1000L Large-Capacity Biochemical Incubator, 0-60°C
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, specification comparison, accessory review, or quotation support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
The unit requires an ambient temperature range of +5 to 30°C and a stable AC220V 50Hz power supply to maintain specified performance. Temperature uniformity of ±2.5°C at 25°C and fluctuation of high temp ±0.5°C; low temp ±1.0°C are achievable only within these environmental limits.
- Power Supply Constraint: The incubator must be connected to a dedicated AC220V 50Hz circuit with sufficient capacity for the 2150 W input power to avoid voltage drop or tripping.
- Ambient Temperature Constraint: Operate the unit only in a laboratory environment maintained between +5 and 30°C to prevent compressor strain or inaccurate temperature control.
- Over-Temperature Protection: An independent over-temperature alarm system is available as an optional accessory to mitigate risk of thermal runaway during unattended operation.
Position the unit on a level, vibration-free floor with at least 15 cm clearance on all sides for ventilation. Connect to a stable AC220V 50Hz power source and allow the chamber to stabilize at the setpoint before loading samples.
Required Equipment: Leveling feet adjustment tool, Multi-meter for power verification
- Position the Incubator
Place the unit on a level, non-flammable surface with adequate clearance for airflow and door swing. - Connect Power Supply
Verify the power cord is securely connected to a grounded AC220V 50Hz outlet rated for at least 2150 W. - Set Temperature Parameters
Use the controller interface to set the desired temperature within the 0-60°C range and confirm the resolution of 0.1°C. - Allow Stabilization
Wait at least 30 minutes after the chamber reaches setpoint to ensure temperature uniformity of ±2.5°C at 25°C. - Load Samples
Arrange vessels on the stainless-steel shelves, ensuring no obstruction of internal air circulation. - Set Timer if Required
Program the timer from 0 to 5999 minutes for timed incubation cycles using the controller menu.
How does the temperature fluctuation of the 1000L biochemical incubator differ between high and low temperature setpoints?
The temperature fluctuation is ±0.5°C at high temperatures and ±1.0°C at low temperatures, as specified in the product specifications. This means stability is tighter when operating above ambient, while low-temperature operation (down to 0°C) has a wider fluctuation band. Users should account for this when planning experiments near the lower end of the range.
What communication and data logging options are available for integrating this incubator with external monitoring systems?
Optional accessories include an embedded printer, RS485 communication interface, and USB data transfer for selected configurations. These allow recording temperature changes and connecting to laboratory information systems. Availability should be confirmed by email before ordering, as some accessories may require lead time.
What are the critical installation requirements for the 1000L biochemical incubator regarding power supply and ambient conditions?
The incubator requires an AC220V 50Hz power supply with an input power of 2150W (or 2900W depending on configuration). The ambient temperature must be maintained between +5°C and 30°C for proper operation. The overall dimensions are 870x1220x2065mm, so floor-standing installation with adequate clearance is necessary.
The Atomfair 1000L Biochemical Incubator (models AF-BI1000-LRH10F/L) offers a 0-60°C range with ±0.5°C high-temperature and ±1.0°C low-temperature fluctuation control, suited for large-volume biochemical incubation and sample preservation; however, its ±2.5°C uniformity at 25°C and 2150-2900 W power draw impose constraints on position-sensitive assays and laboratory electrical infrastructure.
Positive
- 0.1°C temperature resolution: The 0.1°C resolution enables fine setpoint adjustment for routine cultivation, preservation, and method repeatability, supporting application precision.
- Mirror stainless-steel interior with rounded corners: The mirror stainless-steel inner chamber with rounded-corner transitions and removable shelf supports facilitates easier cleaning and loading, reducing contamination risk in repeated use.
Trade-offs
- Uniformity ±2.5°C at 25°C: The temperature uniformity of ±2.5°C at 25°C may cause position-dependent temperature differences when multiple vessels are loaded simultaneously, requiring careful sample placement for assays sensitive to thermal gradients.
- High input power requirement: The unit requires 2150 W (standard) or up to 2900 W (with accessories) at AC220V 50Hz, which may necessitate dedicated electrical circuits or infrastructure upgrades in some laboratory settings.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).