160L Ultra-Low-Humidity Dry Cabinet 1%-10% RH ATOMFAIR®

$1,070.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

160L ultra-low-humidity dry cabinet with 1%-10% RH control, Honeywell ±3% RH sensor, 450 × 450 × 1010 mm galvanized steel body and 3 shelves. Order now.

SKU: AF-EI-E-DC00-USTD-160L
Category:
Brands:

Description

160L Ultra-Low-Humidity (1%-10% RH) Dry Cabinets

Dry storage cabinet, ultra-low-humidity control

Product Overview

The Atomfair DC-Series AF-DC160C is a 160L dry cabinet configured for 1%-10% RH relative humidity control, with a standard white cabinet body, outer dimensions of 450 x 450 x 1010 mm, inner dimensions of 405 x 420 x 840 mm, and 3 adjustable shelves.

This model provides ultra-low-humidity storage for MSDs, IC packages, optical devices and polymers that can degrade quickly after moisture exposure. It is used to prevent moisture absorption, oxidation, micro-structural degradation, optical haze, solderability loss and other humidity-related damage during storage, inspection, production staging or long-term preservation.

Application scenarios include SMT and semiconductor component rooms, optoelectronic cleanrooms, precision optical workshops, research laboratories, industrial quality-control centers, polymer or film storage, and technical archives for moisture-sensitive assets.

The cabinet integrates automatic electronic dehumidification, high-precision Honeywell temperature and humidity sensing, a digital LCD display for humidity, temperature, operating status and fault information, set-point memory after power interruption, tempered-glass viewing doors, reinforced adjustable shelves and sealed cabinet construction for repeatable daily operation.

Specifications

1. Selected Model & Dimension Parameters
Model Cabinet Body Volume Humidity Grade Humidity Range Outer Size Inner Size Shelf Count
AF-DC160C Standard white powder-coated steel body 160L Ultra-Low-Humidity 1%-10% RH 450 x 450 x 1010 mm 405 x 420 x 840 mm 3
2. Technical Specifications
Parameter Details
Cabinet Body Standard white powder-coated steel body
Humidity Control Range 1%-10% RH
Temperature Display Range 0-99°C
Humidity Display Range 0%-99% RH
Sensor Honeywell temperature and humidity sensor, ±3% RH accuracy and 0.3% annual drift
Display High-definition LCD display for humidity, temperature, operation status and fault codes
Dehumidification System Automatic electronic dehumidification module with no disposable desiccant consumables
Control Mode Microcomputer automatic control with set-point memory after power interruption
Structure 1.2 mm galvanized steel cabinet, 5 mm tempered glass viewing door, magnetic sealing gasket and lockable handle

Key Features and Advantages

  • Selectable humidity grades are split into individual models: A mid-humidity 20%-60% RH, B low-humidity 10%-20% RH, C ultra-low-humidity 1%-10% RH and D extreme-low-humidity 1%-3% RH, allowing the cabinet to match the actual sensitivity of stored materials.
  • High-precision sensing uses a Honeywell temperature and humidity sensor with ±3% RH accuracy and low annual drift for reliable long-term measurement.
  • Efficient automatic dehumidification removes moisture rapidly, requires no disposable desiccant consumables and supports continuous operation with minimal maintenance.
  • Intelligent microcomputer control retains set parameters after power loss and shows real-time humidity, temperature, operating status and fault codes on the LCD display.
  • Robust sealed construction uses a galvanized steel cabinet body, tempered safety glass, double-frame sealing, magnetic gaskets and a lockable handle for stable dry storage.
  • Perforated adjustable shelves support uniform air circulation and make it easier to store components, instruments and samples of different sizes.

Optional Accessories

  • ESD-Safe Anti-Static Coating: Provides electrostatic protection for ESD-controlled production and storage areas, compliant with IEC 61340-5 handling requirements.
  • Internal LED Illumination: Moisture-resistant interior lighting improves visibility when checking stored parts, labels and shelf positions.
  • Premium Stainless-Steel Body: High-grade structural body option for cleanrooms, corrosive environments or facilities with stricter hygiene requirements.
  • Nitrogen Purge System: Fast-purge gas valve configuration supports accelerated dehumidification and inert-atmosphere management.
  • RS485 PC Logging Interface: Enables real-time data logging, remote monitoring and traceability of cabinet humidity and temperature status.
  • Over-Humidity Alarm System: Microcomputer alarm function is triggered when the internal humidity exceeds the configured set point.
For tailored configurations or formal technical quotations regarding these options, please contact our engineering team.
APPLICATION SCOPE: Engineered for research laboratories, cleanroom environments, semiconductor assembly lines, SMT component rooms, optical workshops and high-tech industrial quality-control centers managing moisture-sensitive electronic, optical, chemical and archival assets.
HANDLING REQUIREMENT: The cabinet should be transported with reinforced outer protection, kept upright, and moved with suitable lifting or handling equipment according to its volume. After installation, confirm level placement, door sealing, shelf loading and stable power before storing sensitive materials.
IMPORTANT NOTICE: Confirm the exact capacity, humidity grade, cabinet body type and optional accessories before ordering. Keep the cabinet door closed during normal use and minimize extended ambient exposure of sensitive materials. For ultra-low or extreme-low humidity applications, validate the storage process before formal production use and consider nitrogen purge or alarm options when process risk is high.
CONTROLLED DRY STORAGE SOLUTIONS
For volume selection, humidity grade confirmation or optional configuration, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This cabinet requires upright transport and level installation with confirmed door sealing and stable power before storing moisture-sensitive materials. The storage environment must maintain closed-door operation and minimize ambient exposure to preserve ultra-low humidity conditions.

