Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

SUS304 stainless steel nitrogen cabinet with 1435 L capacity, 1%-60% RH control, 1200 × 700 × 1860 mm body, 5 shelves and over-humidity alarm. Order now.

SKU: AF-EI-E-SSNC-STD0-14L3
Category:
Brands:

1435L-6 Stainless Steel Nitrogen Cabinet

Research-grade laboratory product

Product Overview

The 1435 L configuration uses a SUS304 stainless steel cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 1200 × 700 × 1860 mm, inner dimensions of 1155 × 650 × 1680 mm and 5 adjustable shelves. The 1435 L layout uses a three-door cabinet.

This stainless steel nitrogen cabinet is intended for clean storage applications that require a nitrogen-controlled low-humidity atmosphere together with a stainless steel cabinet body. It helps reduce moisture absorption, oxidation and long-term storage drift in sensitive materials while lowering gas consumption compared with ordinary nitrogen cabinet operation.

Typical application areas include clean laboratories, electronics production rooms, optical storage environments, semiconductor handling areas and inspection spaces that require organized low-humidity nitrogen-assisted storage. This body type is suitable for clean-room-oriented, hygiene-sensitive and corrosion-conscious storage environments.

The cabinet combines SUS304 stainless steel cabinet construction with tempered-glass viewing doors and clean-room-oriented surface durability, a precision nitrogen-control device, microcomputer intelligent control with power-off memory, over-humidity alarm support and adjustable shelf storage for dependable cabinet management.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-SSNC1435-6
Product Family Stainless Steel Nitrogen Cabinet
Cabinet Body SUS304 stainless steel cabinet body
Nominal Capacity 1435 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 1200 × 700 × 1860 mm
Inner Dimensions (W × D × H) 1155 × 650 × 1680 mm
Adjustable Shelf Quantity 5
Door Configuration Three-door cabinet
Cabinet Material SUS304 stainless steel cabinet structure with tempered-glass viewing doors
Control Mode Microcomputer intelligent control with power-off memory
Nitrogen Control Device Precision nitrogen-control device
Nitrogen Saving Performance Designed to reduce gas consumption by about 50% compared with ordinary nitrogen cabinets
Alarm Function Over-humidity alarm support
Suitable Stored Materials Clean-room materials, electronics, optical components, semiconductor parts and sensitive laboratory items

Key Features and Advantages

  • SUS304 stainless steel cabinet body for clean-room-oriented storage environments.
  • Precision nitrogen-control device designed to reduce gas consumption by about 50% compared with ordinary nitrogen cabinets.
  • Microcomputer intelligent control with power-off memory and automatic operation.
  • Over-humidity alarm configuration for safety-focused cabinet management.
  • Adjustable shelves support organized storage of clean materials, electronics, optics and other sensitive items.

Optional Items and Consultation

  • Electronic dehumidification module that can operate together with the gas-filling unit to reduce nitrogen use.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for clean laboratories, electronics production rooms, optical storage environments, semiconductor handling areas and inspection spaces that require organized low-humidity nitrogen-assisted storage.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 5 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This cabinet requires a stable indoor surface and a continuous nitrogen gas supply to maintain the 1%–60% RH humidity range. Proper installation includes leveling, door seal verification, and even weight distribution across five adjustable shelves to prevent structural stress.

  • Installation Environment: Install the cabinet on a stable, level indoor surface away from direct sunlight or corrosive atmospheres.
  • Gas Supply: Connect a clean, dry nitrogen source to the precision control device and verify stable gas-supply conditions before operation.
  • Loading Constraint: Distribute stored items evenly across the five shelves and do not exceed the stated shelf-loading capacity.
  • Handling and Transport: Protect structural and sealing components during movement and use reinforced wooden-crate packaging for shipment.
  • Utility Verification: Confirm power and gas connections are correct before formal use; the microcomputer control has power-off memory but requires initial setup.

Follow these steps to prepare the cabinet for storing sensitive materials under a controlled low-humidity nitrogen atmosphere. Ensure the cabinet is placed in the intended location before proceeding.

Required Equipment:

  1. Inspect the Cabinet
    Inspect the cabinet after delivery to check for any damage to the body, doors, or seals.
  2. Position and Level
    Place the cabinet on a stable, level indoor surface and verify it is level using a spirit level.
  3. Connect Nitrogen Supply
    Connect the nitrogen gas supply to the precision control device and ensure the gas pressure is within the operating range.
  4. Set Humidity Level
    Set the desired humidity level (1%–60% RH) using the microcomputer control panel.
  5. Load Shelves
    Distribute stored items evenly across the five adjustable shelves without exceeding the loading limit.
  6. Close and Seal Doors
    Close the doors and verify the tempered-glass doors seal properly against the cabinet body.
  7. Monitor Alarm Indicator
    Monitor the over-humidity alarm indicator to confirm the cabinet maintains the set humidity.

Does the 1435L-6 stainless steel nitrogen cabinet's nitrogen-saving design trade off humidity control accuracy or response time?

No, the precision nitrogen-control device and microcomputer intelligent control maintain a humidity control range of 1%–60% RH while reducing gas consumption by about 50% compared with ordinary nitrogen cabinets. The system also includes over-humidity alarm support for safety, with no specified degradation in control accuracy or response time.

Can the 1435L-6 cabinet be integrated with an on-site nitrogen generator or an electronic dehumidification module for enhanced performance?

Yes, optional items include an electronic dehumidification module that operates together with the gas-filling unit to reduce nitrogen use, as well as a nitrogen generator configuration for on-site nitrogen supply. The cabinet also supports an RS485 communication interface for PC-side monitoring and an over-humidity alarm device.

What installation, handling, and infrastructure requirements must be met for safe operation of the 1435L-6 stainless steel nitrogen cabinet?

The cabinet must be installed on a stable indoor surface, kept closed during normal use, and loaded evenly across its 5 adjustable shelves. Verify stable gas-supply conditions before operation, confirm power and gas connections, and do not exceed stated shelf-loading or application conditions. Over-humidity alarm support provides added safety if humidity exceeds the set value.

The 1435L-6 Stainless Steel Nitrogen Cabinet (AF-SSNC1435-6) offers a large 1435 L SUS304 stainless steel storage volume with precision nitrogen control that reduces gas consumption by approximately 50% relative to standard nitrogen cabinets, suitable for clean-room, optical, and semiconductor storage requiring controlled low-humidity atmospheres.

Positive

  • SUS304 stainless steel construction: Cabinet body and structure are made from SUS304 stainless steel, providing clean-room-compatible hygiene, corrosion resistance, and surface durability for sensitive storage environments.
  • Up to 50% nitrogen gas savings: The precision nitrogen-control device is designed to reduce gas consumption by about 50% compared with ordinary nitrogen cabinets, lowering operational costs and gas usage over the storage lifetime.

Trade-offs

  • Requires stable nitrogen supply: The cabinet depends on an external, regulated nitrogen source for low-humidity operation; users must verify stable gas-supply conditions and connections before use.
  • Requires careful installation handling: The large 1435 L cabinet must be installed on a level, stable indoor surface, and its weight and dimensions necessitate reinforced wooden-crate packaging and protection of sealing components during transport and setup.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).