Constant Temperature Incubator 210 L, AF-HN210S ATOMFAIR®

$780.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

210 L constant temperature incubator with RT+5 to 100 °C control, 0.1 °C resolution, 800 W input, natural convection and PID timing. Order now.

SKU: AF-LE-E-HNCI-0210-60S1
Category:
Brands:

Precision Constant Temperature Incubator, 210 L
Research-grade laboratory product
Product Overview

Precision Constant Temperature Incubator, 210 L is a practical chamber for bacterial culture, fermentation, constant-temperature experiments and laboratory incubation tasks. It brings together 210 l of usable space, RT+5 to 100 C, so the chamber can keep samples in a steady, repeatable working condition.

The series features a cleanable chamber layout, adjustable shelf spacing, a top exhaust valve for moisture removal and a silicone sealing ring that helps with insulation and noise reduction. The cabinet uses a vertical frame cabinet with high-quality cold-rolled plate forming, a powder-coated exterior, a silicone sealing ring and a top exhaust vent, with an internal working room of 500 x 600 x 700 mm and an external footprint of 635 x 751 x 962 mm. That combination of chamber size, shell build and liner material makes the unit easier to place, clean and use in routine laboratory work.

The series uses natural convection and precise temperature control to keep the chamber stable for routine culture and thermal test work. The stated input power is 800 W, and the timer range is 0 to 9999 min. It is well suited to the day-to-day work listed above, including culture, incubation, climate simulation or illuminated growth tasks, depending on the family.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-HN210S
Capacity 210 L
Temperature Control Range RT+5 to 100 C
Temperature Resolution 0.1 C
Temperature Fluctuation +/- 0.5 C
Controller Smart digital PID controller with timing, over-temperature alarm, deviation correction and self-tuning
Chamber Material Galvanized cold-rolled steel inner liner
Exterior Shell Cold-rolled steel shell with electrostatic powder coating
Power / Input 800 W
Power Supply AC220V 50Hz
Timer Range 0 to 9999 min
Internal Dimensions 500 x 600 x 700 mm
External Dimensions 635 x 751 x 962 mm
Net Weight 59 Kg
Shelves / Trays 2 shelves
Operating Mode Natural convection
Configuration Note S version uses a galvanized iron liner
Optional Accessories and Functions RS485/232 interface and communication software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; CO2 controller; light-intensity detection and control system
Performance Features
  • PID temperature control supports accurate setpoint management during routine incubation. This supports more stable setpoint tracking and quicker recovery after door openings.
  • Timing, over-temperature alarm, deviation correction and self-tuning improve operating safety and ease of use. This helps protect samples and alerts operators when abnormal conditions occur.
  • Natural convection provides stable temperature distribution for standard incubation tasks. This supports more reliable day-to-day chamber use.
  • Silicone sealing and a top exhaust vent help maintain insulation while releasing moisture. This supports more reliable day-to-day chamber use.
  • Powder-coated cold-rolled steel construction improves cabinet durability and appearance. This supports more reliable day-to-day chamber use.
  • The S and BS liner options support different cleaning and corrosion-resistance preferences. This supports more reliable day-to-day chamber use.
APPLICATION SCOPE: Suitable for bacterial culture, fermentation, constant-temperature experiments and laboratory incubation tasks in universities, laboratories, research institutes and quality-control environments that need controlled chamber performance.
HANDLING: Check the liner type, shelving and installation space before placing the unit. Keep the exhaust vent clear and avoid blocking the cabinet airflow path. Every unit is shipped with reinforced packaging for transport safety; keep the unit upright during unloading and positioning.
IMPORTANT NOTICE: The controller supports timing, over-temperature alarm, temperature-deviation correction and self-tuning functions. The optional accessories listed on this page are communication, printing, USB storage, alarm and gas-intake add-ons. Any quoted amount refers to the chamber body only and does not include freight. Freight should be confirmed separately according to the delivery destination.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The unit requires a stable AC220V 50Hz power supply and must be positioned with unobstructed airflow around the cabinet. The chamber is designed for controlled temperature operation between RT+5 and 100°C, with a silicone seal and top exhaust vent that must remain clear to maintain insulation and moisture release.

