Anti-Oxidation Nitrogen Cabinet 240 L 1%-60% RH ATOMFAIR®

$1,120.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

240 L anti-oxidation nitrogen cabinet with 1%-60% RH control, 600 × 400 × 1250 mm body, Honeywell sensor and 0-50 L/min N2 gas flow. Order now.

SKU: AF-EI-E-AONC-STD0-240L
Category:
Brands:

240L Anti-Oxidation Nitrogen Cabinet

Research-grade laboratory product

Product Overview

The 240 L configuration uses a standard white cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 600 × 400 × 1250 mm, inner dimensions of 555 × 370 × 1080 mm and 3 adjustable shelves.

This anti-oxidation nitrogen cabinet is designed for oxidation-sensitive and moisture-sensitive materials that benefit from a controlled low-humidity nitrogen atmosphere. It helps reduce moisture absorption, oxidation, optical haze, solderability loss and storage instability during inspection staging, daily handling and long-term preservation.

Typical application areas include research laboratories, electronics workshops, optical part storage rooms, powder and film storage areas, technical archives and quality-control spaces that require organized nitrogen-assisted dry storage. This body type suits general laboratories, inspection rooms and organized storage areas.

The cabinet combines 1.2 mm galvanized steel cabinet with white exterior panels, tempered-glass viewing doors and magnetic sealing, Honeywell temperature and humidity sensing, fully automatic computer control, temperature and humidity display, perforated adjustable shelves and 0-50 L/min nitrogen-flow adjustment for repeatable daily operation.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-AONC240
Product Family Anti-Oxidation Nitrogen Cabinet
Cabinet Body Standard white cabinet body
Nominal Capacity 240 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 600 × 400 × 1250 mm
Inner Dimensions (W × D × H) 555 × 370 × 1080 mm
Adjustable Shelf Quantity 3
Cabinet Material 1.2 mm galvanized steel cabinet with white exterior panels and 5 mm tempered-glass viewing doors
Control Mode Fully automatic computer control
Display and Monitoring Display-based monitoring for temperature, humidity and operating status
Temperature Display Range -9°C to 99°C
Humidity Display Range 0%-99% RH
Humidity Indication Accuracy ±3% RH
Annual Sensor Drift 0.3%
Sensor Honeywell temperature and humidity sensor
Nitrogen Flow Control 0-50 L/min
Alarm Function Over-humidity alarm support
Suitable Stored Materials Oxidation-sensitive electronic components, optical parts, powders, films and laboratory materials

Key Features and Advantages

  • 1.2 mm galvanized steel cabinet construction with 5 mm tempered-glass viewing panels, magnetic door sealing and a lockable cabinet structure.
  • Honeywell temperature and humidity sensor with ±3% RH humidity indication accuracy and 0.3% annual drift.
  • Fully automatic computer control with temperature display range of -9°C to 99°C and humidity display range of 0%-99% RH.
  • Perforated adjustable shelves support orderly material staging and internal circulation.
  • Nitrogen-control arrangement with 0-50 L/min flow adjustment for controlled cabinet-atmosphere management.

Optional Items and Consultation

  • Anti-static cabinet body upgrade with ESD-compliant exterior coating for electrostatic-control environments.
  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Electronic dehumidification module that can operate together with the gas-filling unit to reduce nitrogen use.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, optical storage rooms, powder and film storage areas, technical archives and quality-control environments that require controlled nitrogen-assisted dry storage for oxidation-sensitive and moisture-sensitive materials.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 3 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The cabinet must be installed on a stable indoor surface with verified level placement and sealed door operation. Utility conditions including power and nitrogen gas connections must be confirmed before formal use, and shelf loading must not exceed stated application conditions.

  • Installation: Install the cabinet on a stable indoor surface and verify level installation and door sealing after delivery.
  • Loading: Distribute stored items evenly across the three adjustable shelves and do not exceed the stated shelf-loading or application conditions.
  • Gas Supply: Verify stable gas-supply conditions before operation, ensuring a reliable nitrogen source is connected to the cabinet.
  • Movement: Protect structural and sealing components during movement and use reinforced wooden-crate packaging when shipment protection is required.
  • Alarm Response: The over-humidity alarm device triggers when measured humidity exceeds the configured set value, indicating out-of-range conditions.

This procedure describes the initial installation and daily operation steps for the nitrogen cabinet. Follow these steps to ensure proper storage conditions for oxidation-sensitive materials.

  1. Inspect and Level
    Inspect the cabinet after delivery and verify level installation and door sealing.
  2. Connect Utilities
    Confirm utility conditions by connecting power and a stable nitrogen gas supply to the cabinet.
  3. Set Nitrogen Flow
    Set the nitrogen flow rate between 0 and 50 L/min to maintain the desired controlled atmosphere.
  4. Load Materials
    Distribute stored items evenly across the three adjustable shelves and close the door securely.
  5. Monitor and Maintain
    Keep the door closed during normal use and monitor the humidity display for any over-humidity alarm triggers.

Should I use the nitrogen-only mode or combine with the optional electronic dehumidification module to reduce nitrogen consumption?

The optional electronic dehumidification module can operate together with the gas-filling unit to reduce nitrogen use. This trade-off involves higher initial cost and complexity versus ongoing savings on nitrogen consumption. For applications with high nitrogen usage or cost sensitivity, the dehumidification module is advantageous, while nitrogen-only operation is simpler and sufficient for intermittent or low-volume storage.

Can the 240L anti-oxidation nitrogen cabinet be integrated with a laboratory PC monitoring system?

Yes, an optional RS485 communication interface enables PC-side monitoring and recorded cabinet-status management. This allows integration with laboratory data logging or environmental monitoring systems. The base model includes only display-based monitoring, so the RS485 interface must be specified at order.

What utility and environmental conditions are required to operate the 240L nitrogen cabinet?

The cabinet requires a stable indoor surface, a reliable power connection, and a gas supply for nitrogen flow (0-50 L/min adjustable). Magnetic door sealing and internal shelf distribution help maintain atmosphere. Verify level installation, door sealing, and gas connections before operation. Do not exceed stated loading or application conditions.

The Atomfair AF-AONC240 240L Anti-Oxidation Nitrogen Cabinet offers controlled low-humidity nitrogen storage for oxidation-sensitive materials, with Honeywell sensor accuracy of ±3% RH and adjustable nitrogen flow up to 50 L/min for precise atmosphere management.

Positive

  • Precise humidity monitoring with low-drift sensor: Equipped with Honeywell temperature and humidity sensor offering ±3% RH indication accuracy and only 0.3% annual drift, ensuring reliable long-term humidity measurement.
  • Adjustable nitrogen flow for atmosphere control: Nitrogen flow adjustable from 0 to 50 L/min allows fine-tuning of cabinet atmosphere to suit different material sensitivities.

Trade-offs

  • Requires external nitrogen supply: Cabinet operation depends on an external nitrogen source; stable gas-supply conditions must be verified before use, adding infrastructure requirements.
  • Humidity range limited to 1% RH minimum: The humidity control range is 1%-60% RH; materials requiring sub-1% RH environments may not be adequately protected without additional dehumidification options.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).