Anti-Oxidation Nitrogen Cabinet 1435 L ESD ATOMFAIR®

$2,500.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

1435 L anti-static nitrogen cabinet with 1%-60% RH control, 1200 × 700 × 1860 mm body, 5 shelves, Honeywell sensing and 0-50 L/min N2 flow. Order now.

SKU: AF-EI-E-AONC-ESD0-14L3
Category:
Tags:
Brands:

1435L-6 Anti-Oxidation Nitrogen Cabinet, Anti-Static Cabinet Body

Research-grade laboratory product

Product Overview

The 1435 L configuration uses a anti-static cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 1200 × 700 × 1860 mm, inner dimensions of 1155 × 650 × 1680 mm and 5 adjustable shelves. The 1435 L layout uses a three-door cabinet.

This anti-oxidation nitrogen cabinet is designed for oxidation-sensitive and moisture-sensitive materials that benefit from a controlled low-humidity nitrogen atmosphere. It helps reduce moisture absorption, oxidation, optical haze, solderability loss and storage instability during inspection staging, daily handling and long-term preservation.

Typical application areas include research laboratories, electronics workshops, optical part storage rooms, powder and film storage areas, technical archives and quality-control spaces that require organized nitrogen-assisted dry storage. This body type is suitable for electrostatic-control areas and ESD-sensitive material handling.

The cabinet combines 1.2 mm galvanized steel cabinet with anti-static exterior coating, tempered-glass viewing doors and magnetic sealing, Honeywell temperature and humidity sensing, fully automatic computer control, temperature and humidity display, perforated adjustable shelves and 0-50 L/min nitrogen-flow adjustment for repeatable daily operation.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-AONC1435F-6
Product Family Anti-Oxidation Nitrogen Cabinet
Cabinet Body Anti-static cabinet body
Nominal Capacity 1435 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 1200 × 700 × 1860 mm
Inner Dimensions (W × D × H) 1155 × 650 × 1680 mm
Adjustable Shelf Quantity 5
Door Configuration Three-door cabinet
Cabinet Material 1.2 mm galvanized steel cabinet with anti-static exterior coating and 5 mm tempered-glass viewing doors
Control Mode Fully automatic computer control
Display and Monitoring Display-based monitoring for temperature, humidity and operating status
Temperature Display Range -9°C to 99°C
Humidity Display Range 0%-99% RH
Humidity Indication Accuracy ±3% RH
Annual Sensor Drift 0.3%
Sensor Honeywell temperature and humidity sensor
Nitrogen Flow Control 0-50 L/min
Alarm Function Over-humidity alarm support
Suitable Stored Materials Oxidation-sensitive electronic components, optical parts, powders, films and laboratory materials

Key Features and Advantages

  • 1.2 mm galvanized steel cabinet construction with 5 mm tempered-glass viewing panels, magnetic door sealing and a lockable cabinet structure.
  • Honeywell temperature and humidity sensor with ±3% RH humidity indication accuracy and 0.3% annual drift.
  • Fully automatic computer control with temperature display range of -9°C to 99°C and humidity display range of 0%-99% RH.
  • Perforated adjustable shelves support orderly material staging and internal circulation.
  • Nitrogen-control arrangement with 0-50 L/min flow adjustment for controlled cabinet-atmosphere management.

Optional Items and Consultation

  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Electronic dehumidification module that can operate together with the gas-filling unit to reduce nitrogen use.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, optical storage rooms, powder and film storage areas, technical archives and quality-control environments that require controlled nitrogen-assisted dry storage for oxidation-sensitive and moisture-sensitive materials.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 5 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This cabinet requires stable indoor placement, a regulated nitrogen supply, and continuous power for humidity control. Door sealing must be maintained during operation to prevent humidity ingress and maintain inert atmosphere.

  • Installation Surface Requirements: The cabinet must be placed on a level, stable indoor surface to ensure proper door sealing and structural integrity.
  • Nitrogen Supply Requirements: A nitrogen supply with adjustable flow rate between 0 and 50 L/min is required to maintain the controlled low-humidity atmosphere.
  • Door Sealing Integrity: The magnetic door seals must be inspected regularly to prevent ambient moisture from entering the cabinet and degrading the nitrogen atmosphere.
  • Sensor Calibration Drift: The Honeywell temperature and humidity sensor exhibits an annual drift of 0.3% RH, requiring periodic recalibration to maintain indication accuracy.
  • Electrostatic Protection: The anti-static cabinet body must be properly grounded to prevent electrostatic discharge damage to stored ESD-sensitive materials.

This procedure describes the installation and initial configuration of the nitrogen cabinet for oxidation-sensitive storage. Follow these steps to establish a stable inert atmosphere and ensure proper handling of stored materials.

  1. Install Cabinet
    Install the cabinet on a level, stable indoor surface near the nitrogen supply and electrical outlet.
  2. Connect Nitrogen Supply
    Connect the nitrogen supply to the cabinet's gas inlet and adjust the flow control knob to the desired rate between 0 and 50 L/min.
  3. Verify Door Seals
    Verify that the door seals are intact and close the door to initiate the humidity control process.
  4. Distribute Stored Materials
    Distribute stored materials evenly across the adjustable shelves to allow uniform nitrogen circulation and prevent overloading.
  5. Maintain Closed Operation
    Keep the cabinet door closed during normal use and monitor the humidity display to ensure the setpoint is maintained.

How does the optional electronic dehumidification module affect nitrogen consumption in the 1435L-6 anti-oxidation nitrogen cabinet?

The optional electronic dehumidification module operates together with the gas-filling unit to reduce nitrogen usage. This hybrid configuration enables the cabinet to maintain the 1%–60% RH humidity control range with lower continuous nitrogen flow (0–50 L/min adjustable), thereby conserving nitrogen during routine operation. The standard configuration relies solely on nitrogen purge; adding the module is advised for applications prioritizing nitrogen efficiency.

Can the 1435L-6 cabinet with anti-static body be used in ISO-classified cleanroom environments?

The standard cabinet body uses 1.2 mm galvanized steel with an anti-static exterior coating, designed for ESD-sensitive material handling and general laboratory use. It is not explicitly rated for cleanroom particle control. For environments requiring stricter cleanliness, a stainless steel cabinet-body upgrade is available as an optional item. Consult the manufacturer to confirm compatibility with specific cleanroom classifications.

What gas supply and power infrastructure is required for the 1435L-6 anti-oxidation nitrogen cabinet?

The cabinet requires a stable nitrogen supply with flow adjustable from 0 to 50 L/min and standard electrical power for the fully automatic computer control system. Install the unit on a stable indoor surface with leveling per the handling instructions. Verify stable gas-supply conditions and confirm all utility connections (power and gas) before formal operation.

Atomfair 1435L-6 anti-oxidation nitrogen cabinet offers 1435 L capacity with anti-static body, Honeywell humidity sensor, and adjustable nitrogen flow for controlled storage of oxidation-sensitive materials, but requires external nitrogen supply and optional alarm for full monitoring.

Positive

  • Precise humidity control with low drift: Honeywell sensor provides ±3% RH accuracy and 0.3% annual drift, enabling reliable long-term low-humidity storage conditions.
  • Anti-static cabinet construction: 1.2 mm galvanized steel with anti-static coating and tempered-glass doors protect ESD-sensitive components during storage and handling.

Trade-offs

  • Requires external nitrogen supply: The cabinet relies on a stable nitrogen source with 0-50 L/min flow adjustment; users must verify gas-supply conditions before operation.
  • Over-humidity alarm is optional: The over-humidity alarm feature is not standard and must be specified separately, potentially delaying response to humidity excursions.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).