needed. - Distribute Materials
Distribute moisture-sensitive materials evenly across the three adjustable shelves to maintain airflow. - Close and Confirm
Close the cabinet door securely and confirm that the humidity control system maintains the set range (1%-60% RH) through automatic switching.
How does the dual-flow nitrogen system balance fast humidity recovery with reduced nitrogen consumption in the 160 L cabinet?
The 160 L Dual-Flow Energy-Saving Nitrogen Cabinet uses automatic software-controlled switching between a large-flow meter setting of 15-50 L/min and a small-flow meter setting of 1-5 L/min. After a door opening, the high-flow stage accelerates atmosphere recovery, then the system automatically reverts to low-flow operation to minimize unnecessary nitrogen use. This logic is explicitly designed to improve recovery speed while lowering routine nitrogen demand, as stated in the product's operating characteristics.
Can the 160 L Dual-Flow Nitrogen Cabinet be used for storage of optical components and what humidity range must be maintained?
Yes, the cabinet is designed for moisture-sensitive materials including optical components, as listed in the suitable stored materials. The humidity control range is 1%-60% RH, and the cabinet maintains a low-humidity nitrogen-assisted environment with tempered-glass viewing doors and perforated adjustable shelves for airflow. The dual-flow system helps restore the cabinet atmosphere quickly after door openings, which is critical for frequently accessed optical storage spaces.
What are the gas supply and installation requirements for the 160 L Dual-Flow Nitrogen Cabinet?
The cabinet must be installed on a stable indoor surface with the door kept closed during normal use, and stored items should be evenly distributed across the three adjustable shelves. The handling notice emphasizes verifying stable gas-supply conditions before operation and confirming utility conditions such as power and gas connections before formal use. The cabinet uses automatic software-controlled nitrogen management with large-flow (15-50 L/min) and small-flow (1-5 L/min) meter settings, so a regulated nitrogen source with appropriate flow capacity is required.
The 160L Dual-Flow Energy-Saving Nitrogen Cabinet provides automatic switching between large-flow (15-50 L/min) and small-flow (1-5 L/min) operation, enabling rapid humidity recovery after door opening while minimizing nitrogen consumption, making it well-suited for frequently accessed low-humidity storage of moisture-sensitive parts in research and electronics laboratories.
Positive
- Dual-flow nitrogen management with automatic switching: Automatically switches between large-flow (15-50 L/min) and small-flow (1-5 L/min) modes to achieve fast humidity recovery after door opening while reducing unnecessary nitrogen consumption, ideal for frequently accessed storage applications.
- Sealed steel cabinet with tempered-glass doors: Constructed from 1.2 mm galvanized steel with magnetic sealing and 5 mm tempered-glass viewing doors, ensuring a robust, low-leakage enclosure for stable low-humidity atmosphere control.
Trade-offs
- Dependence on external nitrogen supply: The cabinet requires a continuous, stable external nitrogen source to maintain low-humidity conditions; verifying gas supply and pressure is essential before operation, and nitrogen consumption must be budgeted for recurring use.
- Standard cabinet lacks ESD or corrosion protection: The base model features a standard white galvanized steel body; for electrostatic-sensitive or corrosive environments, optional anti-static coating or stainless steel upgrades are required, adding cost and lead time.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).