|
320L Ultra-Low-Humidity (1%-10% RH) Stainless Steel Damp-Proof Cabinet
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The cabinet requires installation on a stable, level surface with stable power supply to ensure proper dehumidification function. The door must remain closed during normal operation and stored items must be distributed evenly across shelves to maintain humidity control and prevent structural overload.
- Installation Requirements: Install the cabinet on a stable indoor surface and confirm stable power conditions before formal use.
- Operational Constraints: Keep the door closed during normal use and distribute stored items evenly across the three shelf levels to avoid overloading.
- Handling Precautions: Protect structural and sealing components during movement to prevent damage that could compromise humidity control.
- Shipping Requirements: Use reinforced wooden-crate packaging when shipment protection is required.
- Post-Delivery Inspection: Inspect the cabinet after delivery and verify level installation and door sealing before use.
Install the cabinet on a stable level surface with stable power and verify proper door sealing before use. Distribute stored items evenly and keep the door closed during normal operation to maintain the low-humidity environment.
Required Equipment:
- Inspect the cabinet
Inspect the cabinet after delivery for any damage and verify that the door seals properly. - Position the cabinet
Place the cabinet on a stable, level indoor surface and confirm it is not tilted. - Connect to power
Confirm stable power conditions and connect the cabinet to the power source. - Load items
Distribute stored items evenly across the three adjustable shelves to avoid exceeding shelf-loading limits. - Operate the cabinet
Close the door securely and keep it closed during normal operation to maintain the set humidity range.
How does the 320L ultra-low-humidity cabinet maintain 1%-10% RH without desiccants or refrigerants?
The cabinet uses a high-efficiency electronic dehumidification device controlled by a microcomputer intelligent system with power-off memory, enabling rapid humidity reduction to the 1%-10% RH range without consumable desiccants or refrigerant-based systems. This electronic approach is suitable for continuous, maintenance-free operation in clean-room environments.
Can the Atomfair AF-SSDC320C cabinet be integrated with external monitoring systems for clean-room compliance?
Yes, the cabinet supports an optional RS485 communication interface for PC-side monitoring and recorded cabinet-status management, as well as an optional over-humidity alarm device that triggers when measured humidity exceeds the configured set value. These options allow integration into central clean-room monitoring and alerting systems.
What are the installation and operational requirements for the 320L stainless steel damp-proof cabinet in a clean-room environment?
Install the cabinet on a stable indoor surface, ensure level placement and proper door sealing, and distribute stored items evenly across the three adjustable shelves. During movement, protect structural and sealing components; for shipment, use reinforced wooden-crate packaging. Confirm stable power conditions before use. The SUS304 stainless steel body and tempered-glass doors are designed for clean-room, hygiene-sensitive, and corrosion-conscious storage.
The 320L stainless steel damp-proof cabinet provides humidity control from 1% to 10% RH using a SUS304 cabinet and a high-efficiency electronic dehumidifier, with microcomputer intelligent control including power-off memory and over-humidity alarm support for clean-room and moisture-sensitive storage applications.
Positive
- SUS304 stainless steel construction: The cabinet body is made of SUS304 stainless steel, providing durability and corrosion resistance suitable for clean-room, hygiene-sensitive, and corrosion-conscious storage environments.
- Precise low-humidity control with memory: The microcomputer intelligent control system maintains a humidity range of 1%-10% RH and retains settings after power loss via power-off memory, ensuring consistent storage conditions.
Trade-offs
- Requires stable power and installation: Stable power conditions must be confirmed before use, and the cabinet requires level installation on a stable indoor surface to maintain proper door sealing and humidity control performance.
- Optional accessories require separate inquiry: Features like gas-filling device, RS485 communication interface, and over-humidity alarm device are optional and must be requested via consultation, which may delay deployment.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).






