Anti-Static Dry Cabinet 160L B Grade 10%-20% RH ATOMFAIR®

$1,060.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

160L anti-static dry cabinet with 10%-20% RH control, Honeywell ±3% RH sensor, LCD status display, 450 × 450 × 1010 mm body and 3 shelves. Order now.

Description

160L Anti-Static Low-Humidity (10%-20% RH) Dry Cabinets

Dry storage cabinet, low-humidity control

Product Overview

The Atomfair DC-Series AF-DC160BF is a 160L anti-static dry cabinet configured for 10%-20% RH relative humidity control, with an anti-static cabinet body, outer dimensions of 450 x 450 x 1010 mm, inner dimensions of 405 x 420 x 840 mm, and 3 adjustable shelves.

This model provides low-humidity storage for moisture-sensitive components that require stronger ambient humidity protection. It is used to prevent moisture absorption, oxidation, micro-structural degradation, optical haze, solderability loss and other humidity-related damage during storage, inspection, production staging or long-term preservation.

Application scenarios include electronics manufacturing lines, SMT component rooms, laboratory sample storage, precision instrument storage, optical workshops, film and powder storage, and industrial quality-control areas requiring lower humidity protection.

The cabinet integrates automatic electronic dehumidification, high-precision Honeywell temperature and humidity sensing, a digital LCD display for humidity, temperature, operating status and fault information, set-point memory after power interruption, tempered-glass viewing doors, reinforced adjustable shelves and sealed cabinet construction for repeatable daily operation.

Specifications

1. Selected Model & Dimension Parameters
Model Cabinet Body Volume Humidity Grade Humidity Range Outer Size Inner Size Shelf Count
AF-DC160BF Anti-static powder-coated steel body 160L Low-Humidity 10%-20% RH 450 x 450 x 1010 mm 405 x 420 x 840 mm 3
2. Technical Specifications
Parameter Details
Cabinet Body Anti-static powder-coated steel cabinet body
Humidity Control Range 10%-20% RH
Temperature Display Range 0-99°C
Humidity Display Range 0%-99% RH
Sensor Honeywell temperature and humidity sensor, ±3% RH accuracy and 0.3% annual drift
Display High-definition LCD display for humidity, temperature, operation status and fault codes
Dehumidification System Automatic electronic dehumidification module with no disposable desiccant consumables
Control Mode Microcomputer automatic control with set-point memory after power interruption
Structure 1.2 mm galvanized steel cabinet, 5 mm tempered glass viewing door, magnetic sealing gasket and lockable handle

Key Features and Advantages

  • Selectable humidity grades are split into individual models: A mid-humidity 20%-60% RH, B low-humidity 10%-20% RH, C ultra-low-humidity 1%-10% RH and D extreme-low-humidity 1%-3% RH, allowing the cabinet to match the actual sensitivity of stored materials.
  • High-precision sensing uses a Honeywell temperature and humidity sensor with ±3% RH accuracy and low annual drift for reliable long-term measurement.
  • Efficient automatic dehumidification removes moisture rapidly, requires no disposable desiccant consumables and supports continuous operation with minimal maintenance.
  • Intelligent microcomputer control retains set parameters after power loss and shows real-time humidity, temperature, operating status and fault codes on the LCD display.
  • Robust sealed construction uses a galvanized steel cabinet body, tempered safety glass, double-frame sealing, magnetic gaskets and a lockable handle for stable dry storage.
  • Perforated adjustable shelves support uniform air circulation and make it easier to store components, instruments and samples of different sizes.

Optional Accessories

  • Internal LED Illumination: Moisture-resistant interior lighting improves visibility when checking stored parts, labels and shelf positions.
  • Premium Stainless-Steel Body: High-grade structural body option for cleanrooms, corrosive environments or facilities with stricter hygiene requirements.
  • Nitrogen Purge System: Fast-purge gas valve configuration supports accelerated dehumidification and inert-atmosphere management.
  • RS485 PC Logging Interface: Enables real-time data logging, remote monitoring and traceability of cabinet humidity and temperature status.
  • Over-Humidity Alarm System: Microcomputer alarm function is triggered when the internal humidity exceeds the configured set point.
For tailored configurations or formal technical quotations regarding these options, please contact our engineering team.
APPLICATION SCOPE: Engineered for research laboratories, cleanroom environments, semiconductor assembly lines, SMT component rooms, optical workshops and high-tech industrial quality-control centers managing moisture-sensitive electronic, optical, chemical and archival assets.
HANDLING REQUIREMENT: The cabinet should be transported with reinforced outer protection, kept upright, and moved with suitable lifting or handling equipment according to its volume. After installation, confirm level placement, door sealing, shelf loading and stable power before storing sensitive materials.
IMPORTANT NOTICE: Confirm the exact capacity, humidity grade, cabinet body type and optional accessories before ordering. Keep the cabinet door closed during normal use and minimize extended ambient exposure of sensitive materials. For ultra-low or extreme-low humidity applications, validate the storage process before formal production use and consider nitrogen purge or alarm options when process risk is high.
CONTROLLED DRY STORAGE SOLUTIONS
For volume selection, humidity grade confirmation or optional configuration, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The cabinet requires a stable power supply and level placement to maintain 10%-20% RH. Door must remain closed during operation to prevent moisture ingress and ensure consistent humidity control.

