270 L Programmable Controller Water-Jacket Constant Temperature Incubator
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This incubator requires a controlled ambient temperature between +5 and +35°C and a power supply of AC 220 V, 50 Hz. The water jacket level and door closure are monitored to ensure safe operation and prevent alarms.
- Ambient Temperature Constraint: Operate the incubator only within an ambient temperature range of +5 to +35°C.
- Power Supply Constraint: Connect the incubator to a power supply rated AC 220 V, 50 Hz.
- Water Jacket Level Constraint: Maintain the water jacket at the required level to avoid low-water alarm and ensure thermal stability.
- Door Closure Constraint: Close the door promptly after access to prevent extended door-opening alarm and temperature fluctuation.
Follow these steps to safely install the incubator and verify its readiness. Ensure the workspace meets ambient and power requirements before use.
Required Equipment: Lifting equipment
- Confirm Installation Space
Confirm that the installation space accommodates the external dimensions of 750 × 740 × 1050 mm and the ambient temperature is between +5 and +35°C. - Verify Power Supply
Verify that the power supply matches the required AC 220 V, 50 Hz specification. - Transport Incubator
Transport the packed incubator upright and use suitable lifting equipment to avoid damage. - Ensure Accessibility
Keep the chamber, sensors, shelves, filters, doors, test ports, and control interfaces accessible for cleaning, inspection, and operation.
How does the water-jacket heating system in the 270 L incubator maintain temperature stability during power interruptions?
The water-jacket design provides thermal holdover, maintaining chamber temperature even after power loss. The product specifications state that water-jacket heating supports stable chamber temperature and better thermal holdover during power interruption, with temperature uniformity of ±0.5°C at 37°C and fluctuation of ±0.3°C.
What optional communication and data logging interfaces are available for the Atomfair AF-WJIN-270N incubator?
The incubator supports optional RS485 interface with communication software, printer connectivity, and U-disk data storage for data export. These options allow integration with external monitoring systems and data logging for incubation workflows, as listed in the technical specifications.
What alarm conditions does the water-jacket incubator monitor to ensure safe unattended operation?
The incubator includes alarms for high temperature, over-temperature, low water level, and extended door opening. These alarms help operators identify abnormal conditions during unattended or extended incubation runs, supporting laboratory safety and routine monitoring.
The 270 L Programmable Controller Water-Jacket Constant Temperature Incubator provides stable water-jacket thermal holdover and automatic fan speed control for consistent incubation, but its temperature range is limited to RT+5 to 65°C and several add-on functions (UV sterilization, RS485, independent over-temperature controller) are optional rather than standard.
Positive
- Water-jacket thermal stability and holdover: Water-jacket heating supports stable chamber temperature and better thermal holdover during power interruption, ensuring reliable incubation conditions.
- Automatic fan speed control: Automatic fan speed control adjusts airflow when the chamber reaches set temperature, balancing temperature uniformity with sample protection.
Trade-offs
- Limited temperature range above ambient: Temperature control range is RT+5 to 65°C, unsuitable for low-temperature incubation or applications requiring near-ambient stability.
- Optional accessories require separate selection: Key functions such as UV sterilization, printer, RS485 interface, and independent over-temperature controller are optional and must be ordered separately, increasing initial configuration complexity.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).