100L Four-Chamber Biochemical Incubator 0-60°C ATOMFAIR®

$6,700.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 100 L four-chamber biochemical incubator with 0-60°C range, 0.1°C resolution, ±1°C uniformity, and 4400 W input. Order now.

100L Multi-Chamber Four-Chamber Biochemical Incubator, 0-60°C
Research-grade laboratory product
Product Overview

100L Multi-Chamber Four-Chamber Biochemical Incubator, 0-60°C

The cabinet layout is defined by the chamber size is 500x450x450mm, overall dimensions are 1300x805x1885mm, the standard shelf setup is 2 shelves per chamber, input power is 4400 W, the power supply is AC220V 50Hz. These dimensions and electrical requirements help laboratories plan bench-side placement, floor-standing installation, teaching use, quality inspection, research sample staging, and repeated daily workflows.

Temperature performance includes 0.1°C temperature resolution, high temp ±0.5°C; low temp ±0.5°C fluctuation control, ±1°C at 25°C temperature uniformity, a timer range of 0 to 5999 min. The working chamber uses Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading. This construction supports regular loading, cleaning, observation, and repeated operation where stable environmental conditions are important.

Control options are shown as AF-BI100-4BOX: Liquid-crystal display controller. Optional functions may include an embedded printer, RS485 communication, USB data transfer, independent over-temperature alarm protection, multi-segment programmable control, and UV sterilization for applicable mold configurations. Accessory availability and custom chamber-size requirements can be checked by e-mail before ordering.

Product Specifications
Parameter Specification
Product Type Four-Chamber Biochemical Incubator
Nominal Capacity 100 L
Atomfair Models AF-BI100-4BOX
Temperature Range 0-60°C>
Temperature Resolution 0.1°C
Temperature Fluctuation high temp ±0.5°C; low temp ±0.5°C
Temperature Uniformity ±1°C at 25°C
Input Power 4400 W
Power Supply AC220V 50Hz
Ambient Temperature +5 to 30°C
Chamber Size 500x450x450mm
Overall Dimensions 1300x805x1885mm
Shelves 2 shelves per chamber
Timer 0 to 5999 min
UV Sterilization Optional
Inner Chamber and Insulation Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading.
Controller Configuration AF-BI100-4BOX: Liquid-crystal display controller
Optional Accessories Optional embedded printer or RS485 communication interface for recording temperature changes; USB data transfer for selected configurations; Independent over-temperature alarm system where supported; Multi-segment programmable controller for selected control configurations; UV sterilization status for this configuration: Optional. Some accessories may be non-stock and require lead time; email for availability and quotation.
Key Points and Advantages
  • 0.1°C temperature resolution supports finer setpoint adjustment, which is helpful for routine cultivation, preservation, and method repeatability.
  • The published fluctuation level of high temp ±0.5°C; low temp ±0.5°C helps users maintain steadier chamber conditions during day-to-day experimental cycles.
  • Temperature uniformity of ±1°C at 25°C helps reduce position-related differences inside the chamber, which is valuable when multiple vessels are loaded at once.
  • The multi-chamber structure improves batch separation, making it easier to run parallel work with less door-opening interference between different sample sets.
  • The published shelf configurations help laboratories organize flasks, bottles, trays, and routine test loads more flexibly within the available chamber volume.
  • Optional accessories can include embedded printers, RS485 communication, USB data transfer, independent over-temperature alarm support, multi-segment programmable control, and mold-series UV sterilization where applicable.
  • If a configuration needs a different chamber size or accessory package, the quotation can be adjusted by e-mail before order confirmation.
APPLICATION SCOPE: Suitable for parallel biochemical incubation, comparative batch studies, sample staging, and workflow separation where different materials need similar temperature control without being mixed into one chamber.
PACKAGING: The equipment is prepared with protective inner cushioning, reinforced outer packaging, and transport-oriented structural support to help reduce vibration and handling impact during storage and delivery. Export reinforcement or other packing adjustments can be discussed when project quantity, route, or receiving conditions require it.
IMPORTANT NOTICE: Please confirm the exact configuration, installation footprint, power supply, accessory package, and delivery arrangement before ordering. If a custom chamber size is required, please contact us by e-mail for quotation and availability review.
LABORATORY PROCUREMENT SUPPORT
For model selection, specification comparison, accessory review, or quotation support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Manufacturer: Atomfair LLC

Brand: ATOMFAIR®

The incubator requires an ambient temperature range of +5 to 30°C and a stable AC220V 50Hz power supply with 4400 W input capacity. The mirror stainless-steel inner chamber with rounded-corner transitions supports cleaning but may be susceptible to corrosion if exposed to aggressive chemical vapors without proper ventilation.

