Programmable Touchscreen Constant Temperature and Humidity Chamber, 500 L,-20-100℃
Research-grade laboratory product
Product Overview

Programmable Touchscreen Constant Temperature and Humidity Chamber, 500 L,-20-100℃ is a programmable touchscreen constant temperature and humidity chamber built for scientific research, biotechnology tests, pharmaceutical packaging, industrial raw-material studies and product lifetime evaluation. This configuration provides 500 l chamber volume, -20 to 100 C, 35%rh to 95%rh humidity control, imported 304 mirror-finish stainless-steel chamber interior and programmable color touchscreen controller with curve display and multi-language interface for stable day-to-day laboratory operation.

This family combines fluorine-free design, imported 304 stainless-steel inner chamber construction, balancing temperature-humidity control, test-port access and color-touchscreen editing as key chamber elements. The chamber combines balancing-control refrigeration system with multi-point safety protection with high-temperature humidity sensor for real-time monitoring, 3 shelves and an interior size of 670 x 720 x 1020 mm, supporting incubation, cultivation, climate simulation or conditioned test work where repeatable environmental control is important.

This range is intended for laboratories that want staged touchscreen programs, multilingual interface, stored curves, PID self-tuning and safety protection in one humidity-chamber platform. Installation planning can be based on the external size of 850 x 1100 x 1930 mm and the stated power requirement of 4150 W. Optional functions such as embedded printer; rs485 communication interface and software; wireless alarm system; communication interface and embedded printer are alternative options that should be selected according to the required configuration allow the unit to be adapted for alarm notification, data output, programmable operation, atmosphere support or other application-specific requirements.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-BCA0500
Manufacturer Model BPS-500CA
Capacity 500 L
Temperature Control Range -20 to 100 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity High temperature: +/- 0.5 C; low temperature: +/- 1 C
Humidity Function 35%RH to 95%RH
Humidity Deviation +/- 3%RH
Controller programmable color touchscreen controller with curve display and multi-language interface
Chamber Material imported 304 mirror-finish stainless-steel chamber interior
Power / Input 4150 W
Power Supply AC 220 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration high-temperature humidity sensor for real-time monitoring
Cooling System balancing-control refrigeration system with multi-point safety protection
Internal Dimensions 670 x 720 x 1020 mm
External Dimensions 850 x 1100 x 1930 mm
Shelves / Light Decks 3 shelves
Program Function Touchscreen controller supports up to 100 programs, 1000 segments and 999 cycle steps, with a maximum time setting of 99 h 59 min per segment
Optional Accessories and Functions embedded printer; RS485 communication interface and software; wireless alarm system; communication interface and embedded printer are alternative options that should be selected according to the required configuration
Performance Features
  • Color touchscreen operation helps simplify program editing, parameter review and real-time curve observation during chamber use. This improves parameter review, setpoint editing and day-to-day operation in controlled chamber workflows.
  • Large program capacity supports staged environmental methods that need repeated cycles and multiple segments. This supports staged test methods and repeatable laboratory workflows that need cycle-based control.
  • PID auto-tuning helps correct temperature and humidity deviations quickly for more stable chamber control. This supports humidity-sensitive incubation, cultivation, conditioning and stability-study applications.
  • Balancing-control refrigeration and imported stainless-steel chamber construction support reliable long-duration operation. This helps support repeated cleaning, chamber hygiene and long-duration laboratory use.
  • Independent alarm and protection functions cover over-temperature, overload, over-current, fan and compressor conditions. This helps maintain dependable low-temperature performance and stable chamber recovery during repeated use.
  • Optional communication, printer and wireless-alarm functions make it easier to store, replay and supervise chamber records. This reduces operational risk by helping protect samples and notifying operators when abnormal conditions occur.
APPLICATION SCOPE: Suitable for scientific research, biotechnology tests, pharmaceutical packaging, industrial raw-material studies and product lifetime evaluation in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 850 x 1100 x 1930 mm, prepare the specified power supply, and keep air inlets, test ports, shelving, drain areas, doors and controller surfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment during unloading and positioning.
IMPORTANT NOTICE: Confirm the exact controller type, lighting form, humidity function, communication option and accessory package before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed according to the delivery location and shipping method.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The chamber must be operated within an ambient temperature range of +5 to 30°C to maintain specified cooling performance. Electrical supply must be a dedicated AC 220 V, 50 Hz circuit with capacity for the 4150 W peak load, and the unit must be positioned with unobstructed airflow to the refrigeration system.