  • Power and Electrical Safety: Connect the incubator only to a properly grounded AC220V 50Hz power source matching the 800W input rating to prevent electrical hazards.
  • Ventilation and Airflow: Keep the top exhaust valve and cabinet airflow paths unobstructed to ensure proper moisture removal and temperature uniformity.
  • Handling and Positioning: Keep the unit upright during unloading and positioning, and verify the installation space accommodates the external dimensions of 635 x 751 x 962 mm.
  • Over-Temperature Protection: Ensure the over-temperature alarm is functional before use to protect samples from thermal runaway conditions.

This procedure covers the safe setup and operation of the incubator for routine culture and incubation tasks. Follow these steps to achieve stable temperature control and avoid operational errors.

Required Equipment: Precision Constant Temperature Incubator 210 L, Digital PID controller with timing and alarm functions

  1. Position the unit
    Place the incubator on a level, stable surface with adequate clearance around the cabinet for airflow and ventilation.
  2. Connect to power
    Plug the unit into a properly grounded AC220V 50Hz power outlet that matches the 800W input rating.
  3. Set the temperature
    Use the PID controller to set the desired temperature within the range of RT+5 to 100°C, adjusting the setpoint as needed.
  4. Configure the timer
    Set the timer to the required duration between 0 and 9999 minutes for timed incubation cycles.
  5. Load the samples
    Place samples on the adjustable shelves, ensuring they do not block the internal airflow or the top exhaust vent.
  6. Monitor the operation
    Verify the temperature fluctuation remains within ±0.5°C and that the over-temperature alarm is active during the run.
  7. Complete the cycle
    After the timer ends, remove the samples and turn off the unit, allowing the chamber to cool before cleaning.

What is the minimum operating temperature of the AF-HN210S constant temperature incubator?

The minimum temperature is RT+5°C (room temperature plus 5°C). For a typical laboratory ambient of 25°C, the lowest setpoint is approximately 30°C. The temperature control range is RT+5 to 100°C with a resolution of 0.1°C and fluctuation of ±0.5°C.

Can the AF-HN210S incubator be integrated with external data logging or CO2 control?

Yes, the incubator supports optional RS485/232 interface and communication software for data logging, as well as an optional CO2 inlet and CO2 controller for gas control. Other optional accessories include an embedded printer, USB data storage, wireless alarm system, and light-intensity detection and control system.

What are the installation and ventilation requirements for the AF-HN210S incubator?

The unit uses natural convection and has a top exhaust vent for moisture release. Keep the exhaust vent clear and avoid blocking the cabinet airflow path. The external dimensions are 635 x 751 x 962 mm, and the unit weighs 59 kg. It requires an AC220V 50Hz power supply with 800W input. Ensure adequate space for ventilation and upright positioning during transport.

The Atomfair AF-HN210S Precision Constant Temperature Incubator (210 L) uses natural convection and a PID controller with self-tuning to maintain ±0.5 °C fluctuation from RT+5 to 100 °C, suitable for bacterial culture and fermentation. The galvanized cold-rolled steel liner and powder-coated exterior offer corrosion resistance and cleanability, but the 800 W input and AC220V 50Hz power requirement demand specific lab infrastructure.

Positive

  • PID control with self-tuning: Smart digital PID controller with timing, over-temperature alarm, deviation correction, and self-tuning ensures stable setpoint management and rapid recovery after door openings, improving operational safety and sample protection.
  • Natural convection stability: Natural convection provides uniform temperature distribution for standard incubation tasks, supporting reliable day-to-day chamber use without forced airflow that could disturb sensitive cultures.

Trade-offs

  • AC220V 50Hz power requirement: The incubator requires a dedicated AC220V 50Hz power supply (800 W input), which may necessitate electrical infrastructure upgrades in labs with 110V or 60Hz mains, limiting plug-and-play deployment.
  • Natural convection temperature gradient: Natural convection, while gentle, can produce vertical temperature gradients in the 210 L chamber, requiring careful shelf placement and periodic validation to ensure uniform conditions across all samples.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).