Dual-Flow Nitrogen Cabinet 240 L Anti-Static ATOMFAIR®

$1,260.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

240 L dual-flow nitrogen cabinet with anti-static body, 1%-60% RH control, 600 × 400 × 1250 mm size, 3 shelves, and 15-50 L/min recovery. Order now.

SKU: AF-EI-E-DFNC-ESD0-240L
Category:
Brands:

240L Dual-Flow Energy-Saving Nitrogen Cabinet, Anti-Static Cabinet Body

Research-grade laboratory product

Product Overview

The 240 L configuration uses a anti-static cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 600 × 400 × 1250 mm, inner dimensions of 555 × 370 × 1080 mm and 3 adjustable shelves.

This dual-flow energy-saving nitrogen cabinet is designed for low-humidity storage tasks where fast recovery after door opening and reduced unnecessary gas consumption are both important. It supports moisture-sensitive materials that require controlled nitrogen-assisted drying while improving atmosphere recovery and lowering routine nitrogen demand.

Typical application areas include research laboratories, electronics workshops, component staging rooms, optical storage spaces and inspection environments where cabinet doors may be opened more frequently during routine work. This body type is suitable for electrostatic-control areas and ESD-sensitive material handling.

The cabinet combines 1.2 mm galvanized steel cabinet with anti-static exterior coating, tempered-glass viewing doors and magnetic sealing, dual-flow nitrogen management, automatic switching between large-flow and small-flow operation, tempered-glass viewing areas and perforated adjustable shelves for stable day-to-day cabinet performance.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-DFNC240F
Product Family Dual-Flow Energy-Saving Nitrogen Cabinet
Cabinet Body Anti-static cabinet body
Nominal Capacity 240 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 600 × 400 × 1250 mm
Inner Dimensions (W × D × H) 555 × 370 × 1080 mm
Adjustable Shelf Quantity 3
Cabinet Material 1.2 mm galvanized steel cabinet with anti-static exterior coating and 5 mm tempered-glass viewing doors
Control Mode Automatic software-controlled nitrogen management
Large-Flow Meter Setting 15-50 L/min
Small-Flow Meter Setting 1-5 L/min
Switching Logic Automatic switching between large-flow and small-flow operation
Operating Characteristic Fast recovery after door opening with reduced unnecessary nitrogen use
Suitable Stored Materials Moisture-sensitive electronic parts, optical components and frequently accessed laboratory materials

Key Features and Advantages

  • Dual-flow nitrogen control with large-flow settings of 15-50 L/min and small-flow settings of 1-5 L/min.
  • Automatic switching between high-flow and low-flow operation without manual intervention.
  • Fast recovery after door opening helps restore the cabinet atmosphere while reducing unnecessary nitrogen consumption.
  • Sealed galvanized steel cabinet structure with tempered-glass viewing areas for controlled dry storage.
  • Perforated adjustable shelves support airflow circulation and flexible material arrangement.

Optional Items and Consultation

  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Electronic dehumidification module that can operate together with the gas-filling unit to reduce nitrogen use.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, component staging rooms, optical storage spaces and inspection environments that require low-humidity nitrogen-assisted storage with rapid recovery after cabinet access.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 3 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This cabinet requires a stable indoor surface and a continuous nitrogen gas supply with flow settings between 1 and 50 L/min. The stored materials must be moisture-sensitive and compatible with a low-humidity nitrogen atmosphere to prevent damage.

  • Gas supply constraint: The cabinet's automatic switching between large-flow and small-flow operation depends on a stable nitrogen supply at specified flow rates.
  • Installation constraint: Level installation on a stable surface is required to maintain proper door sealing and humidity control.
  • Material compatibility: Only electrostatic-discharge-sensitive components and moisture-sensitive materials suitable for dry nitrogen storage should be placed inside.
  • Environmental limit: The humidity must be maintained within 1%-60% RH to protect stored items and avoid accelerated degradation.
  • Operational constraint: The cabinet door must remain closed during normal use to sustain low humidity and reduce unnecessary nitrogen consumption.

These steps guide the initial setup and daily operation of the cabinet to ensure safe and efficient nitrogen-assisted storage. Proper installation and parameter selection are critical for maintaining low humidity and rapid recovery after door openings.

Required Equipment: Nitrogen gas supply line, Electrical power cord, Spirit level

  1. Inspect after delivery
    Inspect the cabinet for any transit damage and verify that all seals, doors, and shelves are intact.
  2. Install on stable surface
    Place the cabinet on a level, stable indoor surface and adjust the feet to eliminate any rocking.
  3. Connect utilities
    Connect the nitrogen gas supply to the cabinet's inlet and plug the power cord into a grounded outlet.
  4. Verify level and sealing
    Confirm the cabinet is perfectly level using a spirit level and check that the magnetic door seal is continuous and unobstructed.
  5. Set flow parameters
    Adjust the large-flow meter to 15-50 L/min and the small-flow meter to 1-5 L/min according to stored material requirements.
  6. Load materials evenly
    Distribute moisture-sensitive items across the three perforated shelves without blocking airflow or exceeding rated shelf weight.
  7. Close and stabilize
    Close the tempered-glass door and allow the cabinet to reach the target humidity set point before introducing sensitive samples.

What is the performance trade-off between the large-flow and small-flow settings on the 240L Dual-Flow Nitrogen Cabinet?

The large-flow setting (15-50 L/min) is used for rapid atmosphere recovery after door openings, while the small-flow setting (1-5 L/min) maintains low humidity with reduced nitrogen consumption during normal closed-door operation. The cabinet automatically switches between these modes to balance fast recovery with minimized gas usage, making it suitable for frequently accessed storage.

Can the anti-static cabinet body and dual-flow system accommodate ESD-sensitive optical components and frequently accessed electronics?

Yes, the cabinet is explicitly designed for electrostatic-control areas and ESD-sensitive material handling, featuring a 1.2 mm galvanized steel body with anti-static exterior coating. It is suitable for moisture-sensitive electronic parts, optical components, and frequently accessed laboratory materials, with perforated shelves that support airflow and flexible arrangement.

What infrastructure and installation requirements are needed for the 240L Anti-Static Nitrogen Cabinet?

The cabinet requires a stable indoor surface, a reliable nitrogen gas supply (large-flow 15-50 L/min, small-flow 1-5 L/min), and a power connection if optional accessories like LED lighting or electronic dehumidification modules are used. Before operation, verify stable gas-supply conditions, level installation, door sealing, and even distribution of stored items across the three adjustable shelves.

The AF-DFNC240F 240L dual-flow nitrogen cabinet provides efficient humidity control with automatic large/small-flow switching for rapid recovery after door openings while conserving nitrogen, and its anti-static construction supports ESD-sensitive applications. Operational dependencies include a continuous nitrogen source and stable indoor placement.

Positive

  • Dual-flow nitrogen management: Automatic switching between large-flow (15-50 L/min) and small-flow (1-5 L/min) operation enables fast atmosphere recovery after door opening while minimizing unnecessary nitrogen consumption during steady-state holding.
  • Anti-static cabinet construction: The 1.2 mm galvanized steel cabinet with anti-static exterior coating provides electrostatic discharge protection for sensitive electronic components and moisture-sensitive materials.

Trade-offs

  • Requires external nitrogen supply: The cabinet relies on a continuous nitrogen source for humidity control; stable gas-supply conditions must be verified before operation, and an optional nitrogen generator or external line is necessary.
  • Indoor installation only: The cabinet must be installed on a stable indoor surface with controlled ambient conditions; it is not designed for outdoor or uncontrolled environments.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).