Dual-Flow Nitrogen Cabinet 1435 L Anti-Static, ATOMFAIR®

$2,600.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

1435 L dual-flow nitrogen cabinet with anti-static body, 1%-60% RH control, 1200 × 700 × 1860 mm size, 5 shelves and three doors. Order now.

SKU: AF-EI-E-DFNC-ESD0-14L3
Category:
Brands:

1435L-6 Dual-Flow Energy-Saving Nitrogen Cabinet, Anti-Static Cabinet Body

Research-grade laboratory product

Product Overview

The 1435 L configuration uses a anti-static cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 1200 × 700 × 1860 mm, inner dimensions of 1155 × 650 × 1680 mm and 5 adjustable shelves. The 1435 L layout uses a three-door cabinet.

This dual-flow energy-saving nitrogen cabinet is designed for low-humidity storage tasks where fast recovery after door opening and reduced unnecessary gas consumption are both important. It supports moisture-sensitive materials that require controlled nitrogen-assisted drying while improving atmosphere recovery and lowering routine nitrogen demand.

Typical application areas include research laboratories, electronics workshops, component staging rooms, optical storage spaces and inspection environments where cabinet doors may be opened more frequently during routine work. This body type is suitable for electrostatic-control areas and ESD-sensitive material handling.

The cabinet combines 1.2 mm galvanized steel cabinet with anti-static exterior coating, tempered-glass viewing doors and magnetic sealing, dual-flow nitrogen management, automatic switching between large-flow and small-flow operation, tempered-glass viewing areas and perforated adjustable shelves for stable day-to-day cabinet performance.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-DFNC1435F-6
Product Family Dual-Flow Energy-Saving Nitrogen Cabinet
Cabinet Body Anti-static cabinet body
Nominal Capacity 1435 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 1200 × 700 × 1860 mm
Inner Dimensions (W × D × H) 1155 × 650 × 1680 mm
Adjustable Shelf Quantity 5
Door Configuration Three-door cabinet
Cabinet Material 1.2 mm galvanized steel cabinet with anti-static exterior coating and 5 mm tempered-glass viewing doors
Control Mode Automatic software-controlled nitrogen management
Large-Flow Meter Setting 15-50 L/min
Small-Flow Meter Setting 1-5 L/min
Switching Logic Automatic switching between large-flow and small-flow operation
Operating Characteristic Fast recovery after door opening with reduced unnecessary nitrogen use
Suitable Stored Materials Moisture-sensitive electronic parts, optical components and frequently accessed laboratory materials

Key Features and Advantages

  • Dual-flow nitrogen control with large-flow settings of 15-50 L/min and small-flow settings of 1-5 L/min.
  • Automatic switching between high-flow and low-flow operation without manual intervention.
  • Fast recovery after door opening helps restore the cabinet atmosphere while reducing unnecessary nitrogen consumption.
  • Sealed galvanized steel cabinet structure with tempered-glass viewing areas for controlled dry storage.
  • Perforated adjustable shelves support airflow circulation and flexible material arrangement.

Optional Items and Consultation

  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Electronic dehumidification module that can operate together with the gas-filling unit to reduce nitrogen use.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, component staging rooms, optical storage spaces and inspection environments that require low-humidity nitrogen-assisted storage with rapid recovery after cabinet access.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 5 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This nitrogen cabinet requires a stable gas supply and level installation to maintain the specified humidity control range of 1-60% RH. The cabinet is designed for moisture-sensitive and ESD-sensitive materials, requiring proper sealing and even load distribution to prevent performance degradation or damage.

  • Gas Supply Requirement: The cabinet must be connected to a stable nitrogen supply with flow rates between 1-50 L/min to ensure proper dual-flow operation.
  • Installation Surface: Install the cabinet on a stable, level indoor surface to maintain door sealing and structural integrity.
  • Load Distribution: Distribute stored items evenly across the 5 adjustable shelves to prevent overloading and ensure airflow circulation.
  • Environmental Sensitivity: The cabinet is intended for moisture-sensitive and ESD-sensitive materials; avoid exceeding the specified humidity range or exposing the cabinet to corrosive environments.
  • Door Sealing: Verify the tempered-glass door seals after installation and during use to maintain the controlled atmosphere.

