98L Anti-Oxidation Nitrogen Cabinet, Anti-Static Cabinet BodyResearch-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The cabinet must maintain a controlled low-humidity nitrogen atmosphere (1%–60% RH) to prevent oxidation and moisture absorption of stored materials. Proper operation requires stable gas supply, even load distribution across perforated shelves, and intact door sealing to sustain the inert environment.
- Atmosphere Control: Relative humidity must be maintained within the configured set point (1%–60% RH) using continuous nitrogen flow to avoid material degradation.
- ESD Protection: The anti-static cabinet body and coating prevent electrostatic discharge during handling of sensitive components.
- Load Distribution: Stored items must be distributed evenly across the three adjustable shelves to prevent structural imbalance and maintain internal circulation.
- Sealing Integrity: Magnetic door sealing and tempered-glass doors must remain intact and closed during operation to preserve the nitrogen atmosphere.
This procedure guides initial installation and preparation of the nitrogen cabinet to ensure safe and effective storage of oxidation-sensitive materials. Follow these steps after delivery and before loading materials.
Required Equipment: Nitrogen supply line, Humidity control panel
- Delivery inspection
Inspect cabinet after delivery for any damage and verify that all components are present. - Level installation
Install the cabinet on a stable indoor surface and verify level installation using a level tool. - Utility confirmation
Confirm utility conditions such as power and gas connections before formal use. - Nitrogen flow setup
Connect the nitrogen supply line and adjust the flow rate between 0 and 50 L/min according to storage requirements. - Humidity and alarm configuration
Set the desired humidity control range (1%–60% RH) and configure the over-humidity alarm threshold. - Material loading
Distribute stored materials evenly across the three adjustable shelves to maintain proper circulation. - Door sealing
Close the cabinet door securely to ensure magnetic sealing and maintain the nitrogen atmosphere.
What is the trade-off between using the optional electronic dehumidification module and relying solely on nitrogen flow for humidity control in the 98L anti-oxidation nitrogen cabinet?
The optional electronic dehumidification module reduces nitrogen consumption by operating together with the gas-filling unit, while the base cabinet relies solely on nitrogen flow adjustment (0-50 L/min) for humidity control. The trade-off is that the module adds complexity and cost but lowers nitrogen usage, whereas the standard flow-based method may require higher nitrogen consumption depending on the set humidity level.
Can the 98L anti-oxidation nitrogen cabinet be integrated with an on-site nitrogen generator, and what are the compatibility requirements?
Yes, the cabinet supports an optional nitrogen generator configuration for on-site nitrogen supply. Integration requires stable gas-supply conditions and a controlled nitrogen flow adjustment (0-50 L/min) available on the cabinet. The automatic control system works with the external generator to maintain the desired humidity range of 1%-60% RH.
What utility connections and installation conditions are required for the 98L anti-oxidation nitrogen cabinet?
The cabinet requires a stable power connection for the fully automatic computer control and display, and a stable gas-supply (nitrogen) connection. It must be installed on a stable indoor surface, levelled, with the door properly sealed, and stored items evenly distributed across the 3 adjustable shelves to avoid overloading.
This 98L anti-oxidation nitrogen cabinet features a Honeywell sensor with ±3% RH accuracy, anti-static construction, and adjustable nitrogen flow, but requires a stable external nitrogen supply and is limited to a humidity control range of 1% to 60% RH.
Positive
- Honeywell sensor with high accuracy and low drift: The Honeywell temperature and humidity sensor provides ±3% RH humidity indication accuracy with only 0.3% annual drift, enabling reliable and stable low-humidity monitoring for long-term storage applications.
- Anti-static cabinet body with robust construction: The 1.2 mm galvanized steel cabinet with anti-static exterior coating, 5 mm tempered-glass viewing doors, magnetic sealing, and lockable structure offers durable ESD-safe containment suitable for sensitive material handling.
Trade-offs
- Requires stable external nitrogen supply: Operation depends on a continuous nitrogen source; handling instructions explicitly require verifying stable gas-supply conditions before use, adding infrastructure and consumable cost.
- Humidity control range limited to above 1% RH: The specified control range of 1%–60% RH means the cabinet cannot achieve ultra-low humidity below 1% RH, which may be a limitation for extremely moisture-sensitive materials.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).