Top-Light Incubator, 460 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator requires a level placement with adequate ventilation and ambient temperature not exceeding 26°C when set below 10°C. The chamber must be kept upright during transport and positioning to prevent damage, and the relative humidity should remain below 90%.
- Ambient environment limits: The general work environment must be 5 to 40°C with relative humidity below 90% to ensure reliable operation.
- Low-temperature set point constraint: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C to prevent condensation or performance issues.
- Level and ventilation requirement: The chamber must be placed on a level surface with sufficient clearance around the unit for ventilation and heat dissipation.
- Upright transport and positioning: The unit must be kept upright during unloading and positioning to avoid damage to the refrigeration system or internal components.
Place the incubator on a level surface with at least 10 cm clearance on all sides for ventilation. Confirm the shelf configuration and lighting settings before loading samples, then program the temperature and light cycle as needed.
- Unpack and position chamber
Unpack the incubator and position it upright on a level, stable surface with adequate ventilation clearance. - Connect power supply
Connect the incubator to a grounded AC220V 50Hz power outlet that matches the rated input of 1000 W. - Set temperature and light parameters
Use the LCD microcomputer controller to set the desired temperature, light intensity, and timer duration for the experiment. - Verify ambient conditions
Confirm that the ambient temperature is within the allowed range, especially if the set point is 10°C or below. - Load samples onto shelves
Load samples onto the removable shelves, ensuring they are evenly spaced and do not block airflow. - Start the program and monitor
Start the programmed cycle and periodically observe the samples through the tempered glass inner door without disturbing the chamber environment.
What ambient temperature conditions are required to maintain the incubator at a set temperature of 10°C or below?
For set temperatures of 10°C or below, the ambient temperature must not exceed 26°C. The general work environment is 5 to 40°C with relative humidity below 90%. This ensures proper operation of the cooling system.
How does the programmable controller enable repeatable photoperiod experiments in this 460 L incubator?
The LCD microcomputer programmable controller provides simultaneous control of temperature and light intensity across 6 levels (0 to 10000 lux) with a timer range of 0 to 9999 min, allowing users to program day/night cycles and maintain consistent conditions for plant growth and tissue culture experiments.
What safety features protect the incubator and samples during power interruptions?
The unit includes power-off memory that preserves all operation settings after a power interruption, along with self-diagnosis and over-temperature self-limiting functions to protect the chamber and samples during routine use.
The Top-Light Incubator, 460 L (model AF-GZX460T) provides a 460-liter capacity with top-mounted illumination adjustable in six levels up to 10000 lux, programmable temperature and light control, and a mirror-finish stainless steel interior for easy cleaning and corrosion resistance, making it suitable for plant growth, tissue culture, and microbial incubation; however, operation at set temperatures of 10°C or below requires ambient temperature not exceeding 26°C, and the unit requires a 220V/50Hz power supply.
Positive
- Top lighting with 6-level intensity control: The incubator provides illumination from 0 to 10000 lux in six levels from top-mounted lights, enabling reproducible photoperiod experiments for plant growth, tissue culture, and seed germination.
- Mirror-finish stainless steel interior and glass door: The inner chamber is constructed from mirror-finish stainless steel for corrosion resistance and easy cleaning, while the tempered glass inner door allows visual inspection without disturbing the internal environment.
Trade-offs
- Ambient temperature constraint at low set points: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C, which may limit placement in warm laboratories without additional cooling.
- Specific power supply requirement: The unit requires AC220V 50Hz power input, necessitating a voltage converter or dedicated circuit in regions with different electrical standards, adding to infrastructure planning.