98L Anti-Static Dry Storage Cabinet 10%-20% RH ATOMFAIR®

$960.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

98L anti-static dry cabinet with 10%-20% RH control, Honeywell ±3% RH sensor, LCD display, 3 shelves and 448 x 400 x 688 mm body. Order now.

SKU: AF-EI-E-DC00-LESD-098L
Category:
Brands:

98L Anti-Static Low-Humidity (10%-20% RH) Dry Cabinets

Dry storage cabinet, low-humidity control

Product Overview

The Atomfair DC-Series AF-DC98BF is a 98L anti-static dry cabinet configured for 10%-20% RH relative humidity control, with an anti-static cabinet body, outer dimensions of 448 x 400 x 688 mm, inner dimensions of 446 x 372 x 598 mm, and 3 adjustable shelves.

This model provides low-humidity storage for moisture-sensitive components that require stronger ambient humidity protection. It is used to prevent moisture absorption, oxidation, micro-structural degradation, optical haze, solderability loss and other humidity-related damage during storage, inspection, production staging or long-term preservation.

Application scenarios include electronics manufacturing lines, SMT component rooms, laboratory sample storage, precision instrument storage, optical workshops, film and powder storage, and industrial quality-control areas requiring lower humidity protection.

The cabinet integrates automatic electronic dehumidification, high-precision Honeywell temperature and humidity sensing, a digital LCD display for humidity, temperature, operating status and fault information, set-point memory after power interruption, tempered-glass viewing doors, reinforced adjustable shelves and sealed cabinet construction for repeatable daily operation.

Specifications

1. Selected Model & Dimension Parameters
Model Cabinet Body Volume Humidity Grade Humidity Range Outer Size Inner Size Shelf Count
AF-DC98BF Anti-static powder-coated steel body 98L Low-Humidity 10%-20% RH 448 x 400 x 688 mm 446 x 372 x 598 mm 3
2. Technical Specifications
Parameter Details
Cabinet Body Anti-static powder-coated steel cabinet body
Humidity Control Range 10%-20% RH
Temperature Display Range 0-99°C
Humidity Display Range 0%-99% RH
Sensor Honeywell temperature and humidity sensor, ±3% RH accuracy and 0.3% annual drift
Display High-definition LCD display for humidity, temperature, operation status and fault codes
Dehumidification System Automatic electronic dehumidification module with no disposable desiccant consumables
Control Mode Microcomputer automatic control with set-point memory after power interruption
Structure 1.2 mm galvanized steel cabinet, 5 mm tempered glass viewing door, magnetic sealing gasket and lockable handle

Key Features and Advantages

  • Selectable humidity grades are split into individual models: A mid-humidity 20%-60% RH, B low-humidity 10%-20% RH, C ultra-low-humidity 1%-10% RH and D extreme-low-humidity 1%-3% RH, allowing the cabinet to match the actual sensitivity of stored materials.
  • High-precision sensing uses a Honeywell temperature and humidity sensor with ±3% RH accuracy and low annual drift for reliable long-term measurement.
  • Efficient automatic dehumidification removes moisture rapidly, requires no disposable desiccant consumables and supports continuous operation with minimal maintenance.
  • Intelligent microcomputer control retains set parameters after power loss and shows real-time humidity, temperature, operating status and fault codes on the LCD display.
  • Robust sealed construction uses a galvanized steel cabinet body, tempered safety glass, double-frame sealing, magnetic gaskets and a lockable handle for stable dry storage.
  • Perforated adjustable shelves support uniform air circulation and make it easier to store components, instruments and samples of different sizes.

Optional Accessories

  • Internal LED Illumination: Moisture-resistant interior lighting improves visibility when checking stored parts, labels and shelf positions.
  • Premium Stainless-Steel Body: High-grade structural body option for cleanrooms, corrosive environments or facilities with stricter hygiene requirements.
  • Nitrogen Purge System: Fast-purge gas valve configuration supports accelerated dehumidification and inert-atmosphere management.
  • RS485 PC Logging Interface: Enables real-time data logging, remote monitoring and traceability of cabinet humidity and temperature status.
  • Over-Humidity Alarm System: Microcomputer alarm function is triggered when the internal humidity exceeds the configured set point.
For tailored configurations or formal technical quotations regarding these options, please contact our engineering team.
APPLICATION SCOPE: Engineered for research laboratories, cleanroom environments, semiconductor assembly lines, SMT component rooms, optical workshops and high-tech industrial quality-control centers managing moisture-sensitive electronic, optical, chemical and archival assets.
HANDLING REQUIREMENT: The cabinet should be transported with reinforced outer protection, kept upright, and moved with suitable lifting or handling equipment according to its volume. After installation, confirm level placement, door sealing, shelf loading and stable power before storing sensitive materials.
IMPORTANT NOTICE: Confirm the exact capacity, humidity grade, cabinet body type and optional accessories before ordering. Keep the cabinet door closed during normal use and minimize extended ambient exposure of sensitive materials. For ultra-low or extreme-low humidity applications, validate the storage process before formal production use and consider nitrogen purge or alarm options when process risk is high.
CONTROLLED DRY STORAGE SOLUTIONS
For volume selection, humidity grade confirmation or optional configuration, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The cabinet must be transported upright with reinforced protection and placed on a level surface. After installation, confirm door sealing, shelf loading, and stable power before storing sensitive materials.

