150L Multi-Chamber Dual-Chamber Biochemical Incubator, 0-60°C
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, specification comparison, accessory review, or quotation support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
The incubator requires an ambient temperature range of +5 to 30°C and a stable AC220V 50Hz power supply to maintain specified performance. The mirror stainless-steel inner chamber with rounded-corner transitions supports routine cleaning but requires careful handling to avoid surface damage during loading.
- Temperature Uniformity Constraint: Temperature uniformity of ±1°C at 25°C may degrade if the chamber is overloaded or if door openings are frequent, potentially affecting sample consistency.
- Power Supply Requirement: The 2200 W input power requires a dedicated circuit to prevent tripping when both chambers operate simultaneously.
- Optional UV Sterilization Constraint: UV sterilization, if installed, must only be activated when the chamber is empty to prevent UV exposure to biological samples or personnel.
This procedure covers initial setup, temperature programming, and daily operation for routine biochemical incubation. Follow these steps to ensure stable chamber conditions and avoid common operational errors.
Required Equipment: Liquid-crystal display controller (AF-BI150-2BOX), Power supply cable (AC220V 50Hz), Shelf adjustment tool (if required)
- Verify Installation Environment
Confirm the ambient temperature is between +5 and 30°C and the power outlet supplies stable AC220V 50Hz before connecting the unit. - Set Temperature Parameters
Use the liquid-crystal display controller to set the desired temperature within the 0-60°C range, adjusting resolution to 0.1°C as needed. - Configure Timer if Required
Set the timer from 0 to 5999 minutes on the controller to automate incubation duration or enable timed shutdown. - Load Samples Evenly
Distribute flasks or trays across the three shelves per chamber to maintain ±1°C uniformity and avoid blocking airflow. - Monitor Chamber Conditions
Check the displayed temperature fluctuation (high temp ±0.5°C; low temp ±0.5°C) periodically to confirm stable operation. - Clean Inner Chamber After Use
Wipe the mirror stainless-steel surfaces with a non-abrasive cleaner to prevent residue buildup and maintain rounded-corner integrity.
How does the 0.1°C temperature resolution and ±0.5°C fluctuation control support method repeatability in biochemical incubation?
The 0.1°C resolution allows finer setpoint adjustment, and the ±0.5°C fluctuation helps maintain steadier chamber conditions during experimental cycles. These specifications support routine cultivation and preservation by reducing temperature variability.
What electrical and ambient conditions are required for reliable operation of the 150L dual-chamber incubator?
The incubator requires an AC220V 50Hz power supply with 2200W input power. Ambient temperature must be maintained between +5°C and 30°C. These conditions ensure stable temperature control and prevent performance degradation.
Is an independent over-temperature alarm available for this incubator, and how does it integrate with the main controller?
An independent over-temperature alarm system is available as an optional accessory where supported. It provides additional protection beyond the primary liquid-crystal display controller. For integration details and availability, contact the manufacturer.
The 150L dual-chamber biochemical incubator provides independent temperature control in two chambers, enabling parallel incubation or comparative studies without cross-contamination. Temperature fluctuation of ±0.5°C and uniformity of ±1°C at 25°C support reproducible conditions for routine cultivation and preservation, while the 0.1°C resolution allows fine setpoint adjustment.
Positive
- Dual-chamber design for parallel workflows: Two independent 150L chambers allow simultaneous incubation of different sample sets, reducing door-opening interference and enabling comparative batch studies within a single unit.
- Fine temperature resolution and stability: 0.1°C resolution with ±0.5°C fluctuation and ±1°C uniformity at 25°C supports reproducible conditions for routine cultivation, preservation, and method repeatability.
Trade-offs
- Narrow ambient temperature range: The unit requires an ambient temperature of +5 to 30°C for proper operation, limiting placement to climate-controlled laboratory environments without additional cooling.
- High power consumption for capacity: At 2200 W input power for a 150L total capacity, the energy demand is relatively high, which may impact operational costs and require dedicated electrical circuits in shared lab spaces.