Temperature Humidity Chamber 500L AF-LH20500 ATOMFAIR®

$15,500.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

500 L temperature and humidity chamber with 10-70 °C control, 40-95%RH humidity, 0.1 °C resolution, 3850 W power and 4 shelves for stability testing. Order now.

SKU: AF-LE-E-LHPR-0500-2500
Category:
Brands:

Professional Constant Temperature and Humidity Chamber, 500L,with Printer
Research-grade laboratory product
Product Overview

Professional Constant Temperature and Humidity Chamber, 500L,with Printer is a professional constant temperature and humidity chamber built for industrial research, biotechnology testing, textile testing, material performance evaluation, product packaging studies and shelf-life or stability work. This configuration provides 500 l chamber volume, 10 to 70 C, 40%rh to 95%rh humidity control, mirror-finish stainless-steel chamber interior and microcomputer temperature and humidity controller using balancing control logic for stable day-to-day laboratory operation.

This professional family combines precise temperature-humidity control, fluorine-free refrigeration, imported compressor and circulation fan, mirror-finish stainless-steel interior, removable shelving and a side test port for chamber measurements. The chamber combines imported compressor and air-circulation system with imported humidity sensor, 4 shelves and an interior size of 670 x 720 x 1020 mm, supporting incubation, cultivation, climate simulation or conditioned test work where repeatable environmental control is important.

The I and II configurations provide different temperature and humidity bands, making the range suitable for users who need higher-control humidity testing with optional communication, alarm and program-controller upgrades. Installation planning can be based on the external size of 850 x 1100 x 1930 mm and the stated power requirement of 3850 W. Optional functions such as rs232/485 communication interface and software; lcd program controller; wireless alarm system; embedded printer; communication interface and embedded printer are alternative options that should be selected according to the required configuration allow the unit to be adapted for alarm notification, data output, programmable operation, atmosphere support or other application-specific requirements.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-LH20500
Manufacturer Model LHS-500HC-II
Capacity 500 L
Temperature Control Range 10 to 70 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity High temperature: +/- 0.5 C; low temperature: +/- 1 C
Humidity Function 40%RH to 95%RH
Humidity Deviation +/- 3%RH
Controller microcomputer temperature and humidity controller using balancing control logic
Chamber Material mirror-finish stainless-steel chamber interior
Power / Input 3850 W
Power Supply AC 220 V, 50 Hz
Working Environment +5 to 35 C
Sensor Configuration imported humidity sensor
Cooling System imported compressor and air-circulation system
Internal Dimensions 670 x 720 x 1020 mm
External Dimensions 850 x 1100 x 1930 mm
Shelves / Light Decks 4 shelves
Optional Accessories and Functions RS232/485 communication interface and software; LCD program controller; wireless alarm system; embedded printer; communication interface and embedded printer are alternative options that should be selected according to the required configuration
Performance Features
  • Microcomputer balancing temperature-humidity control improves stability for qualification, conditioned storage and repeatable environmental testing. This supports humidity-sensitive incubation, cultivation, conditioning and stability-study applications.
  • Imported compressor, fan and humidity-sensor components support dependable chamber performance across long laboratory schedules. This supports humidity-sensitive incubation, cultivation, conditioning and stability-study applications.
  • Mirror-finish stainless-steel interior and removable shelf supports make cleaning and chamber reconfiguration easier between test programs. This helps support repeated cleaning, chamber hygiene and long-duration laboratory use.
  • Independent over-temperature protection helps stop the chamber and notify operators when abnormal conditions appear. This reduces operational risk by helping protect samples and notifying operators when abnormal conditions occur.
  • Side test-port access supports external probes and measurement tasks during chamber verification or method development. This supports more reliable day-to-day use in industrial research, biotechnology testing, textile testing, material performance evaluation, product packaging studies and shelf-life or stability work.
  • Optional program control, communication, printer and wireless-alarm functions help document and supervise temperature-humidity studies. This supports humidity-sensitive incubation, cultivation, conditioning and stability-study applications.
APPLICATION SCOPE: Suitable for industrial research, biotechnology testing, textile testing, material performance evaluation, product packaging studies and shelf-life or stability work in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 850 x 1100 x 1930 mm, prepare the specified power supply, and keep air inlets, test ports, shelving, drain areas, doors and controller surfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment during unloading and positioning.
IMPORTANT NOTICE: Confirm the exact controller type, lighting form, humidity function, communication option and accessory package before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed according to the delivery location and shipping method.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The LHS-500HC-II constant temperature and humidity chamber requires specific environmental and infrastructure conditions for safe and reliable operation. Adherence to these constraints ensures proper performance and longevity of the equipment.