  • Transport Orientation Constraint: The cabinet must be kept upright during transport to prevent damage to internal components.
  • Installation Surface Requirement: Place the cabinet on a level surface to ensure proper door sealing and dehumidification performance.
  • Power Supply Requirement: Connect the cabinet to a stable power supply to maintain consistent humidity control.
  • Door Sealing Check: Confirm the magnetic sealing gasket provides an airtight seal before storing sensitive materials.
  • Operational Door Discipline: Keep the cabinet door closed during normal use to minimize ambient humidity exposure.

Transport the cabinet upright to the installation site and position it on a level surface. After connecting power and confirming sealing, store moisture-sensitive materials while keeping the door closed.

Required Equipment: Suitable lifting or handling equipment

  1. Transport Cabinet Upright
    Transport the cabinet upright with reinforced outer protection using suitable lifting equipment.
  2. Position on Level Surface
    Position the cabinet on a level surface and verify stability.
  3. Confirm Installation Checks
    Confirm level placement, door sealing, shelf loading, and stable power connection.
  4. Store Sensitive Materials
    Store moisture-sensitive materials inside the cabinet after completing installation checks.
  5. Maintain Door Closure
    Keep the cabinet door closed during normal operation.
  6. Validate for Ultra-Low Humidity
    Validate the storage process for ultra-low humidity applications before formal production use.

What performance trade-off should be considered when selecting a low-humidity dry cabinet at 10-20% RH compared to ultra-low or extreme-low humidity models?

The low-humidity 10-20% RH model balances stronger moisture protection for sensitive components without the increased infrastructure demands of ultra-low (1-10% RH) or extreme-low (1-3% RH) cabinets. The source notes that lower humidity grades may require a nitrogen purge system or over-humidity alarm for process risk mitigation, while this model uses automatic electronic dehumidification with no consumables and offers a simpler maintenance profile.

Can the Atomfair 98L anti-static dry cabinet be integrated into an existing laboratory environmental monitoring or data logging system?

Yes, integration is supported via an optional RS485 PC logging interface that enables real-time data logging, remote monitoring, and traceability of cabinet humidity and temperature status. The cabinet also includes an optional over-humidity alarm system triggered when internal humidity exceeds the configured set point, allowing automated alerts in a monitored environment.

What handling and installation precautions are required when setting up the 98L anti-static low-humidity dry cabinet?

The cabinet must be transported upright with reinforced outer protection and moved using suitable lifting equipment for its volume. After installation, confirm level placement, door sealing, shelf loading, and stable power before storing moisture-sensitive materials. The source emphasizes keeping the cabinet door closed during normal use and minimizing extended ambient exposure of stored items.

The ATOMFAIR AF-DC98BF 98L anti-static dry cabinet delivers reliable low-humidity storage (10–20% RH) using a Honeywell sensor with ±3% RH accuracy and automatic electronic dehumidification, but its humidity range is insufficient for ultra-low-humidity applications and the cabinet requires upright transport and reinforced handling.

Positive

  • Honeywell sensor with ±3% RH accuracy: The Honeywell temperature and humidity sensor provides ±3% RH accuracy with 0.3% annual drift, enabling reliable long-term measurement and control without frequent recalibration.
  • Maintenance-free electronic dehumidification: The automatic electronic dehumidification module requires no disposable desiccant consumables, reducing ongoing operational costs and maintenance overhead.

Trade-offs

  • Limited to low-humidity range: The cabinet is configured for 10–20% RH and cannot achieve ultra-low or extreme-low humidity levels (e.g., <1% RH) without model upgrade or nitrogen purge option, restricting its use for highly moisture-sensitive materials.
  • Specific transport and handling requirements: The cabinet must be transported upright with reinforced outer protection and moved with suitable lifting or handling equipment, which adds logistical care compared to standard storage cabinets.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).