1000 L Vertical Cabinet Electric Heated Constant Temperature Incubator
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This incubator requires a stable AC 220 V, 50 Hz power supply and ambient temperature between +5 and +35 °C. The chamber and forced convection system must be accessible for cleaning and unobstructed during operation.
- Power Supply: Connect the incubator to a dedicated AC 220 V, 50 Hz power outlet with proper grounding as specified in the technical specifications.
- Ambient Temperature: Operate the incubator only within an ambient temperature range of +5 to +35 °C to maintain specified temperature control accuracy.
- Access and Ventilation: Keep the chamber, sensors, shelves, filters, doors, and control interfaces accessible for cleaning, inspection, and unobstructed airflow.
- Transport Handling: During transport, keep the packed unit upright and use suitable lifting equipment to prevent damage to the chamber and internal components.
This procedure describes the initial setup and safe handling of the 1000 L vertical cabinet electric heated constant temperature incubator. Follow these steps to install the unit, connect power, and prepare the chamber for incubation work.
Required Equipment: Suitable lifting equipment
- Confirm installation space and power supply
Confirm the installation space accommodates the 1050 × 880 × 2060 mm external dimensions and that a dedicated AC 220 V, 50 Hz power outlet is available. - Transport incubator to location
Keep the packed unit upright during transport and use suitable lifting equipment to move it to the installation location. - Prepare chamber for operation
After unpacking, ensure the chamber, sensors, shelves, filters, doors, and control interfaces are accessible for cleaning and inspection. - Connect power supply
Connect the incubator to the appropriate AC 220 V, 50 Hz power outlet with proper grounding. - Configure optional accessories
Select and connect optional accessories, such as the printer or U-disk data storage, according to the workflow requirements.
Why does the Atomfair AF-EHIN-1000V incubator only go down to RT+5°C and not lower?
The incubator is designed for heating only, without refrigeration, so it cannot cool below ambient. The specified temperature control range is RT+5 to 65°C, meaning it can only maintain temperatures at least 5°C above the room temperature. This is typical for electric heated incubators without a cooling system.
What are the electrical and space requirements for installing the 1000 L Atomfair incubator?
The incubator requires a single-phase AC 220 V, 50 Hz power supply with a rated power of 2200 W. It has external dimensions of 1050 × 880 × 2060 mm (W × D × H), so installation space must accommodate these dimensions plus clearance for ventilation and access. Confirm available space and power prior to installation.
Does the Atomfair 1000 L incubator include over-temperature protection as standard?
No, independent over-temperature protection is not included as standard; it is available as an optional accessory. The standard controller does not include this feature, so labs requiring fail-safe over-temperature monitoring should select the independent over-temperature controller option from the accessory list.
The 1000 L vertical cabinet electric heated incubator uses forced convection and a glass observation door for uniform heating and sample monitoring from RT+5 to 65°C, but demands a 2200 W power supply and substantial installation space.
Positive
- Forced Convection for Uniform Temperature: The forced convection airflow system improves temperature response and chamber uniformity, critical for reproducible incubation results.
- Glass Observation Window: A glass inner door or observation window allows visual monitoring of samples without disturbing the chamber environment.
Trade-offs
- Limited Temperature Range Above Ambient: Temperature control range is RT+5 to 65°C, preventing operation below 5°C above room temperature, which may limit low-temperature incubation applications.
- High Power and Space Requirements: The unit requires a 2200 W, AC 220 V, 50 Hz power supply and has external dimensions of 1050 × 880 × 2060 mm, necessitating significant lab space and handling equipment.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).