150L Humidified Mold Incubator AF-HI150-MJ15H ATOMFAIR®

$3,800.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

150 L humidified mold incubator with 15-45°C / 10-45°C control, 60-85% RH humidity, 0.1°C resolution, 680 W input, and 3 shelves.

SKU: AF-LE-E-HMOL-0150-H15I
Category:
Tags: , ,
Brands:

150L Humidified Mold Incubator, 15-45℃ / 10-45℃ Temperature Control Range
Research-grade laboratory product
Product Overview

150L Humidified Mold Incubator, 15-45℃ / 10-45℃ Temperature Control Range is designed for humidity-sensitive fungal culture, mold observation, spore germination, environmental simulation, and moisture-dependent microbiology work. With a nominal capacity of 150 L and a temperature range of 15-45℃ / 10-45℃, it supports controlled handling of cultures, fungal samples, microorganisms, preserved materials, and other laboratory test loads.

The cabinet layout is defined by the chamber size is 550×405×670mm, overall dimensions are 690×800×1430mm, the standard shelf setup is 3 shelves, input power is 680 W, the power supply is AC220V 50Hz. These dimensions and electrical requirements help laboratories plan bench-side placement, floor-standing installation, teaching use, quality inspection, research sample staging, and repeated daily workflows.

Temperature performance includes 0.1°C temperature resolution, high temp ±0.5°C; low temp ±1.0°C fluctuation control, ±1.5°C to ±2.5°C at 25°C temperature uniformity, a humidity range of 60 to 85% RH, humidity deviation of ±5 to 8% RH, a timer range of 0 to 5999 min. The working chamber uses Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading. This construction supports regular loading, cleaning, observation, and repeated operation where stable environmental conditions are important.

Control options are shown as AF-HI150-MJ15H: Liquid-crystal display controller. Optional functions may include an embedded printer, RS485 communication, USB data transfer, independent over-temperature alarm protection, multi-segment programmable control, and UV sterilization for applicable mold configurations. Accessory availability and custom chamber-size requirements can be checked by e-mail before ordering.

Product Specifications
Parameter Specification
Product Type Humidified Mold Incubator
Nominal Capacity 150 L
Atomfair Models AF-HI150-MJ15H
Temperature Range 15-45℃ / 10-45℃
Temperature Resolution 0.1°C
Temperature Fluctuation high temp ±0.5°C; low temp ±1.0°C
Temperature Uniformity ±1.5°C to ±2.5°C at 25°C
Humidity Range 60 to 85% RH
Humidity Deviation ±5 to 8% RH
Input Power 680 W
Power Supply AC220V 50Hz
Ambient Temperature +5 to 30°C
Chamber Size 550×405×670mm
Overall Dimensions 690×800×1430mm
Shelves 3 shelves
Timer 0 to 5999 min
Inner Chamber and Insulation Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading.
Controller Configuration AF-HI150-MJ15H: Liquid-crystal display controller
Optional Accessories Optional embedded printer or RS485 communication interface for recording temperature changes; USB data transfer for selected configurations; Independent over-temperature alarm system where supported; Multi-segment programmable controller for selected control configurations; UV sterilization system, standard or optional depending on the selected mold configuration. Some accessories may be non-stock and require lead time; email for availability and quotation.
Key Points and Advantages
  • 0.1°C temperature resolution supports finer setpoint adjustment, which is helpful for routine cultivation, preservation, and method repeatability.
  • The published fluctuation level of high temp ±0.5°C; low temp ±1.0°C helps users maintain steadier chamber conditions during day-to-day experimental cycles.
  • Temperature uniformity of ±1.5°C to ±2.5°C at 25°C helps reduce position-related differences inside the chamber, which is valuable when multiple vessels are loaded at once.
  • Humidity-control capability expands the product’s usefulness for moisture-sensitive fungal work and other tasks where temperature control alone is not sufficient.
  • The published shelf configurations help laboratories organize flasks, bottles, trays, and routine test loads more flexibly within the available chamber volume.
  • Optional accessories can include embedded printers, RS485 communication, USB data transfer, independent over-temperature alarm support, multi-segment programmable control, and mold-series UV sterilization where applicable.
  • If a configuration needs a different chamber size or accessory package, the quotation can be adjusted by e-mail before order confirmation.
APPLICATION SCOPE: Suitable for humidity-sensitive fungal culture, mold observation, spore germination, and environmental simulation work where both temperature and moisture levels influence growth behavior and test repeatability.
PACKAGING: The equipment is prepared with protective inner cushioning, reinforced outer packaging, and transport-oriented structural support to help reduce vibration and handling impact during storage and delivery. Export reinforcement or other packing adjustments can be discussed when project quantity, route, or receiving conditions require it.
IMPORTANT NOTICE: Please confirm the exact configuration, installation footprint, power supply, accessory package, and delivery arrangement before ordering. If a custom chamber size is required, please contact us by e-mail for quotation and availability review.
LABORATORY PROCUREMENT SUPPORT
For model selection, specification comparison, accessory review, or quotation support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Manufacturer: Atomfair LLC

Brand: ATOMFAIR®

This document defines the environmental and operational boundaries for the 150L humidified mold incubator, independent of its performance specifications. Operators should apply these constraints when installing, loading, and maintaining the chamber for humidity-sensitive culture work.

