Moistureproof Nitrogen Cabinet 540L Anti-Static ATOMFAIR®

$2,170.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

540 L moistureproof nitrogen cabinet with anti-static body, 1%-60% RH control, 600 × 690 × 1485 mm exterior, and 3 adjustable shelves. Order now.

SKU: AF-EI-E-MNIC-ESD0-540L
Category:
Brands:

540L Moistureproof Nitrogen Integrated Cabinet, Anti-Static Cabinet Body

Research-grade laboratory product

Product Overview

The 540 L configuration uses a anti-static cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 600 × 690 × 1485 mm, inner dimensions of 555 × 640 × 1315 mm and 3 adjustable shelves.

This moistureproof nitrogen integrated cabinet combines electronic dehumidification with nitrogen control in one storage platform for efficient low-humidity recovery. It helps reduce moisture absorption, oxidation, optical haze, solderability loss and storage instability while lowering gas demand compared with ordinary nitrogen-only cabinet operation.

Typical application areas include research laboratories, electronics workshops, optical storage rooms, incoming-material control areas, powder and film storage spaces and quality-control environments that require low-humidity cabinet protection with efficient nitrogen management. This body type is suitable for electrostatic-control areas and ESD-sensitive material handling.

The cabinet combines 1.2 mm galvanized steel cabinet with anti-static exterior coating, tempered-glass viewing doors and magnetic sealing, an electronic dehumidification core with regenerative absorbent polymer, a precision nitrogen-control device, fully automatic switching between system modes and display-based cabinet management for dependable daily operation.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-MNIC540F
Product Family Moistureproof Nitrogen Integrated Cabinet
Cabinet Body Anti-static cabinet body
Nominal Capacity 540 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 600 × 690 × 1485 mm
Inner Dimensions (W × D × H) 555 × 640 × 1315 mm
Adjustable Shelf Quantity 3
Cabinet Material 1.2 mm galvanized steel cabinet with anti-static exterior coating and 5 mm tempered-glass viewing doors
Control Mode Fully automatic switching between dehumidification and nitrogen-control modes
Dehumidification System Electronic dehumidification core with regenerative absorbent polymer
Dehumidification Module Housing ABS plus flame-retardant housing
Nitrogen Control System Precision nitrogen-control device for rapid cabinet humidity reduction
Integrated Efficiency Designed to reduce nitrogen usage by more than 50% compared with ordinary nitrogen cabinets
Suitable Stored Materials Moisture-sensitive electronic parts, optical components, powders, films and laboratory materials

Key Features and Advantages

  • Integrated dual-system architecture combining an electronic dehumidification core with a precision nitrogen-control device.
  • High-performance absorbent polymer and regenerative dehumidification design for repeat-use moisture control.
  • ABS plus flame-retardant housing on the dehumidification module for durable routine cabinet operation.
  • Fully automatic switching logic between dehumidification and nitrogen-control modes according to cabinet humidity conditions.
  • Integrated cabinet design intended to reduce nitrogen usage by more than 50% compared with ordinary nitrogen cabinets.

Optional Items and Consultation

  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, incoming-material control areas, powder and film storage rooms and quality-control environments that require low-humidity cabinet protection with efficient nitrogen management.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 3 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This cabinet requires stable indoor installation with level footing and sealed door closure to maintain humidity control. Proper gas supply, power connection, and even shelf loading are essential to prevent performance degradation or damage.

  • Installation Surface: The cabinet must be placed on a stable, level indoor surface to ensure proper door sealing and structural integrity.
  • Gas Supply: A stable, regulated nitrogen supply must be connected and verified before operation to maintain humidity control.
  • Door Sealing: The magnetic sealing and tempered-glass door must remain closed during normal use to preserve the low-humidity environment.
  • Shelf Loading: Stored items must be distributed evenly across the three adjustable shelves to prevent overloading and maintain structural balance.
  • Environmental Conditions: The cabinet requires power and gas connections within the specified utility conditions; do not exceed the rated application conditions.

This procedure covers the steps for safe installation and initial setup of the cabinet. Follow these steps to ensure proper humidity control and nitrogen efficiency.

  1. Inspect the cabinet
    Inspect the delivered cabinet for any shipping damage and verify that the model and accessories match the order.
  2. Install the cabinet
    Install the cabinet on a stable, level indoor surface with adequate clearance for airflow.
  3. Connect nitrogen supply
    Verify that the nitrogen supply is stable and properly connected to the cabinet's gas inlet.
  4. Confirm utility connections
    Confirm that power and gas connections meet the specified utility conditions before powering on the cabinet.
  5. Load materials
    Distribute stored items evenly across the three adjustable shelves to avoid unbalanced loading.

How does the integrated dehumidification and nitrogen control system reduce nitrogen consumption compared with an ordinary nitrogen-only cabinet?

The integrated system uses an electronic dehumidification core with regenerative absorbent polymer to actively remove moisture, drastically reducing the reliance on continuous nitrogen purging. According to the product description, this design is intended to cut nitrogen usage by more than 50% compared with ordinary nitrogen cabinets, while still achieving rapid humidity recovery and stable low-humidity conditions.

Which ESD-sensitive materials are compatible with the anti-static cabinet body, and what storage constraints apply to powders and films?

The cabinet is designed for moisture-sensitive electronic parts, optical components, powders, films, and laboratory materials in electrostatic-control areas. The anti-static exterior coating on the 1.2 mm galvanized steel cabinet and ESD-safe construction support safe handling of such items. Stored materials must be distributed evenly across the 3 adjustable shelves without exceeding the stated loading conditions, and the cabinet humidity range of 1%–60% RH must be maintained.

What utility connections and installation conditions are required before operating the 540 L nitrogen integrated cabinet?

The cabinet requires a stable nitrogen gas supply and an electrical power connection for automatic mode switching and display-based management. Installation must be on a level, stable indoor surface with the cabinet positioned to maintain magnetic door sealing and tempered-glass door integrity. The product description emphasizes verifying gas-supply conditions and inspecting the unit for level installation and door sealing before formal use, with reinforced wooden-crate packaging recommended for transport.

The 540L anti-static moistureproof nitrogen integrated cabinet combines electronic dehumidification with nitrogen purging for efficient low-humidity storage, reducing nitrogen consumption by over 50% compared to conventional nitrogen-only cabinets, but requires stable gas supply and careful installation to maintain performance.

Positive

  • Integrated dual-system reduces nitrogen usage: Combines electronic dehumidification with precision nitrogen control to achieve low-humidity recovery while reducing nitrogen consumption by more than 50% compared with ordinary nitrogen-only cabinets.
  • Anti-static cabinet body for ESD-sensitive materials: The anti-static exterior coating and galvanized steel construction provide a controlled environment suitable for electrostatic-sensitive components and materials.

Trade-offs

  • Requires stable gas supply and power connection: Operation depends on a stable nitrogen supply and electrical power for the dehumidification and control systems, which must be confirmed before formal use.
  • Handling and installation precautions required: The cabinet must be installed on a stable indoor surface, doors kept closed during use, and structural and sealing components protected during movement to maintain performance and seal integrity.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).