Position the cabinet on a stable level surface, connect the nitrogen supply, and distribute materials evenly across the shelves. After closing the doors, power on the automatic nitrogen management system and monitor the humidity to confirm the target range is reached.

Required Equipment: Nitrogen gas source with regulator, Leveling instrument

  1. Position and level the cabinet
    Position the cabinet on a stable, level indoor surface and verify that the floor can support the weight using a leveling instrument.
  2. Connect nitrogen supply
    Connect the nitrogen supply to the cabinet's inlet, setting the large-flow meter to 15-50 L/min and the small-flow meter to 1-5 L/min.
  3. Distribute materials on shelves
    Distribute moisture-sensitive items evenly across the 5 adjustable shelves, ensuring no item blocks the airflow perforations.
  4. Seal doors and power on system
    Close the tempered-glass doors and engage the magnetic seals, then power on the automatic nitrogen management system.
  5. Confirm humidity target
    Monitor the humidity display to confirm the cabinet reaches the target humidity within the 1-60% RH range before storing sensitive materials.
  6. Manage door openings
    After each door opening, allow the automatic switching logic to execute large-flow recovery followed by small-flow maintenance to minimize nitrogen consumption.

What is the trade-off between large-flow and small-flow nitrogen settings in the 1435L-6 dual-flow cabinet?

The large-flow setting (15–50 L/min) enables fast atmosphere recovery after door opening, while the small-flow setting (1–5 L/min) reduces unnecessary nitrogen consumption during normal operation. Automatic switching between the two modes balances rapid recovery with economical gas use, as stated in the product specifications.

Can the 1435L-6 nitrogen cabinet be integrated with a nitrogen generator or remote monitoring system?

Yes, the cabinet supports an optional nitrogen generator configuration for on-site nitrogen supply and an optional RS485 communication interface for PC-side monitoring and recorded cabinet-status management. An optional electronic dehumidification module can also operate alongside the gas-filling unit to further reduce nitrogen consumption, as listed in the optional items.

What handling and storage requirements are necessary for installing the 1435L-6 nitrogen cabinet?

Install the cabinet on a stable indoor surface, keep the door closed during normal use, and distribute stored items evenly across the 5 adjustable shelves. For shipment, use reinforced wooden-crate packaging. Verify stable gas-supply conditions before operation and do not exceed stated shelf-loading or application conditions, as noted in the handling and storage instructions.

The Atomfair AF-DFNC1435F-6 is a 1435 L dual-flow energy-saving nitrogen cabinet with anti-static body, automatic gas flow switching between 15-50 L/min and 1-5 L/min, and humidity control from 1% to 60% RH, designed for low-humidity storage of ESD-sensitive materials with rapid atmosphere recovery after door openings.

Positive

  • Dual-flow automatic nitrogen management: Combines large-flow (15-50 L/min) and small-flow (1-5 L/min) operation with automatic switching to rapidly restore low-humidity atmosphere after door openings while minimizing continuous nitrogen consumption during idle periods.
  • Anti-static cabinet construction: 1.2 mm galvanized steel with anti-static exterior coating and tempered-glass viewing doors provides electrostatic discharge protection suitable for ESD-sensitive component storage.

Trade-offs

  • External nitrogen supply dependency: The cabinet relies on an external nitrogen source for operation; users must ensure stable gas supply conditions and may need to budget for ongoing nitrogen consumption or optional on-site nitrogen generator.
  • Installation and handling requirements: Requires stable indoor installation, leveling, and protection of seals during movement; shelf loading must be distributed evenly and not exceed stated limits, and utility conditions (power and gas) must be confirmed before formal use.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).