320L Anti-Oxidation Nitrogen Cabinet, Anti-Static Cabinet BodyResearch-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The cabinet requires installation on a stable indoor surface with verified leveling and door sealing. A controlled nitrogen atmosphere with flow adjustment between 0-50 L/min is necessary to maintain humidity within 1%-60% RH for oxidation-sensitive materials.
- Installation Surface: Install the cabinet on a stable indoor surface to prevent tipping and ensure proper door sealing.
- Nitrogen Supply Verification: Verify stable gas-supply conditions before operation to maintain the required low-humidity nitrogen atmosphere.
- Load Distribution: Distribute stored items evenly across the three adjustable shelves to avoid overloading and maintain structural integrity.
- Door Sealing: Keep the door closed during normal use and inspect magnetic sealing after delivery to prevent humidity ingress.
- Utility Connections: Confirm power and gas connections before formal use to ensure reliable operation of the automatic control system.
This procedure describes the initial setup and loading of the 320L anti-oxidation nitrogen cabinet. It ensures the cabinet provides a controlled low-humidity nitrogen atmosphere for oxidation-sensitive materials.
Required Equipment: Nitrogen gas supply, Power connection
- Inspect Delivery
Inspect the cabinet after delivery to check for structural damage and sealing integrity. - Position Cabinet
Place the cabinet on a stable level surface and adjust its feet for proper alignment. - Connect Gas and Power
Connect the nitrogen gas supply to the cabinet's inlet and plug the power cord into a suitable outlet. - Configure Settings
Power on the cabinet and configure the humidity control setpoint within the 1%-60% RH range. - Load Materials
Load oxidation-sensitive materials evenly onto the shelves and close the door securely.
How does the nitrogen flow rate affect the humidity control performance in the 320L anti-static nitrogen cabinet?
The cabinet offers a nitrogen flow adjustment range of 0–50 L/min, but the source does not provide a direct quantitative relationship between flow rate and achievable humidity. The humidity control range is 1%–60% RH, and the system uses fully automatic computer control to maintain the set point. For operations requiring lower nitrogen consumption, an optional electronic dehumidification module can be integrated to reduce gas usage.
Can the 320L anti-oxidation nitrogen cabinet be integrated with a laboratory's existing nitrogen supply or monitoring infrastructure?
Yes, the cabinet is designed for controlled nitrogen-assisted dry storage and requires a stable gas supply. For monitoring integration, an optional RS485 communication interface enables PC-side status logging and remote monitoring. Additionally, an optional nitrogen generator configuration is available for on-site supply, and the Honeywell temperature and humidity sensor provides ±3% RH accuracy with 0.3% annual drift, suitable for laboratory data logging.
What handling and safety precautions are required when operating the 320L anti-static nitrogen cabinet?
The cabinet must be installed on a stable indoor surface, with the door kept closed during normal use. Stored items should be distributed evenly across the three adjustable shelves. The cabinet includes an over-humidity alarm that triggers when humidity exceeds the set value. Before operation, verify stable gas-supply conditions, and during movement, protect the structural and sealing components. The manufacturer recommends reinforced wooden-crate packaging for shipment protection.
320L anti-oxidation nitrogen cabinet with anti-static body, Honeywell sensor (±3% RH accuracy, 0.3% annual drift), adjustable 0-50 L/min nitrogen flow, and 3 perforated shelves; requires external nitrogen supply and careful operational discipline to maintain stable low-humidity conditions.
Positive
- Precision humidity sensing and control: Honeywell sensor with ±3% RH indication accuracy and 0.3% annual drift enables reliable, low-drift humidity monitoring within 1%-60% RH range for oxidation-sensitive materials.
- Adjustable nitrogen flow with perforated shelves: 0-50 L/min flow adjustment combined with perforated adjustable shelves supports controlled atmosphere management and internal circulation for uniform low-humidity environment.
Trade-offs
- External nitrogen supply required: Operation depends on a stable external nitrogen supply and gas-connection infrastructure; no built-in nitrogen generation, requiring utility planning before deployment.
- Operational discipline for stability: Cabinet must remain closed during normal use, items must be evenly distributed across shelves, and any disruption to door sealing or gas supply can compromise humidity control consistency.