  • Humidity Sensitivity: Stored materials must not require humidity below 10% RH without additional nitrogen purge or an ultra-low humidity model.
  • Power Interruption: Extended power loss may cause humidity to rise above the set point, requiring re-stabilization before storing sensitive items.
  • Transport Orientation: The cabinet must be transported and kept upright to prevent damage to the dehumidification module.
  • Shelf Loading: Shelf load must be evenly distributed and not exceed the rated capacity to maintain air circulation and structural integrity.
  • Environmental Exposure: Minimize the duration of door openings and ambient exposure to prevent moisture adsorption by stored materials.

This procedure covers initial setup, stabilization, and routine operation of the cabinet for moisture-sensitive storage. Follow these steps to ensure proper humidity control and equipment longevity.

Required Equipment: Suitable lifting equipment

  1. Transport the cabinet
    Transport the cabinet upright using suitable lifting equipment and reinforced protection to prevent damage.
  2. Level the cabinet
    Place the cabinet on a level surface and verify stability using a level tool or by checking that all feet contact the floor evenly.
  3. Connect power
    Connect the cabinet to a stable power source and confirm the LCD display shows operating status and current humidity.
  4. Stabilize humidity
    Allow the cabinet to stabilize at the set humidity range for at least 30 minutes before introducing moisture-sensitive materials.

How does the Honeywell sensor's ±3% RH accuracy and 0.3% annual drift affect long-term humidity control reliability in the Atomfair AF-DC160BF dry cabinet?

The Honeywell sensor provides ±3% RH accuracy with only 0.3% annual drift, ensuring reliable long-term measurement for the 10%-20% RH low-humidity range. This high precision allows the microcomputer control to maintain set-points accurately without frequent recalibration, supporting consistent moisture-sensitive component storage over extended periods.

When storing moisture-sensitive components in a cleanroom, what are the limitations of the standard anti-static powder-coated steel cabinet body of the AF-DC160BF compared to the optional stainless-steel body?

The standard anti-static powder-coated steel body may not be suitable for cleanrooms or corrosive environments; the optional premium stainless-steel body is recommended for cleanrooms, corrosive environments, or facilities with stricter hygiene requirements. The standard body is adequate for general electronics manufacturing and lab storage but should be upgraded when particle shedding or chemical resistance is a concern.

What are the critical installation and handling requirements for the Atomfair AF-DC160BF dry cabinet to ensure proper humidity control and prevent damage to stored moisture-sensitive materials?

The cabinet must be transported upright with reinforced outer protection and moved using suitable lifting equipment. After installation, confirm level placement, door sealing, shelf loading, and stable power. Keep the cabinet door closed during normal use and minimize extended ambient exposure of sensitive materials. For ultra-low humidity applications, validate the process and consider nitrogen purge or alarm options.

Atomfair AF-DC160BF 160L anti-static dry cabinet provides low-humidity storage at 10-20% RH using automatic electronic dehumidification and Honeywell sensing. Suitable for moisture-sensitive components but requires proper handling and door discipline.

Positive

  • High-precision Honeywell sensor: Integrated Honeywell temperature and humidity sensor with ±3% RH accuracy and 0.3% annual drift ensures reliable long-term measurement and control.
  • Consumable-free dehumidification: Automatic electronic dehumidification system operates without disposable desiccants, reducing ongoing maintenance and consumable costs.

Trade-offs

  • Fixed low-humidity range: This model is configured for 10-20% RH only; users requiring mid, ultra-low, or extreme-low humidity must select a different model or add a nitrogen purge system.
  • Operating discipline required: Cabinet door must remain closed during normal use and ambient exposure of stored materials minimized to maintain stable low-humidity conditions.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).