Programmable Climate Chamber, 150 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
Operate the chamber only within the specified ambient temperature and humidity limits to ensure safe performance. When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C; when set above 40°C, humidity setpoints should not exceed 80%.
- Ambient Temperature Limit for Low Set Point: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C to prevent cooling system overload.
- Humidity Limit for High Set Point: When the set temperature is above 40°C, humidity setpoints should generally not exceed 80% to avoid condensation or component stress.
- Stable Room Temperature Requirement: Maintain a stable room temperature and avoid direct heat sources near the chamber for consistent operation.
- Upright Transport Requirement: Keep the chamber upright during unloading and positioning to prevent damage to the refrigeration system.
- Power Supply and Grounding: Connect the chamber to a grounded AC220V 50Hz power supply and verify the power cord is intact before operation.
Position the chamber on a stable, level surface away from heat sources and ensure ambient temperature is within the recommended range. Connect the chamber to a grounded power supply and confirm all accessories are installed correctly.
Required Equipment: Accessory package
- Inspect and Position
Position the chamber upright on a stable surface away from direct heat sources, ensuring stable room temperature. - Install Accessories
Confirm the selected accessory package is installed correctly before connecting power. - Connect Power
Connect the chamber to a grounded AC220V 50Hz power supply. - Program Parameters
Program the desired temperature, humidity, and light parameters using the LCD controller. - Monitor Operation
Monitor the chamber's self-diagnosis and over-temperature limiting functions during operation.
What are the limitations on humidity control when operating at high temperatures in the AF-QHX150T climate chamber?
When the temperature setpoint is above 40°C, humidity setpoints should generally not exceed 80%RH. This operational constraint is stated in the product specifications and is based on no-load testing at 20°C and 50%RH ambient conditions, ensuring reliable chamber performance.
Can the AF-QHX150T climate chamber be used for low-temperature experiments requiring temperatures below 10°C?
Yes, the chamber can operate in no-light mode from 5°C to 60°C. However, when the set temperature is 10°C or below, the ambient temperature must not exceed 26°C, as stated in the configuration notes. This ambient temperature constraint is critical for achieving and maintaining low setpoints reliably.
What power and placement requirements are needed for the 150 L programmable climate chamber (model AF-QHX150T)?
The chamber requires 600 W input on an AC220V 50Hz power supply. It should be placed away from direct heat sources with stable room temperature. The external dimensions are 652 x 655 x 1420 mm and net weight is 82.5 kg; ensure adequate floor space and that the unit remains upright during transport and positioning.
The Atomfair AF-QHX150T programmable climate chamber offers 150 L capacity with temperature control from 5-60°C (no light) or 10-60°C (illuminated), humidity from 50-90%RH, and illumination up to 10000 lux across six levels, making it suitable for plant growth, tissue culture, and microbial incubation. However, operational constraints include a ±2°C temperature uniformity, ±8%RH humidity deviation, and environmental dependencies: at low setpoints ambient temperature must be ≤26°C, and at high temperatures humidity should not exceed 80%.
Positive
- Programmable climate simulation: LCD microcomputer-controlled temperature, humidity, light intensity, and time allow repeatable simulated natural climate conditions for plant growth, tissue culture, and seed germination experiments.
- Top lighting and visible inner door: Top-mounted illumination with 0-10000 lux (6 levels) and a tempered-glass inner door support unobstructed observation during photoperiod studies, while the mirror-finish stainless-steel chamber facilitates cleaning and corrosion resistance.
Trade-offs
- Temperature and humidity operating limits: When set temperature is ≤10°C, ambient temperature must not exceed 26°C; when set temperature is >40°C, humidity should generally not exceed 80%RH. These constraints require careful lab environment management.
- Moderate uniformity and deviation: Temperature uniformity is ±2°C and humidity deviation is ±8%RH, which may be insufficient for applications requiring tighter environmental control, such as precise pharmaceutical stability testing or sensitive material conditioning.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.