Professional Constant Temperature and Humidity Chamber, 80 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber must be operated within the specified ambient temperature range of 5 to 35°C to maintain stable performance. Electrical safety requires a dedicated AC 220V 50Hz power supply with proper grounding and a 2000W capacity to prevent overload.
- Ambient Temperature Constraint: Operate the chamber only in an environment with ambient temperature between 5°C and 35°C to avoid degradation of control accuracy.
- Power Supply Requirement: Connect the unit to a grounded AC 220V 50Hz power outlet capable of delivering at least 2000W, and avoid sharing the circuit with high-power devices.
- Over-Temperature Protection: The independent over-temperature protection system must be verified periodically to ensure automatic shutdown and operator notification during abnormal conditions.
- Ventilation and Clearance: Maintain sufficient clearance around air inlets, test ports, and drain areas to ensure proper air circulation and prevent overheating.
- Transport and Positioning: Keep the packed chamber upright during transport and use suitable lifting equipment for unloading to prevent structural damage.
Position the chamber on a level surface with adequate clearance and connect to the specified power supply. Set the temperature and humidity parameters using the microcomputer controller and allow the chamber to stabilize before loading samples.
- Position the chamber
Position the chamber on a level surface with adequate clearance around air inlets and rear panel for ventilation. - Connect to power supply
Connect the chamber to a grounded AC 220V 50Hz power supply with a dedicated circuit rated for 2000W to ensure safe operation. - Set temperature and humidity parameters
Set the desired temperature and humidity values using the microcomputer controller, ensuring the set points fall within the chamber's specified ranges of 5-80°C and 40-85%RH. - Allow chamber to stabilize
Allow the chamber to stabilize at the set points before loading samples to ensure uniform conditions. - Use side test port
Use the side test port to insert external probes or sensors for independent verification of chamber conditions during operation. - Test over-temperature protection
Monitor the over-temperature protection system by checking the alarm function during initial setup to confirm it triggers correctly. - Clean the interior
Clean the mirror-finish stainless-steel interior and removable shelves after each use to maintain chamber hygiene.
How does the temperature uniformity vary between high and low temperature set points?
The chamber achieves ±0.5°C fluctuation at high temperature set points and ±1°C at low temperature set points, as specified in the technical specifications. This is due to the balancing control logic and the imported compressor and air-circulation system.
What communication interfaces and data logging options are available for external monitoring?
The chamber supports optional RS232/485 communication interface and software, an embedded printer, and a wireless alarm system. These are selected according to the required configuration. The side test port allows external probe access during operation.
What are the electrical and installation requirements for this chamber?
The chamber requires a 2000 W, AC 220 V, 50 Hz power supply. It operates in a working environment of +5 to 35°C. Installation space must accommodate external dimensions of 550 x 790 x 1080 mm, with accessible air inlets, test ports, shelving, and controller surfaces. The chamber is shipped upright and requires suitable lifting equipment for positioning.
This 80 L constant temperature and humidity chamber delivers stable environmental control via microcomputer balancing logic, but its humidity range of 40-85% RH and specific power requirements limit its application to standard moderate-humidity testing in appropriately equipped laboratories.
Positive
- Balancing Temperature-Humidity Control: The microcomputer balancing control logic maintains stable temperature and humidity conditions, supporting repeatable environmental testing for incubation, cultivation, and stability studies.
- Reliable Compressor and Sensor System: The imported compressor, circulation fan, and humidity sensor provide dependable long-term performance, suitable for continuous laboratory schedules.
Trade-offs
- Limited Humidity Range: The humidity control range of 40% to 85% RH excludes applications requiring very low humidity (below 40% RH) or high humidity (above 85% RH).
- Specific Power and Ambient Requirements: The chamber requires a 2000 W, AC 220 V, 50 Hz power supply and an ambient temperature range of 5 to 35 °C, which may necessitate dedicated electrical infrastructure and climate-controlled lab space.