  • Temperature Uniformity Constraint: Temperature uniformity of ±1°C at 25°C may degrade if the chamber is overloaded or if door openings are frequent during operation.
  • Power Supply Constraint: The 4400 W input power requires a dedicated circuit with appropriate overcurrent protection to prevent tripping during simultaneous chamber operation.
  • Optional Over-Temperature Alarm Constraint: Independent over-temperature alarm protection, where configured, must be tested periodically to ensure it activates before internal temperature exceeds safe limits for stored samples.

This procedure covers initial placement, power connection, and basic temperature setpoint programming for routine incubation. Verify ambient temperature and electrical specifications before proceeding to avoid operational failures.

Required Equipment: AC220V 50Hz power source with 4400 W capacity, Liquid-crystal display controller (AF-BI100-4BOX)

  1. Position the incubator
    Place the incubator on a level, vibration-free surface with at least 30 cm clearance on all sides for ventilation and access.
  2. Connect to power supply
    Connect the unit to a dedicated AC220V 50Hz outlet rated for 4400 W, ensuring the circuit breaker matches the input power requirement.
  3. Set temperature parameters
    Use the liquid-crystal display controller to set the desired temperature within the 0-60°C range, adjusting in 0.1°C increments for precise control.
  4. Configure timer if needed
    Program the timer from 0 to 5999 minutes using the controller interface to automate incubation cycles or shutdown.
  5. Load samples into chambers
    Place sample vessels on the provided shelves, distributing load evenly across each chamber to maintain temperature uniformity of ±1°C at 25°C.
  6. Verify chamber conditions
    Allow the incubator to stabilize for at least 30 minutes after loading, then confirm temperature readings match setpoints using an external calibrated thermometer.

How does the ±0.5°C temperature fluctuation across both high and low ranges impact the reproducibility of biochemical incubation experiments in this four-chamber incubator?

The incubator maintains temperature fluctuation within ±0.5°C for both high and low temperature ranges, which helps reduce cycle-to-cycle variability during routine cultivation and preservation. This level of control, combined with a 0.1°C resolution and ±1°C uniformity at 25°C, supports method repeatability when running parallel samples across the four independent chambers.

Can this multi-chamber biochemical incubator be connected to a laboratory data acquisition system for remote temperature monitoring?

Yes, the incubator offers optional RS485 communication and USB data transfer interfaces for recording temperature changes. An embedded printer is also available as an accessory. These options allow integration with external data logging or monitoring systems, but availability and lead time should be confirmed by email before ordering.

What are the electrical and environmental installation requirements for the 4400W four-chamber biochemical incubator?

The incubator requires an AC220V 50Hz power supply with a total input power of 4400W. It must be installed in an ambient temperature range of +5 to 30°C. The overall dimensions are 1300x805x1885mm, and each chamber measures 500x450x450mm with two shelves per chamber. These specifications help laboratories plan floor-standing placement and ensure adequate electrical capacity and ventilation.

The 100L four-chamber biochemical incubator (AF-BI100-4BOX) provides independent 0-60°C control per chamber with ±0.5°C fluctuation and ±1°C uniformity at 25°C, enabling parallel batch separation for comparative studies while requiring a 4400 W AC220V 50Hz supply and ambient temperature of +5 to 30°C for stable operation.

Positive

  • Multi-chamber parallel separation: Four independently controlled 100 L chambers allow simultaneous incubation of different sample sets without cross-contamination or door-opening interference, supporting comparative batch studies and workflow separation.
  • Fine temperature resolution and uniformity: 0.1°C resolution and ±1°C uniformity at 25°C minimize position-dependent variability across the chamber, important for reproducible cultivation and preservation with multiple vessels loaded simultaneously.

Trade-offs

  • High continuous power draw: 4400 W input power requires dedicated AC220V 50Hz circuit capacity, which may limit placement flexibility and necessitate electrical infrastructure upgrades in standard lab settings.
  • Elevated ambient temperature constraint: Specified ambient operating range of +5 to 30°C means the unit cannot be placed in unconditioned or warm environments; exceeding 30°C may degrade temperature control stability and uniformity.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).