150L Intelligent Biochemical Incubator, -5-70°C
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, specification comparison, accessory review, or quotation support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
The incubator requires an ambient temperature range of +5 to 35°C and a stable AC220V 50Hz power supply for proper operation. The mirror stainless-steel inner chamber with rounded-corner transitions supports routine cleaning but requires careful handling to avoid surface damage during loading.
- Temperature Uniformity Constraint: Temperature uniformity of ±1.5°C at 25°C may cause position-related differences when multiple vessels are loaded simultaneously.
- Power Supply Requirement: The unit draws 850 W input power and must be connected to a dedicated AC220V 50Hz circuit to prevent electrical instability.
- Timer Range Limitation: The programmable timer operates from 0 to 5999 minutes, limiting extended unattended runs beyond this duration.
This procedure covers initial setup, programming, and safe operation of the incubator for routine biochemical incubation. Follow these steps to configure temperature programs and verify chamber conditions before loading samples.
Required Equipment: Intelligent touch-screen controller (AF-BI150-BPC15T), AC220V 50Hz power supply
- Verify power and ambient conditions
Confirm the incubator is connected to a stable AC220V 50Hz power source and the ambient temperature is between +5 and 35°C. - Set temperature program via touch-screen
Use the intelligent touch-screen controller to select one of eight program groups and configure up to eight steps with temperature setpoints and durations from 0 to 5999 minutes. - Enable auto-start or standby functions
Preset auto-start, standby, or shutdown functions on the controller to automate the incubation cycle. - Lock touch-screen to prevent unauthorized changes
Activate the touch-screen lock after programming to prevent accidental operation by unauthorized users. - Load samples onto shelves evenly
Place flasks, bottles, or trays on the three adjustable shelves, ensuring even distribution to minimize temperature uniformity variations. - Monitor chamber conditions during operation
Observe the real-time temperature display on the controller and verify that fluctuation remains within high temp ±0.3°C or low temp ±0.5°C as applicable.
Why does the temperature fluctuation specification differ between high and low temperature ranges on the 150L biochemical incubator?
The incubator specifies high temperature fluctuation at ±0.3°C and low temperature fluctuation at ±0.5°C because the refrigeration system's performance varies at lower setpoints, a common characteristic of units with both heating and cooling. This is explicitly stated in the product specifications for the AF-BI150-BPC15T model.
Can the Atomfair 150L biochemical incubator be integrated with external data logging or monitoring systems?
Yes, optional accessories include an embedded printer, RS485 communication interface, and USB data transfer for recording temperature changes. These options allow integration with external logging systems, but availability should be confirmed by email before ordering as some may require lead time.
What ambient temperature range is required for proper operation of this -5 to 70°C incubator?
The incubator requires an ambient temperature range of +5 to 35°C for proper operation. Operating outside this range may affect temperature control performance or cause condensation issues, as specified in the product's environmental requirements.
The Atomfair 150L Intelligent Biochemical Incubator delivers 0.1°C resolution and ±0.3/0.5°C fluctuation with a multi-stage programmable touch-screen controller supporting 8 groups of up to 8 steps each, suitable for routine incubation, BOD, and sample preservation. However, it requires AC220V 50Hz power and ambient conditions between 5-35°C, and optional accessories may be non-stock with lead times.
Positive
- Fine temperature resolution and fluctuation: 0.1°C resolution and ±0.3°C (high temp)/±0.5°C (low temp) fluctuation support finer setpoint adjustment and steadier chamber conditions for routine cultivation and preservation.
- Multi-stage programmable controller: Intelligent touch-screen controller with 8 program groups of up to 8 steps each and auto start/standby/shutdown enables gradient temperature ramping and timed protocols without manual intervention.
Trade-offs
- Ambient temperature dependency: Unit requires ambient temperature of +5 to 35°C for proper operation, limiting installation in unconditioned or hot environments without additional climate control.
- Optional accessory lead time: Add-ons such as embedded printer, RS485, USB, or UV sterilization may be non-stock and require advanced ordering; availability and lead time must be confirmed by email before purchase.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).