  • Ambient Temperature: The chamber must be operated in an ambient temperature range of 5 to 35°C.
  • Power Supply: The chamber requires a dedicated AC 220V, 50Hz power supply capable of delivering 3850W.
  • Installation Clearance: The installation space must accommodate the external dimensions of 850 x 1100 x 1930 mm with adequate clearance for air circulation and access.
  • Accessibility for Maintenance: Air inlets, test ports, shelving, drain areas, doors, and controller surfaces must remain accessible for cleaning and maintenance.
  • Transport Handling: During transport, the packed chamber must be kept upright and moved using suitable lifting equipment.

This procedure outlines the initial handling, installation, and setup steps to ensure safe and proper operation of the chamber. Follow these steps sequentially to avoid damage and ensure correct configuration.

Required Equipment: Suitable lifting equipment (e.g., forklift or pallet jack)

  1. Unload and Position the Packed Chamber
    Keep the packed chamber upright and use suitable lifting equipment during unloading and positioning.
  2. Confirm Installation Space
    Confirm that the installation space meets the external dimensions of 850 x 1100 x 1930 mm with adequate clearance.
  3. Prepare Power Supply
    Prepare the specified power supply of AC 220V, 50Hz, 3850W at the installation location.
  4. Ensure Accessibility for Maintenance
    Ensure that air inlets, test ports, shelving, drain areas, doors, and controller surfaces remain accessible for cleaning and maintenance.

What is the temperature fluctuation tolerance of the LHS-500HC-II chamber at high versus low temperature settings?

The chamber provides ±0.5°C fluctuation at high temperature and ±1°C at low temperature, as specified in the technical data. This difference reflects the balancing control logic of the microcomputer controller and the compressor performance across the operating range.

Can the LHS-500HC-II constant temperature and humidity chamber be integrated with external monitoring systems for data logging?

Yes, the chamber offers an optional RS232/485 communication interface and software for data output and external monitoring. Additionally, the side test port (standard) allows insertion of external probes for independent measurement verification during experiments.

What are the installation and power requirements for the 500L constant temperature and humidity chamber?

The chamber requires a 3850 W, AC 220 V, 50 Hz power supply and an ambient operating environment of +5 to 35°C. Installation space must accommodate external dimensions of 850 x 1100 x 1930 mm, with clear access to air inlets, test ports, shelving, drain areas, doors, and controller surfaces for cleaning and maintenance. The unit includes independent over-temperature protection that stops the chamber and alerts operators in abnormal conditions.

This 500L constant temperature and humidity chamber (Model LHS-500HC-II) provides stable environmental control via a microcomputer balancing controller and imported compressor, fan, and humidity sensor, making it suitable for industrial research, stability testing, and material evaluation. However, its 3850 W power draw and limited temperature/humidity ranges (10–70°C, 40–95%RH) require careful lab infrastructure planning and restrict low-humidity or sub-ambient applications.

Positive

  • Balanced temperature-humidity control logic: Microcomputer balancing control improves stability for qualification, conditioned storage, and repeatable environmental testing across humidity-sensitive applications.
  • Imported key components for reliability: The use of an imported compressor, circulation fan, and humidity sensor supports dependable performance over extended laboratory schedules, reducing downtime.

Trade-offs

  • Requires dedicated electrical infrastructure: The 3850 W power draw at AC 220V/50Hz and external dimensions of 850 x 1100 x 1930 mm demand careful lab layout planning and adequate power supply capacity.
  • Limited temperature and humidity range: Temperature control is restricted to 10–70°C and humidity to 40–95%RH, making the unit unsuitable for low-humidity or sub-ambient testing without additional conditioning modules.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).