Stainless Steel Damp-Proof Cabinet 450L 1%-10% RH ATOMFAIR®

$2,800.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

SUS304 stainless damp-proof cabinet with 450 L capacity, 1%-10% RH control, 900 × 600 × 1010 mm outer size and 3 adjustable shelves. Order now.

SKU: AF-EI-E-SSDC-USTD-450L
Category:
Brands:

450L Ultra-Low-Humidity (1%-10% RH) Stainless Steel Damp-Proof Cabinet
Research-grade laboratory product
Product Overview

The 450 L configuration uses a SUS304 stainless steel cabinet body, a humidity control range of 1%-10% RH, outer dimensions of 900 × 600 × 1010 mm, inner dimensions of 855 × 570 × 840 mm and 3 adjustable shelves.

This stainless steel damp-proof cabinet is designed for clean-room-oriented storage where a durable cabinet body and controlled low-humidity conditions are preferred. It provides humidity-managed storage for clean materials, moisture-sensitive components, archived items and routine laboratory samples while helping reduce moisture-related surface change and storage drift.

Typical application areas include clean-room-oriented laboratories, electronics workshops, optical storage rooms, technical archives, powder and film storage areas and quality-control spaces that require organized dry protection. This body type is suitable for clean-room-oriented, hygiene-sensitive and corrosion-conscious storage environments.

The cabinet combines SUS304 stainless steel cabinet construction with tempered-glass viewing doors and clean-room-oriented surface durability, a high-efficiency electronic dehumidification device, microcomputer intelligent control with power-off memory, over-humidity alarm support and adjustable shelf storage for dependable day-to-day use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-SSDC450C
Product Family Stainless Steel Damp-Proof Cabinet
Cabinet Body SUS304 stainless steel cabinet body
Nominal Capacity 450 L
Humidity Grade Ultra-Low-Humidity
Humidity Control Range 1%-10% RH
Outer Dimensions (W × D × H) 900 × 600 × 1010 mm
Inner Dimensions (W × D × H) 855 × 570 × 840 mm
Adjustable Shelf Quantity 3
Cabinet Material SUS304 stainless steel cabinet structure with tempered-glass viewing doors
Control Mode Microcomputer intelligent control with power-off memory
Dehumidification Device High-efficiency electronic dehumidification device
Alarm Function Over-humidity alarm support
Suitable Stored Materials Clean-room materials, electronics, optics, archived documents, powders, films and routine laboratory samples
Key Features and Advantages
  • SUS304 stainless steel cabinet body for clean-room-oriented and hygiene-sensitive storage environments.
  • High-efficiency electronic dehumidification device for rapid cabinet humidity reduction.
  • Microcomputer intelligent control with power-off memory and fully automatic running logic.
  • Over-humidity alarm configuration for safety-focused cabinet operation.
  • Adjustable shelf layout supports orderly storage of clean materials, electronics, optics and routine laboratory items.
Optional Items and Consultation
  • Gas-filling device for faster dehumidification or clean-gas purging support.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for clean-room-oriented laboratories, electronics workshops, optical storage rooms, technical archives and dry-protection environments that require organized low-humidity storage with a stainless steel cabinet body.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 3 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required.
IMPORTANT NOTICE: Please note that the listed price covers the product only; shipping costs must be requested via inquiry.Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm stable power conditions before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The cabinet maintains a humidity range of 1%-10% RH and must be installed on a stable, level surface. Over-humidity alarm triggers when measured humidity exceeds the set value; do not exceed shelf-loading capacity or application conditions.

  • Environmental Humidity Range: Maintain 1%-10% RH for optimal storage; continuous operation outside this range may trigger alarm.
  • Installation Surface: Install on a stable indoor surface to prevent tipping and ensure proper sealing.
  • Shelf Loading: Distribute stored items evenly across the three adjustable shelves without exceeding the rated shelf-loading capacity.
  • Power Conditions: Confirm stable power conditions before formal use; power-off memory retains settings.
  • Door Sealing: Keep the door closed during normal use and verify door sealing after installation to maintain humidity control.

Follow these steps to set up the cabinet for dry storage of moisture-sensitive materials. Proper installation and loading ensure optimal humidity control and equipment longevity.

  1. Install the cabinet
    Install the cabinet on a stable indoor surface to ensure level positioning and structural integrity.
  2. Inspect and verify
    Inspect the cabinet after delivery to verify level installation and door sealing.
  3. Confirm power supply
    Confirm stable power conditions before connecting the cabinet to the electrical outlet.
  4. Load materials
    Distribute stored items evenly across the three adjustable shelf levels without exceeding the rated shelf-loading capacity.
  5. Maintain operation
    Keep the door closed during normal operation to maintain the internal humidity level within the control range.

Can the 450L stainless steel damp-proof cabinet be equipped with an RS485 interface for remote monitoring and data logging?

Yes, the 450L cabinet supports an optional RS485 communication interface for PC-side monitoring and recorded cabinet-status management. This allows integration into laboratory monitoring systems for real-time humidity tracking and data logging.

What are the critical installation steps to ensure the cabinet maintains its 1%-10% RH specification?

Install the cabinet on a stable, level indoor surface. After delivery, verify level installation and door sealing. Keep the door closed during normal use and distribute stored items evenly across the three adjustable shelves. Protect structural and sealing components during movement.

What is the function of the microcomputer intelligent control with power-off memory in the AF-SSDC450C?

The microcomputer intelligent control with power-off memory automatically retains the configured humidity setpoint and operational parameters after a power interruption. Upon power restoration, the cabinet resumes operation without manual reconfiguration, ensuring consistent humidity control.

This 450L stainless steel damp-proof cabinet provides ultra-low-humidity storage (1%-10% RH) with SUS304 construction and intelligent control, ideal for clean-room and moisture-sensitive materials, though requiring careful installation and handling.

Positive

  • SUS304 stainless steel construction: The cabinet body is made of SUS304 stainless steel, providing durability and corrosion resistance suitable for clean-room and hygiene-sensitive storage environments.
  • Precise humidity control with alarm: The microcomputer intelligent control system maintains humidity from 1% to 10% RH with power-off memory and over-humidity alarm support for reliable, safe storage.

Trade-offs

  • Installation and leveling requirements: The cabinet must be installed on a stable indoor surface and properly leveled to ensure door sealing and consistent humidity control; shelf loading must be evenly distributed to avoid structural stress.
  • Shipping and handling sensitivity: The stainless steel cabinet requires reinforced wooden-crate packaging for shipment and careful handling to protect structural and sealing components during movement, adding logistical complexity.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).