Anti-Oxidation N2 Cabinet 240L Anti-Static ATOMFAIR®

$1,120.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

240 L anti-static nitrogen cabinet with 1%-60% RH control, 600 × 400 × 1250 mm body, Honeywell sensor, 0-50 L/min flow and 3 shelves. Order now.

SKU: AF-EI-E-AONC-ESD0-240L
Category:
Tags:
Brands:

240L Anti-Oxidation Nitrogen Cabinet, Anti-Static Cabinet Body

Research-grade laboratory product

Product Overview

The 240 L configuration uses a anti-static cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 600 × 400 × 1250 mm, inner dimensions of 555 × 370 × 1080 mm and 3 adjustable shelves.

This anti-oxidation nitrogen cabinet is designed for oxidation-sensitive and moisture-sensitive materials that benefit from a controlled low-humidity nitrogen atmosphere. It helps reduce moisture absorption, oxidation, optical haze, solderability loss and storage instability during inspection staging, daily handling and long-term preservation.

Typical application areas include research laboratories, electronics workshops, optical part storage rooms, powder and film storage areas, technical archives and quality-control spaces that require organized nitrogen-assisted dry storage. This body type is suitable for electrostatic-control areas and ESD-sensitive material handling.

The cabinet combines 1.2 mm galvanized steel cabinet with anti-static exterior coating, tempered-glass viewing doors and magnetic sealing, Honeywell temperature and humidity sensing, fully automatic computer control, temperature and humidity display, perforated adjustable shelves and 0-50 L/min nitrogen-flow adjustment for repeatable daily operation.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-AONC240F
Product Family Anti-Oxidation Nitrogen Cabinet
Cabinet Body Anti-static cabinet body
Nominal Capacity 240 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 600 × 400 × 1250 mm
Inner Dimensions (W × D × H) 555 × 370 × 1080 mm
Adjustable Shelf Quantity 3
Cabinet Material 1.2 mm galvanized steel cabinet with anti-static exterior coating and 5 mm tempered-glass viewing doors
Control Mode Fully automatic computer control
Display and Monitoring Display-based monitoring for temperature, humidity and operating status
Temperature Display Range -9°C to 99°C
Humidity Display Range 0%-99% RH
Humidity Indication Accuracy ±3% RH
Annual Sensor Drift 0.3%
Sensor Honeywell temperature and humidity sensor
Nitrogen Flow Control 0-50 L/min
Alarm Function Over-humidity alarm support
Suitable Stored Materials Oxidation-sensitive electronic components, optical parts, powders, films and laboratory materials

Key Features and Advantages

  • 1.2 mm galvanized steel cabinet construction with 5 mm tempered-glass viewing panels, magnetic door sealing and a lockable cabinet structure.
  • Honeywell temperature and humidity sensor with ±3% RH humidity indication accuracy and 0.3% annual drift.
  • Fully automatic computer control with temperature display range of -9°C to 99°C and humidity display range of 0%-99% RH.
  • Perforated adjustable shelves support orderly material staging and internal circulation.
  • Nitrogen-control arrangement with 0-50 L/min flow adjustment for controlled cabinet-atmosphere management.

Optional Items and Consultation

  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Electronic dehumidification module that can operate together with the gas-filling unit to reduce nitrogen use.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, optical storage rooms, powder and film storage areas, technical archives and quality-control environments that require controlled nitrogen-assisted dry storage for oxidation-sensitive and moisture-sensitive materials.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 3 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The cabinet requires a stable, regulated nitrogen supply to maintain the 1%-60% RH range. Automatic computer control manages humidity and temperature, but the Honeywell sensor exhibits 0.3% annual drift that may necessitate periodic calibration verification.

