Temperature Humidity Chamber 800 L -10-100 °C ATOMFAIR®

$21,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Programmable 800 L temperature-humidity chamber, -10 to 100 °C, 35-95%RH, 0.1 °C resolution, touchscreen controller for research testing. Order now.

SKU: AF-LE-E-BPSC-0800-CL80
Category:
Brands:

Programmable Touchscreen Constant Temperature and Humidity Chamber, 800 L,-10-100℃
Research-grade laboratory product
Product Overview

Programmable Touchscreen Constant Temperature and Humidity Chamber, 800 L,-10-100℃ is a programmable touchscreen constant temperature and humidity chamber built for scientific research, biotechnology tests, pharmaceutical packaging, industrial raw-material studies and product lifetime evaluation. This configuration provides 800 l chamber volume, -10 to 100 C, 35%rh to 95%rh humidity control, imported 304 mirror-finish stainless-steel chamber interior and programmable color touchscreen controller with curve display and multi-language interface for stable day-to-day laboratory operation.

This family combines fluorine-free design, imported 304 stainless-steel inner chamber construction, balancing temperature-humidity control, test-port access and color-touchscreen editing as key chamber elements. The chamber combines balancing-control refrigeration system with multi-point safety protection with high-temperature humidity sensor for real-time monitoring, 4 shelves and an interior size of 700 x 860 x 1250 mm, supporting incubation, cultivation, climate simulation or conditioned test work where repeatable environmental control is important.

This range is intended for laboratories that want staged touchscreen programs, multilingual interface, stored curves, PID self-tuning and safety protection in one humidity-chamber platform. Installation planning can be based on the external size of 860 x 1340 x 1995 mm and the stated power requirement of 8050 W. Optional functions such as embedded printer; rs485 communication interface and software; wireless alarm system; communication interface and embedded printer are alternative options that should be selected according to the required configuration allow the unit to be adapted for alarm notification, data output, programmable operation, atmosphere support or other application-specific requirements.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-BCL0800
Manufacturer Model BPS-800CL
Capacity 800 L
Temperature Control Range -10 to 100 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity High temperature: +/- 0.5 C; low temperature: +/- 1 C
Humidity Function 35%RH to 95%RH
Humidity Deviation +/- 3%RH
Controller programmable color touchscreen controller with curve display and multi-language interface
Chamber Material imported 304 mirror-finish stainless-steel chamber interior
Power / Input 8050 W
Power Supply AC 380 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration high-temperature humidity sensor for real-time monitoring
Cooling System balancing-control refrigeration system with multi-point safety protection
Internal Dimensions 700 x 860 x 1250 mm
External Dimensions 860 x 1340 x 1995 mm
Shelves / Light Decks 4 shelves
Program Function Touchscreen controller supports up to 100 programs, 1000 segments and 999 cycle steps, with a maximum time setting of 99 h 59 min per segment
Optional Accessories and Functions embedded printer; RS485 communication interface and software; wireless alarm system; communication interface and embedded printer are alternative options that should be selected according to the required configuration
Performance Features
  • Color touchscreen operation helps simplify program editing, parameter review and real-time curve observation during chamber use. This improves parameter review, setpoint editing and day-to-day operation in controlled chamber workflows.
  • Large program capacity supports staged environmental methods that need repeated cycles and multiple segments. This supports staged test methods and repeatable laboratory workflows that need cycle-based control.
  • PID auto-tuning helps correct temperature and humidity deviations quickly for more stable chamber control. This supports humidity-sensitive incubation, cultivation, conditioning and stability-study applications.
  • Balancing-control refrigeration and imported stainless-steel chamber construction support reliable long-duration operation. This helps support repeated cleaning, chamber hygiene and long-duration laboratory use.
  • Independent alarm and protection functions cover over-temperature, overload, over-current, fan and compressor conditions. This helps maintain dependable low-temperature performance and stable chamber recovery during repeated use.
  • Optional communication, printer and wireless-alarm functions make it easier to store, replay and supervise chamber records. This reduces operational risk by helping protect samples and notifying operators when abnormal conditions occur.
APPLICATION SCOPE: Suitable for scientific research, biotechnology tests, pharmaceutical packaging, industrial raw-material studies and product lifetime evaluation in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 860 x 1340 x 1995 mm, prepare the specified power supply, and keep air inlets, test ports, shelving, drain areas, doors and controller surfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment during unloading and positioning.
IMPORTANT NOTICE: Confirm the exact controller type, lighting form, humidity function, communication option and accessory package before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed according to the delivery location and shipping method.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The chamber must be operated within an ambient temperature range of +5 to 30°C and connected to a dedicated AC 380 V, 50 Hz power supply rated at 8050 W. Installation requires a minimum space of 860 x 1340 x 1995 mm and the chamber must be transported upright using suitable lifting equipment.

