160L Anti-Oxidation Nitrogen CabinetResearch-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The cabinet requires a stable nitrogen supply with flow adjustable from 0-50 L/min to maintain a controlled low-humidity atmosphere between 1% and 60% RH. The Honeywell sensor has an annual drift of 0.3% RH, and an over-humidity alarm triggers when measured humidity exceeds the configured setpoint.
- Installation and leveling: Cabinet must be installed on a stable indoor surface and leveled to ensure proper door sealing and reliable operation.
- Item distribution: Stored items should be distributed evenly across the adjustable shelves to maintain uniform nitrogen circulation inside the cabinet.
- Door seal integrity: The magnetic door seal must remain intact and free of damage, as any leakage compromises humidity control.
- Over-humidity alarm: Configure the over-humidity alarm to trigger at a setpoint appropriate for the stored materials to prevent moisture damage.
- Optional upgrades: Optional upgrades such as an electronic dehumidification module can reduce nitrogen consumption while maintaining low humidity.
Initial setup requires stable placement, gas supply verification, and even item distribution across the shelves. Ongoing operation relies on maintaining door sealing and monitoring humidity via the over-humidity alarm.
Required Equipment: Nitrogen gas supply regulator (0-50 L/min)
- Site preparation and installation
Install the cabinet on a stable indoor surface and verify level installation using a spirit level. - Gas supply verification
Verify stable nitrogen gas supply conditions before operation by checking the flow regulator and pressure. - Item loading
Distribute stored items evenly across the three adjustable shelves to maintain uniform nitrogen circulation. - Door sealing check
Close the door and confirm the magnetic seal engages fully to maintain the controlled atmosphere. - Alarm configuration
Configure the over-humidity alarm setpoint to alert if humidity exceeds the safe storage limit for your materials.
What humidity range can the 160L Anti-Oxidation Nitrogen Cabinet maintain, and how does the optional electronic dehumidification module affect nitrogen consumption?
The standard cabinet controls humidity between 1% and 60% RH. An optional electronic dehumidification module can operate together with the nitrogen unit to reduce nitrogen consumption, though specific consumption reduction figures are not stated in the product documentation.
What gas supply infrastructure is needed to operate the 160L Anti-Oxidation Nitrogen Cabinet, and can it be connected to a central nitrogen line?
The cabinet requires a stable nitrogen supply with flow adjustment from 0 to 50 L/min. It can be connected to a central nitrogen line, but the product documentation does not specify connector type or fitting requirements; users should verify appropriate tubing and connections before operation.
What are the critical handling and installation requirements to ensure the cabinet maintains its sealing and humidity control performance?
Install the cabinet on a stable indoor surface, keep the door closed during normal use, and distribute stored items evenly across the three adjustable shelves. During movement, protect structural and sealing components, and use reinforced wooden-crate packaging for shipment. The magnetic door sealing and tempered-glass doors require careful handling to avoid damage.
The Atomfair AF-AONC160 160L Anti-Oxidation Nitrogen Cabinet delivers precise humidity control (1%-60% RH) using a Honeywell sensor (±3% RH accuracy) and adjustable nitrogen flow (0-50 L/min) in a robust galvanized steel enclosure, but requires an external nitrogen supply and careful installation; the standard model lacks anti-static and corrosion-resistant finishes.
Positive
- High-Accuracy Humidity Sensing: Honeywell temperature and humidity sensor provides ±3% RH indication accuracy with only 0.3% annual drift, ensuring reliable monitoring over time.
- Robust Construction with Viewing Access: 1.2 mm galvanized steel cabinet with 5 mm tempered-glass doors and magnetic sealing offers durability, visibility of stored materials, and secure closure.
Trade-offs
- Requires External Nitrogen Supply: The cabinet relies on a continuous nitrogen flow (0-50 L/min) for atmosphere control; users must have access to a regulated nitrogen source or purchase an optional generator.
- Standard Model Lacks ESD/Corrosion Protection: The standard white cabinet body does not include anti-static coating or stainless steel construction; these are optional upgrades needed for electrostatic-sensitive or corrosive environments.