Three-Sided Strong-Light Climate Chamber, 1200 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber must be operated on a level surface with adequate ventilation and within an ambient temperature range of 5 to 40 °C and relative humidity below 90% RH. When the set temperature is 10 °C or below, the ambient temperature must not exceed 26 °C, and performance data are measured under no-load conditions at 20 °C and 50% RH.
- Level placement and ventilation: Position the chamber on a level surface and ensure adequate ventilation space around the cabinet before operation.
- Ambient environment limits: Operate the chamber only when the ambient temperature is between 5 and 40 °C and relative humidity is below 90% RH.
- Low set temperature restriction: When the set temperature is 10 °C or below, the ambient temperature must not exceed 26 °C to maintain stable performance.
- Electrical supply requirement: Connect the chamber to a dedicated AC220V 50 Hz power supply capable of supporting 1800 W input.
- Transport orientation: Keep the unit upright during unloading and positioning to avoid damage from tilt.
Follow these steps to position and prepare the chamber for operation. The steps are derived from the manufacturer's handling instructions and ambient condition requirements.
- Position the chamber
Place the chamber on a level surface with adequate ventilation space around the cabinet. - Confirm ambient conditions
Confirm the room environment meets the ambient temperature and humidity requirements specified in the technical documentation. - Verify power supply
Ensure the power supply matches the rated AC220V 50 Hz and supports the 1800 W input before connecting the chamber.
What ambient temperature is required when operating the Atomfair AF-GZX1200S climate chamber at set temperatures of 10°C or below?
The chamber requires that when set temperature is 10°C or below, ambient temperature should not exceed 26°C. This constraint is stated in the configuration note, and performance data are measured under no-load conditions at ambient temperature 20°C and ambient humidity 50%RH.
Can the Atomfair AF-GZX1200S climate chamber be used for high-humidity plant cultivation at elevated temperatures?
Yes, the chamber includes built-in humidification for high-temperature and high-humidity operation, making it suitable for cultivation and biological workflows requiring moisture control. The illuminated mode range is 10 to 60°C with light intensity up to 18,000 lx from three sides, supporting photoperiod experiments and plant growth.
What are the installation and power requirements for the Atomfair 1200 L strong-light climate chamber?
The chamber requires a 220V AC, 50Hz power supply with 1800W input. The unit weighs 400 kg with external dimensions 1050 x 1400 x 1860 mm; it must be kept level, upright during transport, and with adequate ventilation space. The work environment should stay within 5 to 40°C and below 90%RH.
This 1200 L three-sided strong-light climate chamber provides programmable temperature and illumination control with built-in humidification, suitable for high-light plant growth and microbial culture, but requires careful attention to ambient temperature when operating at low setpoints.
Positive
- Three-sided strong-light illumination: 0 to 18000 lx from three faces supports repeatable high-light plant growth and photoperiod experiments with uniform light distribution.
- Built-in humidification for high-temperature operation: Integrated humidification enables high-temperature and high-humidity conditions, expanding the chamber's utility for cultivation, conditioning, and biological workflows requiring moisture control.
Trade-offs
- Ambient temperature limit at low setpoints: When set temperature is 10°C or below, ambient temperature must not exceed 26°C, imposing a practical constraint on laboratory placement and seasonal operation.
- Performance data under no-load conditions: Specified temperature uniformity (±2°C) and illumination are measured under no-load at 20°C and 50%RH; actual performance may vary with sample loading, ambient conditions, and operational setup.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).