  • Environmental Constraint: Operate the chamber only within an ambient temperature range of +5 to 30°C.
  • Electrical Constraint: Connect the chamber to a dedicated AC 380 V, 50 Hz power supply rated at 8050 W.
  • Space Constraint: Allocate installation space of at least 860 x 1340 x 1995 mm for the chamber body.
  • Handling Constraint: Transport the chamber upright and use suitable lifting equipment for unloading and positioning.
  • Maintenance Access Constraint: Keep air inlets, test ports, shelving, drain areas, doors, and controller surfaces accessible for cleaning and maintenance.

This procedure covers the initial installation and positioning of the constant temperature and humidity chamber. Follow these steps to ensure safe setup and proper operation of the unit.

Required Equipment: Lifting equipment

  1. Confirm Installation Space
    Confirm the installation space against the chamber's external dimensions of 860 x 1340 x 1995 mm.
  2. Prepare Power Supply
    Prepare the specified power supply of AC 380 V, 50 Hz with a capacity of 8050 W.
  3. Ensure Accessibility
    Ensure that air inlets, test ports, shelving, drain areas, doors, and controller surfaces remain accessible for cleaning and maintenance.
  4. Transport Upright
    Keep the packed chamber upright during transport to prevent damage.
  5. Use Lifting Equipment
    Use suitable lifting equipment during unloading and positioning to move the chamber safely.

What is the temperature uniformity specification for the Atomfair BPS-800CL chamber at low temperature versus high temperature operation?

The chamber maintains ±0.5°C uniformity at high temperature (above 0°C) and ±1.0°C at low temperature (below 0°C), as stated in the technical specifications. This performance difference should be considered when planning experiments that require tight uniformity at sub-zero setpoints.

What electrical infrastructure is required to install the Atomfair BPS-800CL 800L constant temperature and humidity chamber?

The chamber requires a 380 V, 50 Hz AC power supply with a rated input of 8050 W. The working environment must be between 5 and 30°C. Ensure the installation site has a dedicated circuit meeting these specifications, and that the external dimensions of 860 x 1340 x 1995 mm are accommodated with adequate ventilation and access for maintenance.

What safety protections are integrated into the Atomfair BPS-800CL chamber to prevent sample loss during extended tests?

The chamber includes independent alarm and protection functions covering over-temperature, overload, over-current, fan, and compressor conditions. These safety systems help maintain stable operation and protect samples during long-duration protocols. Optional wireless alarm and RS485 communication provide remote notification of abnormal conditions, reducing operational risk.

The Atomfair BPS-800CL 800 L constant temperature and humidity chamber provides a high-capacity programmable controller with PID auto-tuning and balancing refrigeration, but requires a 380V power supply and has a +/-3%RH humidity deviation that may constrain precision applications.

Positive

  • High-capacity program control: The touchscreen controller supports up to 100 programs, 1000 segments, and 999 cycle steps, enabling staged environmental test methods with complex profiles.
  • PID auto-tuning for stability: PID self-tuning reduces deviation in temperature and humidity, improving control stability for sensitive applications like incubation and conditioning.

Trade-offs

  • Non-standard 380V power requirement: The chamber requires a 380V, 50Hz power supply with 8050W capacity, which may not be available in all laboratory facilities and requires dedicated electrical infrastructure.
  • Humidity accuracy limitation: The specified humidity deviation of +/-3%RH may be insufficient for applications requiring tighter humidity control, such as precise pharmaceutical stability studies.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).