Anti-Oxidation Nitrogen Cabinet 98L Anti-Static ATOMFAIR®

$950.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

98 L anti-static nitrogen cabinet with 3 shelves, 1%-60% RH control, 0-50 L/min flow, Honeywell sensing, and 448 × 400 × 688 mm body. Order now.

SKU: AF-EI-E-AONC-ESD0-098L
Category:
Tags:
Brands:

98L Anti-Oxidation Nitrogen Cabinet, Anti-Static Cabinet Body

Research-grade laboratory product

Product Overview

The 98 L configuration uses a anti-static cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 448 × 400 × 688 mm, inner dimensions of 446 × 372 × 598 mm and 3 adjustable shelves.

This anti-oxidation nitrogen cabinet is designed for oxidation-sensitive and moisture-sensitive materials that benefit from a controlled low-humidity nitrogen atmosphere. It helps reduce moisture absorption, oxidation, optical haze, solderability loss and storage instability during inspection staging, daily handling and long-term preservation.

Typical application areas include research laboratories, electronics workshops, optical part storage rooms, powder and film storage areas, technical archives and quality-control spaces that require organized nitrogen-assisted dry storage. This body type is suitable for electrostatic-control areas and ESD-sensitive material handling.

The cabinet combines 1.2 mm galvanized steel cabinet with anti-static exterior coating, tempered-glass viewing doors and magnetic sealing, Honeywell temperature and humidity sensing, fully automatic computer control, temperature and humidity display, perforated adjustable shelves and 0-50 L/min nitrogen-flow adjustment for repeatable daily operation.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-AONC98F
Product Family Anti-Oxidation Nitrogen Cabinet
Cabinet Body Anti-static cabinet body
Nominal Capacity 98 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 448 × 400 × 688 mm
Inner Dimensions (W × D × H) 446 × 372 × 598 mm
Adjustable Shelf Quantity 3
Cabinet Material 1.2 mm galvanized steel cabinet with anti-static exterior coating and 5 mm tempered-glass viewing doors
Control Mode Fully automatic computer control
Display and Monitoring Display-based monitoring for temperature, humidity and operating status
Temperature Display Range -9°C to 99°C
Humidity Display Range 0%-99% RH
Humidity Indication Accuracy ±3% RH
Annual Sensor Drift 0.3%
Sensor Honeywell temperature and humidity sensor
Nitrogen Flow Control 0-50 L/min
Alarm Function Over-humidity alarm support
Suitable Stored Materials Oxidation-sensitive electronic components, optical parts, powders, films and laboratory materials

Key Features and Advantages

  • 1.2 mm galvanized steel cabinet construction with 5 mm tempered-glass viewing panels, magnetic door sealing and a lockable cabinet structure.
  • Honeywell temperature and humidity sensor with ±3% RH humidity indication accuracy and 0.3% annual drift.
  • Fully automatic computer control with temperature display range of -9°C to 99°C and humidity display range of 0%-99% RH.
  • Perforated adjustable shelves support orderly material staging and internal circulation.
  • Nitrogen-control arrangement with 0-50 L/min flow adjustment for controlled cabinet-atmosphere management.

Optional Items and Consultation

  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Electronic dehumidification module that can operate together with the gas-filling unit to reduce nitrogen use.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, optical storage rooms, powder and film storage areas, technical archives and quality-control environments that require controlled nitrogen-assisted dry storage for oxidation-sensitive and moisture-sensitive materials.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 3 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The cabinet must maintain a controlled low-humidity nitrogen atmosphere (1%–60% RH) to prevent oxidation and moisture absorption of stored materials. Proper operation requires stable gas supply, even load distribution across perforated shelves, and intact door sealing to sustain the inert environment.

  • Atmosphere Control: Relative humidity must be maintained within the configured set point (1%–60% RH) using continuous nitrogen flow to avoid material degradation.
  • ESD Protection: The anti-static cabinet body and coating prevent electrostatic discharge during handling of sensitive components.
  • Load Distribution: Stored items must be distributed evenly across the three adjustable shelves to prevent structural imbalance and maintain internal circulation.
  • Sealing Integrity: Magnetic door sealing and tempered-glass doors must remain intact and closed during operation to preserve the nitrogen atmosphere.

This procedure guides initial installation and preparation of the nitrogen cabinet to ensure safe and effective storage of oxidation-sensitive materials. Follow these steps after delivery and before loading materials.

Required Equipment: Nitrogen supply line, Humidity control panel

  1. Delivery inspection
    Inspect cabinet after delivery for any damage and verify that all components are present.
  2. Level installation
    Install the cabinet on a stable indoor surface and verify level installation using a level tool.
  3. Utility confirmation
    Confirm utility conditions such as power and gas connections before formal use.
  4. Nitrogen flow setup
    Connect the nitrogen supply line and adjust the flow rate between 0 and 50 L/min according to storage requirements.
  5. Humidity and alarm configuration
    Set the desired humidity control range (1%–60% RH) and configure the over-humidity alarm threshold.
  6. Material loading
    Distribute stored materials evenly across the three adjustable shelves to maintain proper circulation.
  7. Door sealing
    Close the cabinet door securely to ensure magnetic sealing and maintain the nitrogen atmosphere.

What is the trade-off between using the optional electronic dehumidification module and relying solely on nitrogen flow for humidity control in the 98L anti-oxidation nitrogen cabinet?

The optional electronic dehumidification module reduces nitrogen consumption by operating together with the gas-filling unit, while the base cabinet relies solely on nitrogen flow adjustment (0-50 L/min) for humidity control. The trade-off is that the module adds complexity and cost but lowers nitrogen usage, whereas the standard flow-based method may require higher nitrogen consumption depending on the set humidity level.

Can the 98L anti-oxidation nitrogen cabinet be integrated with an on-site nitrogen generator, and what are the compatibility requirements?

Yes, the cabinet supports an optional nitrogen generator configuration for on-site nitrogen supply. Integration requires stable gas-supply conditions and a controlled nitrogen flow adjustment (0-50 L/min) available on the cabinet. The automatic control system works with the external generator to maintain the desired humidity range of 1%-60% RH.

What utility connections and installation conditions are required for the 98L anti-oxidation nitrogen cabinet?

The cabinet requires a stable power connection for the fully automatic computer control and display, and a stable gas-supply (nitrogen) connection. It must be installed on a stable indoor surface, levelled, with the door properly sealed, and stored items evenly distributed across the 3 adjustable shelves to avoid overloading.

This 98L anti-oxidation nitrogen cabinet features a Honeywell sensor with ±3% RH accuracy, anti-static construction, and adjustable nitrogen flow, but requires a stable external nitrogen supply and is limited to a humidity control range of 1% to 60% RH.

Positive

  • Honeywell sensor with high accuracy and low drift: The Honeywell temperature and humidity sensor provides ±3% RH humidity indication accuracy with only 0.3% annual drift, enabling reliable and stable low-humidity monitoring for long-term storage applications.
  • Anti-static cabinet body with robust construction: The 1.2 mm galvanized steel cabinet with anti-static exterior coating, 5 mm tempered-glass viewing doors, magnetic sealing, and lockable structure offers durable ESD-safe containment suitable for sensitive material handling.

Trade-offs

  • Requires stable external nitrogen supply: Operation depends on a continuous nitrogen source; handling instructions explicitly require verifying stable gas-supply conditions before use, adding infrastructure and consumable cost.
  • Humidity control range limited to above 1% RH: The specified control range of 1%–60% RH means the cabinet cannot achieve ultra-low humidity below 1% RH, which may be a limitation for extremely moisture-sensitive materials.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).