  • Transport Constraint: The cabinet must be transported upright with reinforced outer protection using suitable lifting equipment.
  • Installation Constraint: Level placement, door sealing, and shelf loading must be confirmed before storing sensitive materials.
  • Power Constraint: Stable power connection is required, and set-point memory is retained after power interruption.
  • Operational Constraint: The cabinet door must remain closed during normal use, and extended ambient exposure of stored materials should be minimized.
  • Validation Requirement: For ultra-low or extreme-low humidity applications, the storage process must be validated before formal production use.

Follow these steps to install, configure, and validate the dry cabinet for moisture-sensitive material storage. Proper handling ensures stable humidity control and prevents damage to stored items.

Required Equipment: Lifting equipment

  1. Transport the cabinet
    Transport the cabinet upright using suitable lifting equipment to avoid structural damage.
  2. Place and level the cabinet
    Place the cabinet on a level surface and confirm door sealing with the magnetic gasket.
  3. Load shelves with materials
    Load shelves with materials, ensuring uniform air circulation through perforated shelves.
  4. Connect power and verify display
    Connect the cabinet to a stable power supply and verify the LCD display shows correct humidity and temperature.
  5. Set the humidity range
    Set the desired humidity range using the microcomputer control and confirm set-point memory after power loss.
  6. Validate ultra-low humidity operation
    For ultra-low humidity operation, validate the storage process by monitoring initial humidity decline.
  7. Maintain closed-door operation
    Keep the cabinet door closed during normal operation and minimize exposure to ambient conditions.

How does the Honeywell sensor's ±3% RH accuracy and 0.3% annual drift affect long-term reliability of ultra-low humidity storage in the Atomfair DC160C?

The Honeywell sensor provides ±3% RH accuracy, which is sufficient for maintaining the 1%-10% RH target range, but the 0.3% annual drift means recalibration may be needed after extended use to prevent gradual set-point deviation. The sensor's low drift ensures stable readings over typical maintenance intervals, though for extreme-low humidity applications (1%-3% RH), a dedicated model grade (D) with tighter control is recommended. The digital LCD displays real-time humidity and temperature, supporting regular verification against external standards.

Can the Atomfair DC160C dry cabinet be integrated with existing cleanroom monitoring or data logging systems for semiconductor component storage?

Yes, the cabinet offers an optional RS485 PC logging interface that enables real-time data logging and remote monitoring of humidity and temperature, supporting traceability in semiconductor and optoelectronic cleanrooms. Additionally, an over-humidity alarm option triggers when internal RH exceeds the set point, and the nitrogen purge system allows inert-atmosphere management for ultra-low humidity requirements. The ESD-safe anti-static coating option complies with IEC 61340-5 for ESD-sensitive environments.

What installation and handling procedures are critical for achieving stable 1%-10% RH performance with the DC160C in a laboratory or SMT facility?

The cabinet must be transported upright with reinforced outer protection and placed on a level surface to ensure proper door sealing and magnetic gasket contact. After setup, confirm level placement, door seal integrity, and stable power before loading moisture-sensitive components. Minimize door openings to prevent humidity spikes, and for high-risk processes, consider the nitrogen purge or over-humidity alarm options. The automatic dehumidification system requires no consumables, but the Honeywell sensor's calibration drift (0.3% annually) should be monitored for long-term accuracy.

The Atomfair AF-DC160C 160L dry cabinet delivers ultra-low humidity control (1%-10% RH) via automatic electronic dehumidification with no consumable desiccants, paired with a Honeywell sensor offering ±3% RH accuracy and low drift. Operational deployment requires careful upright transport, level installation, door seal verification, and process validation before use in critical ultra-low-humidity applications.

Positive

  • Consumable-free dehumidification: Automatic electronic dehumidification module eliminates the need for disposable desiccant consumables, reducing ongoing maintenance and operational cost.
  • High-accuracy Honeywell sensor: Honeywell temperature and humidity sensor provides ±3% RH accuracy with only 0.3% annual drift, ensuring reliable long-term measurement for sensitive storage.

Trade-offs

  • Transport and installation sensitivity: Cabinet must be transported upright with reinforced outer protection, and after installation requires confirmation of level placement, door sealing, shelf loading, and stable power before use.
  • Process validation for ultra-low humidity: For ultra-low or extreme-low humidity applications, the storage process must be validated before formal production use; nitrogen purge or alarm options are recommended when process risk is high.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).