Product Overview

Top-Light Incubator, 600 L is a practical chamber for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection. It brings together 600 l of usable space, 5 to 60 C and 0 to 10000 lux (6 levels) illumination, so the chamber can keep samples in a steady, repeatable working condition.

The cabinet combines a visible glass inner door, cleanable stainless-steel surfaces and a top-light layout to make sample observation and chamber maintenance easier. The cabinet uses a mirror-finish stainless-steel inner chamber, a tempered-glass inner door, a cold-rolled steel exterior and top lighting, with an internal working room of 680 x 800 x 1100 mm and an external footprint of 920 x 955 x 1795 mm. That combination of chamber size, shell build and liner material makes the unit easier to place, clean and use in routine laboratory work.

The family uses programmable temperature and light control to support plant-growth experiments and routine illuminated incubation. The stated input power is 1200 W, and the timer range is 0 to 9999 min. It is well suited to the day-to-day work listed above, including culture, incubation, climate simulation or illuminated growth tasks, depending on the family.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-GZX600T
Capacity 600 L
Temperature Control Range 5 to 60 C
Temperature Resolution 0.1 C
Temperature Uniformity +/- 1 C
Light Intensity 0 to 10000 Lux (6 levels)
Lighting Faces 2 faces
Controller LCD microcomputer programmable controller
Chamber Material Mirror-finish stainless-steel inner chamber
Exterior Shell Cold-rolled steel shell with electrostatic powder coating
Power / Input 1200 W
Power Supply AC220V 50Hz
Timer Range 0 to 9999 min
Internal Dimensions 680 x 800 x 1100 mm
External Dimensions 920 x 955 x 1795 mm
Net Weight 190 Kg
Shelves / Trays 2 shelves
Configuration Note Top lighting and glass observation door support plant-growth experiments and daily visual inspection
Performance Features
  • Programmable control of temperature and light supports routine illuminated incubation workflows. This supports repeatable plant-growth and photoperiod experiments.
  • Top lighting helps create the illumination conditions needed for plant-growth experiments. This supports repeatable plant-growth and photoperiod experiments.
  • Mirror-finish stainless-steel chamber surfaces and a glass inner door support observation and cleaning. This helps with cleaning, corrosion resistance and long-term laboratory use.
  • Self-diagnosis, over-temperature self-limiting and power-off memory help protect the chamber during routine use. This helps preserve operation settings after power interruptions.
  • The series uses a clean cabinet structure with removable shelving for easier loading and maintenance. This supports more reliable day-to-day chamber use.
  • The same LCD operation framework keeps routine chamber control straightforward. This supports more reliable day-to-day chamber use.
APPLICATION SCOPE: Suitable for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection in universities, laboratories, research institutes and quality-control environments that need controlled chamber performance.
HANDLING: Keep the chamber level, leave enough room for ventilation and confirm the selected shelf and lighting configuration before operation. Every unit is shipped with reinforced packaging for transport safety; keep the unit upright during unloading and positioning.
IMPORTANT NOTICE: When set temperature is 10 C or below, ambient temperature should not exceed 26 C. The page also states a general work environment of 5 to 40 C and relative humidity below 90%. Any quoted amount refers to the chamber body only and does not include freight. Freight should be confirmed separately according to the delivery destination.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The chamber requires a level installation with adequate ventilation and an ambient environment of 5 to 40 °C with relative humidity below 90%. When the set temperature is 10 °C or below, the ambient temperature must not exceed 26 °C to maintain performance.

  • Environmental Limits: Operate the incubator only within the stated ambient temperature and humidity ranges to prevent performance degradation.
  • Installation Requirements: Position the unit on a level surface with sufficient clearance for ventilation and keep it upright during unloading and positioning.
  • Safety Protections: The self-diagnosis, over-temperature self-limiting, and power-off memory features protect the chamber and preserve settings after power interruptions.

This procedure covers the initial setup and routine operation of the incubator for illuminated incubation tasks. Follow these steps to ensure safe and repeatable chamber performance.

Required Equipment: Leveling tool (e.g., spirit level), Programmable LCD controller

  1. Position the chamber
    Place the incubator on a level, stable surface with adequate clearance for ventilation and access.
  2. Verify ambient conditions
    Confirm the room temperature and humidity are within the specified operating range, especially if the set temperature is 10 °C or below.
  3. Configure shelves and lighting
    Install the required shelves and confirm the top-light configuration before loading samples.
  4. Set temperature and light program
    Use the LCD controller to program the desired temperature, light intensity, and timer settings for the experiment.
  5. Load samples
    Place samples inside the chamber, ensuring they do not obstruct airflow or the light source.
  6. Start the incubation cycle
    Initiate the programmed cycle and monitor the chamber through the glass door for proper operation.
  7. Monitor and maintain
    Periodically check the chamber for any error codes or temperature deviations and clean the stainless-steel surfaces as needed.

What is the ambient temperature requirement when operating the incubator at low set points?

When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C. The general work environment is 5 to 40°C with relative humidity below 90%. This constraint ensures stable temperature control and prevents condensation or overheating of the refrigeration system at low set points.

Can the Top-Light Incubator 600 L support photoperiod experiments with programmable light cycles?

Yes, the incubator features an LCD microcomputer programmable controller that simultaneously manages temperature and light intensity. Illumination is provided from 2 faces (top lighting) with 6 selectable levels from 0 to 10000 lux, and a timer range of 0 to 9999 min, allowing precise photoperiod scheduling for plant-growth and tissue-culture experiments.

What power and installation infrastructure is required for the 600 L incubator?

The unit requires a single-phase AC220V 50Hz power supply with a rated input of 1200 W. Its external footprint is 920 x 955 x 1795 mm, and it weighs 190 kg net. The chamber must be placed on a level surface with adequate ventilation clearance. Reinforced packaging is used for transport; the unit must be kept upright during unloading and positioning.

The Top-Light Incubator 600 L provides 600 L of programmable illumination and temperature control for plant growth and microbial culture, with a stainless-steel chamber and glass door for easy observation, but requires careful ambient temperature management at low set points and a dedicated 220V/50Hz power supply.

Positive

  • Programmable temperature and light control: LCD microcomputer controller enables repeatable photoperiod and temperature cycling experiments with 0.1°C resolution and 6-level illumination up to 10000 lux.
  • Stainless-steel chamber with glass door: Mirror-finish stainless-steel interior and tempered-glass inner door facilitate visual inspection and cleaning, improving long-term lab hygiene and corrosion resistance.

Trade-offs

  • Low-temperature ambient constraint: When set temperature is 10°C or below, ambient temperature must not exceed 26°C, limiting placement in warm labs without additional cooling.
  • Heavy and power-specific: Unit weighs 190 kg and requires AC220V 50Hz, necessitating dedicated floor space and compatible electrical infrastructure.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).