Moistureproof Nitrogen Cabinet 160 L 1%-60% RH ATOMFAIR®

$1,320.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

AF-MNIC160 160 L moistureproof nitrogen cabinet with 1%-60% RH control, 450 × 450 × 1010 mm body, 3 shelves, and more than 50% nitrogen savings. Order now.

SKU: AF-EI-E-MNIC-STD0-160L
Category:
Brands:

160L Moistureproof Nitrogen Integrated Cabinet

Research-grade laboratory product

Product Overview

The 160 L configuration uses a standard white cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 450 × 450 × 1010 mm, inner dimensions of 405 × 420 × 840 mm and 3 adjustable shelves.

This moistureproof nitrogen integrated cabinet combines electronic dehumidification with nitrogen control in one storage platform for efficient low-humidity recovery. It helps reduce moisture absorption, oxidation, optical haze, solderability loss and storage instability while lowering gas demand compared with ordinary nitrogen-only cabinet operation.

Typical application areas include research laboratories, electronics workshops, optical storage rooms, incoming-material control areas, powder and film storage spaces and quality-control environments that require low-humidity cabinet protection with efficient nitrogen management. This body type suits general laboratories, inspection rooms and organized storage areas.

The cabinet combines 1.2 mm galvanized steel cabinet with white exterior panels, tempered-glass viewing doors and magnetic sealing, an electronic dehumidification core with regenerative absorbent polymer, a precision nitrogen-control device, fully automatic switching between system modes and display-based cabinet management for dependable daily operation.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-MNIC160
Product Family Moistureproof Nitrogen Integrated Cabinet
Cabinet Body Standard white cabinet body
Nominal Capacity 160 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 450 × 450 × 1010 mm
Inner Dimensions (W × D × H) 405 × 420 × 840 mm
Adjustable Shelf Quantity 3
Cabinet Material 1.2 mm galvanized steel cabinet with white exterior panels and 5 mm tempered-glass viewing doors
Control Mode Fully automatic switching between dehumidification and nitrogen-control modes
Dehumidification System Electronic dehumidification core with regenerative absorbent polymer
Dehumidification Module Housing ABS plus flame-retardant housing
Nitrogen Control System Precision nitrogen-control device for rapid cabinet humidity reduction
Integrated Efficiency Designed to reduce nitrogen usage by more than 50% compared with ordinary nitrogen cabinets
Suitable Stored Materials Moisture-sensitive electronic parts, optical components, powders, films and laboratory materials

Key Features and Advantages

  • Integrated dual-system architecture combining an electronic dehumidification core with a precision nitrogen-control device.
  • High-performance absorbent polymer and regenerative dehumidification design for repeat-use moisture control.
  • ABS plus flame-retardant housing on the dehumidification module for durable routine cabinet operation.
  • Fully automatic switching logic between dehumidification and nitrogen-control modes according to cabinet humidity conditions.
  • Integrated cabinet design intended to reduce nitrogen usage by more than 50% compared with ordinary nitrogen cabinets.

Optional Items and Consultation

  • Anti-static cabinet body upgrade with ESD-compliant exterior coating for electrostatic-control environments.
  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, incoming-material control areas, powder and film storage rooms and quality-control environments that require low-humidity cabinet protection with efficient nitrogen management.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 3 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The cabinet requires stable indoor installation with level placement and proper door sealing. It must be operated with verified gas supply and power connections, and stored items must be distributed evenly across shelves without exceeding loading limits.

  • Installation Requirements: Install the cabinet on a stable indoor surface and verify level installation and door sealing after delivery.
  • Shelf Loading: Distribute stored items evenly across the 3 adjustable shelf levels and do not exceed the stated shelf-loading conditions.
  • Gas Supply: Verify stable gas-supply conditions before operation and confirm utility connections before formal use.
  • Movement Precautions: Protect structural and sealing components during movement and use reinforced wooden-crate packaging when shipment protection is required.
  • Environmental Conditions: Do not exceed the stated application conditions and keep the door closed during normal use to maintain low-humidity environment.

This procedure covers initial installation, verification, and operation of the cabinet for low-humidity storage. Follow these steps to ensure proper functioning and prevent damage.

  1. Inspect Delivery
    Inspect the cabinet after delivery for any damage.
  2. Place Cabinet
    Place the cabinet on a stable indoor surface and verify level installation.
  3. Check Door Sealing
    Check door sealing to ensure proper closure.
  4. Confirm Utilities
    Confirm power and gas supply connections are stable and functional.
  5. Load Shelves
    Distribute stored items evenly across the 3 adjustable shelves.
  6. Maintain Operation
    Keep the door closed during normal operation to maintain low-humidity conditions.

How does the integrated dual-system architecture of the AF-MNIC160 reduce nitrogen consumption compared to a standard nitrogen-only cabinet?

The integrated design combines an electronic dehumidification core with a precision nitrogen-control device, allowing the dehumidification system to remove most moisture before nitrogen is used for final low-humidity recovery. This reduces nitrogen usage by more than 50% compared with ordinary nitrogen cabinets, as stated in the product specifications.

What types of materials can be stored in the AF-MNIC160, and does it require an external nitrogen supply?

The AF-MNIC160 is designed for moisture-sensitive electronic parts, optical components, powders, films, and laboratory materials. It requires a stable external nitrogen supply unless the optional nitrogen generator is configured, as noted in the optional items section.

What infrastructure and installation conditions are required for the AF-MNIC160 to operate correctly?

The cabinet must be installed on a stable indoor surface, with level placement and proper door sealing verified. It requires power for the electronic dehumidification system and a stable nitrogen gas connection; utility conditions such as power and gas connections must be confirmed before formal use, per the handling instructions.

The Atomfair AF-MNIC160 160L moistureproof nitrogen integrated cabinet combines an electronic dehumidification core with a precision nitrogen control device, achieving humidity control from 1%-60% RH while reducing nitrogen usage by over 50% compared to ordinary nitrogen cabinets, making it suitable for moisture-sensitive materials in laboratory and quality-control environments.

Positive

  • Integrated dual-system reduces nitrogen consumption: The combined electronic dehumidification and nitrogen control architecture is designed to reduce nitrogen usage by more than 50% compared with ordinary nitrogen-only cabinets, lowering operational gas demand.
  • Regenerative polymer dehumidification core: The electronic dehumidification core uses a regenerative absorbent polymer for repeat-use moisture control, eliminating the need for consumable desiccant replacement and supporting long-term low-humidity maintenance.

Trade-offs

  • Requires stable gas and power supply: Formal operation requires stable gas-supply conditions and electrical power connections; unstable utilities may compromise humidity control and nitrogen management performance.
  • Installation and door-sealing sensitivity: The cabinet must be installed on a stable indoor surface and the door must remain closed during normal use; any uneven placement or sealing compromise can degrade humidity control and increase nitrogen consumption.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).