  • Power Supply: Connect the chamber to a dedicated AC 220 V, 50 Hz power supply with proper grounding and sufficient capacity for the 4150 W load.
  • Ambient Temperature: Maintain the working environment between +5 and 30°C to avoid overheating or insufficient cooling and humidity control.
  • Upright Transport: Keep the packed chamber upright at all times and use suitable lifting equipment during unloading and positioning.
  • Accessibility: Ensure air inlets, test ports, shelving, drain areas, doors, and controller surfaces remain accessible for cleaning and maintenance.

Unpack and position the chamber in the designated installation space, then connect to the specified power supply. Program the touchscreen controller with the desired environmental parameters and allow the chamber to stabilize before loading samples.

Required Equipment: Lifting equipment (e.g., forklift or pallet jack)

  1. Inspect and Unpack
    Inspect the chamber for any shipping damage before unpacking and keep the unit upright during removal of packaging.
  2. Position the Chamber
    Position the chamber in the designated installation space, ensuring adequate clearance for air inlets, test ports, and service access as per the external dimensions of 850 x 1100 x 1930 mm.
  3. Connect Power Supply
    Connect the chamber to a dedicated AC 220 V, 50 Hz power supply with proper grounding and verify the electrical connection meets the 4150 W requirement.
  4. Program Environmental Parameters
    Set the desired temperature, humidity, and program segments using the color touchscreen controller, utilizing up to 100 programs and 1000 segments.
  5. Stabilize Chamber
    Allow the chamber to stabilize at the set conditions, including PID auto-tuning if initiated, before loading any samples.

How does the temperature uniformity vary between high and low temperature setpoints in this chamber?

At high temperature setpoints, the temperature fluctuation and uniformity is ±0.5°C, while at low temperature setpoints it is ±1.0°C. This specification is directly stated in the product datasheet for the 500 L chamber.

What is the maximum program capacity of the touchscreen controller for staged environmental testing?

The programmable color touchscreen controller supports up to 100 programs, 1000 segments, and 999 cycle steps, with a maximum time setting of 99 hours and 59 minutes per segment. This allows complex, long-duration test protocols to be executed automatically.

What are the electrical supply and installation space requirements for the 500 L chamber?

The chamber requires an AC 220 V, 50 Hz power supply with a power input of 4150 W. External dimensions are 850 x 1100 x 1930 mm, and the working environment must be +5 to 30°C. Adequate clearance for air inlets, test ports, and maintenance access should be planned.

The Atomfair BPS-500CA (SKU: AF-LE-E-BPSC-0500-CA50) is a 500-liter programmable constant temperature and humidity chamber with a -20 to 100°C range and 35–95%RH, featuring a color touchscreen controller supporting 100 programs and PID auto-tuning, plus a 304 stainless-steel interior. Suitable for controlled environment studies, it requires a 4150 W, 220 V, 50 Hz power supply and an ambient temperature of 5–30°C.

Positive

  • Programmable Touchscreen with Curve Display: The color touchscreen controller supports up to 100 programs, 1000 segments, and 999 cycles, with PID auto-tuning for stable temperature and humidity control, enabling staged environmental methods and repeatable laboratory workflows.
  • 304 Stainless-Steel Chamber with Balancing Refrigeration: Imported 304 mirror-finish stainless-steel interior and balancing-control refrigeration system provide reliable long-duration operation, easy cleaning, and stable chamber recovery under repeated use.

Trade-offs

  • Ambient Temperature Requirement: The chamber's specified working environment is +5 to 30°C, necessitating installation in a temperature-controlled laboratory and limiting use in unconditioned spaces.
  • Electrical Power and Supply Dependency: The unit requires 4150 W at AC 220V 50 Hz, requiring dedicated power infrastructure and potentially limiting installation to facilities with compatible electrical systems.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).