Top-Light Incubator, 250 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator requires a level surface with adequate ventilation and ambient conditions within 5°C to 40°C and below 90% relative humidity. When the set temperature is 10°C or below, ambient temperature must not exceed 26°C to prevent performance degradation.
- Level Surface Requirement: Place the incubator on a level surface to ensure stable operation and prevent mechanical stress.
- Ventilation Clearance: Leave adequate space around the incubator for air circulation and heat dissipation.
- Ambient Temperature Range: Operate the incubator within an ambient temperature range of 5°C to 40°C.
- Humidity Limit: Maintain relative humidity below 90% to avoid condensation and electrical hazards.
- Low Set Temperature Constraint: When the set temperature is 10°C or below, ensure ambient temperature does not exceed 26°C.
Position the incubator on a level surface with adequate ventilation and confirm the shelf and lighting configuration. Program the temperature and light cycles using the LCD controller, then load samples for incubation.
Required Equipment: LCD microcomputer programmable controller
- Position Incubator
Position the incubator on a level surface with adequate ventilation for heat dissipation. - Confirm Configuration
Confirm the selected shelf configuration and lighting levels before operation. - Program Settings
Program the temperature and light cycles using the LCD controller to match the experimental protocol.
How does the 6-level light intensity control affect the temperature uniformity of the Top-Light Incubator, 250 L?
The incubator maintains a temperature uniformity of ±1°C across all six light intensity levels (0 to 10000 lux). However, when the set temperature is 10°C or below, the ambient temperature must not exceed 26°C to ensure accurate performance. This specification is derived from the product's technical data.
What are the electrical and space requirements for installing the Top-Light Incubator, 250 L in a standard laboratory?
The incubator requires an AC220V 50Hz power supply with 800W input power. The unit has external dimensions of 740 x 705 x 1560 mm and weighs 110 kg. It must be placed on a level surface with sufficient clearance for ventilation, and the ambient temperature should be between 5°C and 40°C with relative humidity below 90% for general operation.
What safety features does the Top-Light Incubator, 250 L include to protect samples during operation?
The incubator is equipped with self-diagnosis, over-temperature self-limiting, and power-off memory functions. These features help protect samples by automatically limiting temperature overshoot, detecting faults, and preserving operation settings after power interruptions, ensuring reliable long-term use.
The Top-Light Incubator, 250 L offers programmable temperature and light control with a mirror-finish stainless-steel chamber and glass inner door, suitable for plant growth and microbial culture. However, its top lighting from two faces and ambient temperature constraints at low set points require careful placement and application planning.
Positive
- Programmable temperature and light control: The LCD microcomputer controller supports programmable temperature and light settings, enabling repeatable photoperiod experiments and routine illuminated incubation workflows.
- Mirror-finish stainless-steel chamber and glass door: The mirror-finish stainless-steel inner chamber and tempered-glass inner door facilitate easy observation and cleaning, enhancing corrosion resistance and long-term laboratory use.
Trade-offs
- Ambient temperature constraint at low set points: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C, limiting placement options in warmer laboratory environments.
- Limited top lighting configuration: The top lighting provides only 2 illuminated faces with 6 intensity levels up to 10000 lux, which may be insufficient for applications requiring uniform or higher light distribution across the chamber.