Temperature and Humidity Chamber, 460 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
When the set temperature is 10 °C or below, ambient temperature must not exceed 26 °C to prevent performance degradation. When the set temperature exceeds 40 °C, set humidity below 80% RH to protect component service life.
- Low Set Temperature Constraint: If the chamber is set to 10 °C or lower, ensure the room temperature does not exceed 26 °C to avoid condensation or control errors.
- High Temperature and Humidity Constraint: For set temperatures above 40 °C, keep the humidity setpoint below 80% RH to reduce stress on the humidification and refrigeration systems.
Program the LCD controller with the desired temperature, humidity, and timer values using the step-by-step menu. After power interruption, the memory function will restore the last programmed settings automatically.
Required Equipment: LCD programmable controller, Magnetic sealing outer door, Tempered glass inner door
- Prepare chamber location
Place the chamber upright on a level surface with at least 15 cm clearance on all sides for air circulation and maintenance access. - Connect power supply
Plug the unit into a grounded AC 220 V, 50 Hz outlet rated for at least 1000 W continuous load. - Set temperature and humidity parameters
Program the target temperature between 5 and 50 °C and relative humidity between 50% and 90% on the LCD controller, observing the ambient temperature and cross-range constraints. - Set timer duration
Enter the operating time from 0 to 9999 minutes using the controller timer function to enable automatic shut-off. - Load samples
Distribute samples evenly on the two removable stainless-steel shelves, ensuring no blockage of the air ducts or contact with the inner walls. - Start the cycle
Press the start button on the controller to begin the programmed temperature and humidity cycle; monitor the multi-parameter display for real-time status. - Check after power interruption
After a power failure, verify that the controller has restored the previous settings via power-off memory before resuming the run.
What are the temperature and humidity operational limits for the Atomfair AF-HSP460BE chamber when running at high or low setpoints?
The chamber operates from 5 to 50°C and 50% to 90%RH. However, when the set temperature is above 40°C, humidity setpoints should generally not exceed 80%RH to protect service life. When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C. These constraints ensure stable performance and longevity.
Can the AF-HSP460BE chamber maintain humidity below 50%RH for applications like microbial culture or BOD testing?
No. The humidity control range is 50%RH to 90%RH with a deviation of <8%RH. The chamber cannot actively control humidity below 50%RH. For applications requiring lower humidity, a different chamber or dehumidification accessory would be needed.
What are the electrical and installation requirements for the 460 L temperature and humidity chamber?
The chamber requires a 1000 W power supply at AC 220 V, 50 Hz. It has an external footprint of 885 x 805 x 1795 mm and weighs 150 kg. It should be kept upright during transport and positioning, with sufficient service space around the unit for ventilation and maintenance. The ambient temperature must be considered when operating at low setpoints as noted.
The Atomfair AF-HSP460BE 460 L temperature and humidity chamber provides programmable environmental control with self-diagnosis and power-off memory, suitable for microbial culture and BOD measurement, but requires careful ambient temperature management at low setpoints and humidity limitation at high temperatures.
Positive
- Self-diagnosis and over-temperature limiting: Built-in self-diagnosis and over-temperature self-limiting protect samples and reduce operational risk during unattended runs.
- Power-off memory for continuous workflows: Power-off memory preserves all programmed settings after an interruption, enabling reliable continuation of long-term incubation or conditioning protocols.
Trade-offs
- Ambient temperature constraint at low setpoints: When the set temperature is 10 °C or below, the ambient temperature must not exceed 26 °C, limiting placement in warm laboratory environments.
- Humidity limitation at high set temperatures: When the set temperature exceeds 40 °C, the humidity setpoint should generally not exceed 80% RH to protect component service life.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).