  • Nitrogen Supply Stability: The cabinet must be connected to a regulated nitrogen source capable of 0-50 L/min flow; unstable gas supply may cause humidity fluctuations and compromise stored material protection.
  • Environmental Placement: Install on a level, stable indoor surface away from direct sunlight and vibration to ensure door sealing and sensor accuracy.
  • Shelf Loading Distribution: Distribute stored items evenly across the three perforated shelves to maintain uniform gas circulation and prevent overloading beyond structural limits.
  • Humidity Alarm Function: An over-humidity alarm triggers when internal RH exceeds the set point; ensure alarm settings are configured according to material sensitivity.
  • Sensor Drift Consideration: The Honeywell humidity sensor has a stated annual drift of 0.3% RH; periodic recalibration may be required for long-term accuracy in critical storage applications.

This sequence guides installation, gas connection, and initial operation of the cabinet. Follow these steps to establish a stable nitrogen atmosphere for moisture- and oxidation-sensitive materials.

Required Equipment: Regulated nitrogen gas supply (0-50 L/min)

  1. Position and Level Cabinet
    Position the cabinet on a stable indoor surface and verify level installation to ensure proper door sealing and sensor accuracy.
  2. Connect Nitrogen Supply
    Connect a regulated nitrogen gas supply to the cabinet inlet and adjust the flow rate using the built-in flow adjustment control within the 0-50 L/min range.
  3. Set Humidity Target
    Set the desired humidity level using the automatic computer control interface and confirm the setpoint on the digital display.
  4. Load and Monitor
    Distribute oxidation-sensitive materials evenly across the shelves and periodically monitor the temperature and humidity display and alarm status.

How does the adjustable nitrogen flow rate of 0-50 L/min affect the trade-off between humidity control speed and nitrogen gas consumption in the 240L anti-oxidation nitrogen cabinet?

The cabinet allows nitrogen flow adjustment from 0 to 50 L/min, enabling operators to balance the rate of humidity reduction against nitrogen consumption. Higher flow rates achieve faster humidity control but increase gas usage, while lower flow rates are more economical for maintaining a stable low-humidity environment once the set point is reached. An optional electronic dehumidification module can further reduce nitrogen use by operating together with the gas-filling unit.

What types of materials is the 240L anti-oxidation nitrogen cabinet designed to store, and does it support simultaneous storage of ESD-sensitive components and optical parts?

The cabinet is designed for oxidation-sensitive materials including electronic components, optical parts, powders, films, and laboratory materials. The anti-static cabinet body makes it suitable for ESD-sensitive material handling, and the 3 adjustable perforated shelves allow organized storage of different material types simultaneously. The controlled nitrogen atmosphere and humidity range of 1%-60% RH ensure compatibility with a wide range of moisture-sensitive and oxidation-sensitive items.

What are the critical installation and operational requirements for the 240L anti-oxidation nitrogen cabinet to ensure proper performance and safety?

Install the cabinet on a stable indoor surface, ensure level installation, and verify door sealing. Keep the door closed during normal use and distribute stored items evenly across the 3 shelves. Before operation, confirm stable gas-supply conditions and proper power and gas connections. The cabinet features an over-humidity alarm for safety, and users should not exceed the stated shelf-loading or application conditions.

The 240L anti-oxidation nitrogen cabinet with anti-static body provides controlled low-humidity nitrogen atmosphere for ESD-sensitive materials, using Honeywell sensor with ±3% RH accuracy and 0-50 L/min nitrogen flow adjustment, but requires external nitrogen supply and has limited 240L capacity with 3 shelves.

Positive

  • Anti-static cabinet body for ESD safety: The 1.2 mm galvanized steel cabinet with anti-static exterior coating is designed for electrostatic-control areas, making it suitable for handling ESD-sensitive materials and components.
  • High-accuracy Honeywell humidity sensor: The Honeywell temperature and humidity sensor provides ±3% RH indication accuracy with only 0.3% annual drift, enabling reliable long-term humidity monitoring and control.

Trade-offs

  • Requires external nitrogen supply: The cabinet relies on a continuous nitrogen source with 0-50 L/min flow adjustment for atmosphere control, necessitating stable gas-supply infrastructure and periodic refills.
  • Limited capacity with three shelves: The 240 L nominal capacity and three adjustable shelves constrain storage volume and require even load distribution to avoid overloading or airflow obstruction.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).