Constant Temperature Incubator 35 L 65 °C ATOMFAIR®

$730.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 35 L constant temperature incubator with touchscreen control, RT + 5 to 65 °C range, 200 W power and forced convection. Order now.

SKU: AF-LE-E-CTIN-0035-T035
Category:
Brands:

35 L Constant Temperature Incubator with Touchscreen Control
Research-grade laboratory product
Product Overview

35 L Constant Temperature Incubator with Touchscreen Control is designed for routine constant temperature incubation, sample holding, microbiology work, and general laboratory temperature control. Touchscreen operation, forced convection airflow, and stable constant temperature control for routine incubation workflows. The configuration provides RT + 5 to 65 °C, 200 W rated power, a working chamber of 340 × 320 × 320 mm (W × D × H), and external dimensions of 620 × 440 × 490 mm (W × D × H).

The control and chamber design support practical laboratory operation: 4.3-inch intelligent touchscreen controller. laboratory chamber construction

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include UV sterilization system; embedded printer; U-disk data storage; RS485 interface and communication software; independent over-temperature controller.

This equipment is suited to laboratories that need routine constant temperature incubation, sample holding, microbiology work, and general laboratory temperature control, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-CTIN-035
Product Family Constant Temperature Incubator
Configuration 35 L
Rated Operating Power 200 W
Working Chamber Size 340 × 320 × 320 mm (W × D × H)
Overall Dimensions 620 × 440 × 490 mm (W × D × H)
Temperature Control Range RT + 5 to 65 °C
Temperature Resolution / Fluctuation 0.1 °C / ±0.5 °C
Temperature Uniformity ±1.5 °C at 37 °C
Working Ambient Temperature +5 to +35 °C
Power Supply AC 220 V, 50 Hz
Controller 4.3-inch intelligent touchscreen controller
Standard Shelves 2 shelves
Airflow Forced convection with adjustable circulation fan
Optional Accessories and Functions UV sterilization system; embedded printer; U-disk data storage; RS485 interface and communication software; independent over-temperature controller
Performance Features
  • Forced convection airflow improves temperature response speed and chamber uniformity according to the product design. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • A touchscreen controller supports programmable temperature and time settings with multi-step operation capability. This makes real-time parameter review and routine operation easier in routine constant temperature incubation, sample holding, microbiology work, and general laboratory temperature control.
  • The inner glass door design supports observation while reducing heat loss during checks. This supports controlled, repeatable operation for routine constant temperature incubation, sample holding, microbiology work, and general laboratory temperature control.
  • A stainless-steel inner chamber and electric heating support daily laboratory cleaning and maintenance. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Optional UV sterilization, printer, U-disk export, and RS485 communication are listed for this family. This supports chamber hygiene and contamination-control routines for routine constant temperature incubation, sample holding, microbiology work, and general laboratory temperature control.
  • High-temperature and over-temperature alarms support safer unattended operation. This helps operators identify abnormal conditions during unattended or extended routine constant temperature incubation, sample holding, microbiology work, and general laboratory temperature control.
APPLICATION SCOPE: Suitable for routine constant temperature incubation, sample holding, microbiology work, and general laboratory temperature control in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 620 × 440 × 490 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: UV sterilization system; embedded printer; U-disk data storage; RS485 interface and communication software; independent over-temperature controller. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator must be operated within the specified ambient temperature range of +5 to +35°C and connected to a grounded AC 220V, 50 Hz power supply. Adequate clearance around the unit is required for ventilation and heat dissipation, and the unit must be kept upright during transport to prevent damage.

  • Electrical Safety: Connect the incubator to a grounded power outlet matching the specified voltage and frequency to avoid electrical hazards.
  • Thermal Management: Maintain at least 10 cm clearance on all sides for proper airflow and prevent overheating.
  • Ambient Conditions: Operate only within +5 to +35°C ambient temperature to ensure stable performance and prevent component failure.
  • Transport Orientation: Keep the incubator upright during transport and use appropriate lifting equipment to avoid damage to internal components.
  • Accessibility: Keep all controls, sensors, and ports accessible for routine cleaning and maintenance.

Follow these steps to set up and operate the incubator for routine incubation workflows. Ensure all safety precautions are observed before use.

Required Equipment: Touchscreen controller, Shelves

  1. Inspect the incubator
    Inspect the incubator for any visible damage after unpacking.
  2. Position the incubator
    Place the incubator on a level, non-flammable surface with at least 10 cm clearance on all sides.
  3. Connect power
    Connect the power cord to a grounded AC 220V, 50 Hz outlet.
  4. Set parameters
    Set the desired temperature and time parameters using the touchscreen controller.
  5. Stabilize chamber
    Allow the chamber to stabilize at the set temperature before loading samples.
  6. Load samples
    Load samples onto the shelves, ensuring they do not obstruct airflow.
  7. Monitor operation
    Monitor the display for any alarm indicators and confirm steady operation.

How uniform is the temperature inside the Atomfair AF-CTIN-035 35 L incubator at 37 °C?

At 37 °C, the AF-CTIN-035 maintains a temperature uniformity of ±1.5 °C and a temperature fluctuation of ±0.5 °C, with 0.1 °C resolution. Forced convection with an adjustable circulation fan is used to improve temperature response speed and chamber uniformity. These values apply to the 35 L working chamber of 340 × 320 × 320 mm.

Can the AF-CTIN-035 incubator be used below RT+5 °C or above 65 °C?

No. The AF-CTIN-035 is a constant-temperature incubator with a control range of RT + 5 to 65 °C and a working ambient temperature range of +5 to +35 °C. It is intended for routine incubation, sample holding, microbiology work, and general laboratory temperature control within that band; applications requiring lower-than-ambient or above-65 °C temperatures are outside the stated operating range.

What installation and power infrastructure should be confirmed before operating the AF-CTIN-035?

Before installation, verify available space against the 620 × 440 × 490 mm (W × D × H) external dimensions and confirm an AC 220 V, 50 Hz power supply with 200 W rated power. Keep the chamber, sensors, shelves, filters, doors, test ports, and control interfaces accessible for cleaning, inspection, and operation. During transport, keep the packed unit upright and use suitable lifting equipment to reduce movement and impact risk.

The 35 L constant temperature incubator (AF-CTIN-035) uses forced convection and touchscreen control for routine incubation, with a 35 L working volume, temperature range RT+5 to 65°C, and uniformity ±1.5°C at 37°C, suitable for general microbiology and sample holding workflows.

Positive

  • Forced Convection Airflow: Forced convection design with adjustable circulation fan improves temperature uniformity and response speed, supporting repeatable incubation conditions.
  • Touchscreen Multi-Step Controller: 4.3-inch intelligent touchscreen enables programmable temperature and time settings with multi-step capability, facilitating precise and repeatable protocol execution.

Trade-offs

  • Limited Temperature Range and Uniformity: Temperature range of RT+5 to 65°C and uniformity of ±1.5°C at 37°C may not meet requirements for low-temperature or highly uniform incubation applications.
  • Optional Over-Temperature Protection: Independent over-temperature controller is an optional accessory, not standard; laboratories requiring redundant safety monitoring must order separately.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).