  • Electrical supply constraint: Connect the incubator only to the specified power supply type and rated input power.
  • Ambient environment constraint: Operate the incubator only within the ambient temperature range stated in the product documentation.
  • Loading and access constraint: Arrange culture vessels on the removable shelves to permit safe loading, observation, and routine cleaning access.
  • Chamber hygiene constraint: Clean the mirror stainless-steel inner chamber and rounded-corner transitions after humid culture use to limit residue accumulation.
  • Over-temperature safety constraint: If the optional independent over-temperature alarm protection is installed, confirm it is active before starting long-duration mold cultures.

This procedure describes the initial setup and routine operation of the 150L humidified mold incubator using its liquid-crystal display controller and available recording accessories. Follow these steps only after confirming the electrical supply, ambient conditions, and installed options match the product documentation.

Required Equipment: Liquid-crystal display controller, Optional embedded printer or RS485 interface

  1. Verify installation conditions
    Confirm the incubator is connected to the specified power supply and placed within the ambient temperature range stated in the product documentation.
  2. Set chamber parameters
    Set the required temperature and humidity values on the liquid-crystal display controller before loading samples.
  3. Start the incubator
    Start the incubation cycle and allow the chamber to reach the selected temperature and humidity setpoints before introducing cultures.
  4. Load samples
    Load humidity-sensitive cultures onto the removable shelves using the adjusted shelf supports.
  5. Monitor conditions
    Monitor displayed conditions during the cycle and use the optional embedded printer or RS485 interface to record temperature changes when installed.
  6. Clean after operation
    Clean the mirror stainless-steel chamber and rounded-corner transitions after completing humid culture work.

How does the temperature uniformity of the 150L humidified mold incubator vary across the operating range, and what is the expected fluctuation at high versus low temperature setpoints?

Temperature uniformity is specified as ±1.5°C to ±2.5°C at 25°C; the source does not provide uniformity data at other setpoints. Temperature fluctuation is ±0.5°C at high temp (15–45°C range) and ±1.0°C at low temp (10–45°C range), indicating tighter control at higher setpoints. These values help assess positional consistency when multiple vessels are loaded.

What data logging and communication options are available for the AF-HI150-MJ15H controller, and how can they be integrated into a laboratory monitoring system?

The liquid-crystal display controller supports optional embedded printer, RS485 communication interface, and USB data transfer for selected configurations. These allow recording temperature changes and exporting data; the RS485 interface enables integration with centralized monitoring systems. Availability should be confirmed via email before ordering.

What are the ambient temperature and power supply requirements for installing this humidified mold incubator, and what safety features protect against over-temperature conditions?

The incubator requires an ambient temperature of +5 to 30°C and a power supply of AC220V 50Hz with 680W input. An independent over-temperature alarm system is available as an optional accessory, providing protection against temperature runaway. The mirror stainless-steel inner chamber with rounded corners facilitates cleaning and contamination control.

The 150L Humidified Mold Incubator (model AF-HI150-MJ15H) provides a controlled environment with a temperature range of 15-45°C and humidity from 60-85% RH, specifically designed for fungal culture and moisture-sensitive microbiology. Its mirror stainless-steel chamber with rounded corners facilitates cleaning and reduces contamination risk, while optional accessories like RS485 and USB data transfer support data logging for reproducibility.

Positive

  • Integrated humidity control for fungal work: The 60-85% RH humidity range with ±5 to 8% deviation directly supports moisture-dependent applications such as spore germination and mold observation, where temperature-only incubators are insufficient.
  • Stainless-steel chamber with rounded corners: Mirror stainless-steel interior with rounded-corner transitions and removable shelf supports reduces contamination risk and simplifies cleaning, critical for maintaining sterile conditions in fungal and microbiological cultures.

Trade-offs

  • Temperature uniformity varies with setpoint: Temperature uniformity ranges from ±1.5°C to ±2.5°C at 25°C, which may cause position-dependent growth variations when the chamber is fully loaded with multiple vessels, requiring careful sample placement.
  • Humidity deviation range impacts precision: Humidity deviation of ±5 to 8% RH means actual chamber humidity may vary up to 16% across cycles, potentially affecting experiments requiring tight moisture control, such as standardized spore germination assays.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).