150 L Biochemical Incubator 0-50°C LCD 600 W ATOMFAIR®

$1,100.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 150 L biochemical incubator with 0–50°C PID control, ±1°C accuracy, 136 L effective capacity, LCD timing to 9999 min. Order now.

150L General Biochemical Incubator with 0-50°C Temperature Control Range
Research-grade laboratory product
Product Overview

150L General Biochemical Incubator with 0-50°C Temperature Control Range is designed for microbiology culture work, sample holding, routine incubation and steady low-temperature laboratory processing where clear control and stable cabinet conditions matter in daily use.

This 150 L model combines microcomputer temperature control, an LCD display, a stainless-steel working chamber, removable shelves and a magnetic door seal in a clean cabinet structure that supports repeatable operation and convenient observation during laboratory workflows.

The chamber size is 420 x 500 x 650 mm, the external size is 655 x 665 x 1265 mm, and the rated power is 600 W. The 0-50 C temperature control range supports bacteria and mold culture, microorganism preservation, water analysis, BOD-related work, plant cultivation and other temperature-managed laboratory tasks described for this product family.

The cabinet is intended for research institutes, university laboratories, public health work, pharmaceutical inspection, environmental analysis and other technical settings that need a practical incubator with straightforward daily operation, visible status display and an interior layout that is easy to organize and clean.

When the set temperature is below 10 C, ambient temperature should be below 26 C.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-BI150-T50
Nominal Capacity 150 L
Effective Capacity 136 L
Temperature Control Range 0 to 50 C
Temperature Control Accuracy +/-1 C
Temperature Uniformity +/-2 C
Display Mode LCD display
Timing Range 0 to 9999 min
Power Supply AC 220 V, 50 Hz
Rated Power 600 W
Working Chamber Size 420 x 500 x 650 mm
Overall Dimensions 655 x 665 x 1265 mm
Net Weight 70 kg
Shelf Configuration 2 standard shelves
Chamber Material Stainless-steel working chamber
Exterior Finish Coated cabinet exterior
Ambient Condition Note When set temperature is below 10 C, ambient temperature should be below 26 C.
Performance Features
  • Microcomputer control with LCD display allows operators to view set temperature, current temperature and timing status directly, improving day-to-day monitoring efficiency.
  • PID temperature control helps reduce fluctuation during operation, which is useful for culture storage, incubation consistency and routine repeatability.
  • The 0-50 C temperature control range gives this model flexibility for low-temperature storage, constant-temperature holding and general biochemical incubation workflows.
  • The 150 L chamber size supports routine sample batches without making the cabinet unnecessarily large for standard benchside or floor-standing laboratory use.
  • Stainless-steel chamber construction supports cleanliness, corrosion resistance and easier interior maintenance after repeated laboratory use.
  • Removable shelves make it easier to adjust internal layout for bottles, flasks, culture containers and other routine laboratory items.
  • The magnetic door sealing structure improves closing convenience and chamber tightness, helping reduce unnecessary disturbance during operation.
  • The inner door structure and visual observation design help users check chamber conditions more conveniently while reducing frequent full-door opening.
  • Built-in timing from 0 to 9999 min supports scheduled operation and reduces the need for continuous manual supervision.
  • The circulation fan and air-duct structure described for this series help improve chamber temperature uniformity, which is beneficial for more consistent incubation conditions across the usable space.
  • Functions such as self-diagnosis, over-temperature limit support and power-failure memory help strengthen operational reliability in routine laboratory environments.
APPLICATION SCOPE: Suitable for bacteria and mold culture, microorganism preservation, BOD-related work, water analysis, plant cultivation, breeding tests, sample holding and other laboratory workflows that require controlled temperature management in research, teaching, inspection and technical support environments.
PACKAGING: The equipment is prepared with protective inner materials and reinforced outer packaging to improve cushioning, stability and handling protection during storage, transfer and delivery. Additional reinforcement measures can be arranged according to order quantity and transport conditions.
IMPORTANT NOTICE: Please confirm nominal capacity, installation size, power supply and required configuration before quotation. Freight is quoted separately and the listed price does not include freight. When the set temperature is below 10 C, ambient temperature should be below 26 C. If custom dimensions or special configuration are required, contact our technical sales team by e-mail.
LABORATORY PROCUREMENT SUPPORT
For model selection, capacity matching, power supply confirmation or configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Manufacturer: Atomfair LLC

Brand: ATOMFAIR®

This incubator requires the ambient temperature to be below 26°C when the set temperature is below 10°C. Adherence to this constraint ensures stable temperature control and prevents cooling system overload.

  • Ambient Temperature Limitation: When the set temperature is below 10°C, the ambient temperature must be maintained below 26°C to ensure proper operation and avoid performance degradation.

What is the effective usable capacity of the 150L biochemical incubator and why does it differ from the nominal capacity?

The effective capacity is 136 L, while the nominal capacity is 150 L. The difference accounts for internal structures such as the circulation fan, air ducts, and shelf supports that occupy space, ensuring uniform temperature distribution across the usable chamber.

What ambient temperature conditions are required when operating the incubator at setpoints below 10°C?

When the set temperature is below 10°C, the ambient temperature must be below 26°C to maintain stable low-temperature control. This is a critical installation requirement for cold storage applications, as stated in the product specifications.

What safety and reliability features are built into the Atomfair AF-BI150-T50 incubator?

The incubator includes self-diagnosis, over-temperature limit support, and power-failure memory functions to enhance operational reliability. Additionally, the magnetic door seal and inner observation door reduce temperature disturbance during access, supporting consistent incubation conditions.

The Atomfair 150L General Biochemical Incubator (AF-BI150-T50) provides a 0-50°C range with ±1°C accuracy and ±2°C uniformity, suitable for microbiology culture, BOD analysis, and low-temperature sample holding. Its stainless-steel chamber, PID control, and magnetic door seal support routine lab workflows, though ambient temperature must be held below 26°C when operating below 10°C setpoint.

Positive

  • Broad 0-50°C temperature range: Flexible for low-temperature storage (e.g., microorganism preservation) and routine incubation (bacteria/mold culture, BOD work), covering diverse biochemical and environmental analysis protocols without requiring separate units.
  • Stainless-steel chamber with circulation fan: Corrosion-resistant 304-grade stainless steel interior combined with forced air circulation improves temperature uniformity across the 150L workspace, reducing gradients that could compromise experimental repeatability.

Trade-offs

  • Ambient temperature constraint near 0°C: When set temperature is below 10°C, ambient room temperature must be ≤26°C; otherwise, the cooling system cannot maintain setpoint, requiring climate-controlled lab space for low-temperature applications.
  • Single-voltage power supply: Rated for AC 220 V, 50 Hz only, limiting deployment in labs with 110 V or 60 Hz mains without a step-down transformer or frequency converter, which may affect cooling compressor performance.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).