Temperature Humidity Chamber 360 L AF-HSP360BE ATOMFAIR®

$2,200.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 360 L temperature and humidity chamber with 5–50 °C control, 50–90%RH range, 304 stainless-steel interior, 900 W input. Order now.

SKU: AF-LE-E-HSPB-0360-36BE
Category:
Brands:

Temperature and Humidity Chamber, 360 L
Research-grade laboratory product
Product Overview

Temperature and Humidity Chamber, 360 L is a practical chamber for environmental protection, epidemic prevention, veterinary research, drug testing, aquatic research, BOD measurement, microbial culture, plant cultivation and breeding tests. It brings together 360 l of usable space, 5 to 50 C, 50%rh to 90%rh humidity control, so the chamber can keep samples in a steady, repeatable working condition.

The inner door uses tempered glass, the outer door uses a magnetic sealing strip, and the ducted air system helps improve chamber uniformity and observation convenience. The cabinet uses a stainless-steel chamber with rounded corners, removable shelves, a magnetic door seal and hot-cold air ducts, with an internal working room of 595 x 600 x 1000 mm and an external footprint of 835 x 755 x 1695 mm. That combination of chamber size, shell build and liner material makes the unit easier to place, clean and use in routine laboratory work.

The series combines temperature and humidity control with memory and self-diagnosis functions so that the chamber can keep operating reliably after power interruptions or alarms. The stated input power is 900 W, and the timer range is 0 to 9999 min. It is well suited to the day-to-day work listed above, including culture, incubation, climate simulation or illuminated growth tasks, depending on the family.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-HSP360BE
Capacity 360 L
Temperature Control Range 5 to 50 C
Temperature Resolution 0.1 C
Temperature Fluctuation +/- 1 C
Humidity Range 50%RH to 90%RH
Humidity Deviation < 8%RH
Controller LCD screen with programmable temperature, humidity and time control
Chamber Material 304 stainless-steel working chamber
Exterior Shell Powder-coated steel shell
Power / Input 900 W
Power Supply AC 220 V, 50 Hz
Timer Range 0 to 9999 min
Internal Dimensions 595 x 600 x 1000 mm
External Dimensions 835 x 755 x 1695 mm
Net Weight 129.5 Kg
Shelves / Trays 2 shelves
Configuration Note Note: when set temperature is 10 C or below, ambient temperature should not exceed 26 C; when the set temperature is above 40 C, humidity setpoints should generally not exceed 80%
Performance Features
  • Self-diagnosis and over-temperature self-limiting help protect samples and reduce running risk. This supports more reliable day-to-day chamber use.
  • Power-off memory preserves settings after interruptions and supports continuous workflows. This helps preserve operation settings after power interruptions.
  • The embedded screen and multi-parameter display make operation and status review straightforward. This supports more reliable day-to-day chamber use.
  • The magnetic outer door seal and tempered-glass inner door improve sealing and observation. This improves observation and helps reduce heat loss while checking samples.
  • Hot and cold air ducts help improve chamber circulation and temperature uniformity. This helps improve chamber circulation and temperature uniformity.
  • Programmable temperature, humidity and time control suits repeatable laboratory methods. This is useful for cultivation, conditioning and biological workflows that need moisture control.
APPLICATION SCOPE: Suitable for environmental protection, epidemic prevention, veterinary research, drug testing, aquatic research, BOD measurement, microbial culture, plant cultivation and breeding tests in universities, laboratories, research institutes and quality-control environments that need controlled chamber performance.
HANDLING: Keep the chamber upright, maintain clear air paths and allow sufficient service space around the unit for ventilation and maintenance. Every unit is shipped with reinforced packaging for transport safety; keep the unit upright during unloading and positioning.
IMPORTANT NOTICE: When the set temperature is 10 C or below, ambient temperature should not exceed 26 C. When the set temperature is above 40 C, the humidity setpoint is normally kept below 80% to protect service life. Any quoted amount refers to the chamber body only and does not include freight. Freight should be confirmed separately according to the delivery destination.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This chamber requires a stable AC 220V 50Hz power supply and must be operated within specified ambient temperature limits to maintain performance. When set temperature is below 10°C, ambient temperature must not exceed 26°C; when set temperature exceeds 40°C, humidity setpoint should be kept below 80% to protect service life.

  • Power Supply Requirement: The unit must be connected to a dedicated AC 220V 50Hz outlet with sufficient capacity for the 900W load.
  • Ambient Temperature Limit: Ambient temperature must not exceed 26°C when the set temperature is 10°C or below.
  • Humidity Setpoint Limit: Humidity setpoint should not exceed 80% when the set temperature is above 40°C.
  • Handling and Positioning: Keep the chamber upright during transport and positioning, and maintain clear air paths around the unit.
  • Service Space: Allow sufficient service space around the unit for ventilation and maintenance access.

Position the chamber on a level surface with adequate clearance and connect to a grounded AC 220V 50Hz power supply. Program the desired temperature and humidity parameters via the LCD controller, observing ambient temperature and humidity limits for safe operation.

Required Equipment: LCD controller

  1. Position the chamber
    Position the chamber on a level surface with adequate clearance for ventilation and maintenance.
  2. Connect power
    Connect the unit to a grounded AC 220V 50Hz power outlet.
  3. Program parameters
    Program the desired temperature and humidity parameters via the LCD controller.
  4. Verify ambient temperature
    Verify that ambient temperature does not exceed 26°C when the set temperature is 10°C or below.
  5. Confirm humidity limit
    Confirm that humidity setpoint is below 80% when the set temperature exceeds 40°C.

What is the effective humidity control range when operating at elevated temperatures above 40°C?

When the set temperature exceeds 40°C, the humidity setpoint should generally not exceed 80% RH to protect service life. The standard humidity range is 50% to 90% RH, but at high temperatures the upper limit is reduced to 80% RH as stated in the configuration note.

What ambient temperature conditions are required when operating the chamber at low set temperatures (10°C or below)?

When the set temperature is 10°C or below, the ambient temperature should not exceed 26°C. This requirement is specified in the configuration note to ensure proper operation and avoid performance issues, given the chamber's temperature control range of 5 to 50°C.

What are the installation and handling requirements for the 360 L temperature and humidity chamber given its weight and dimensions?

The chamber weighs 129.5 kg with external dimensions 835 x 755 x 1695 mm. It must be kept upright during unloading and positioning, with clear air paths and sufficient service space around the unit for ventilation and maintenance. The unit is shipped with reinforced packaging for transport safety.

The Atomfair AF-HSP360BE 360 L temperature and humidity chamber provides a 304 stainless-steel work chamber with LCD-programmable control over 5–50 °C and 50–90% RH (±1 °C fluctuation, <8% RH deviation), making it suitable for microbial culture, BOD measurement, and stability testing. However, users must respect the ambient temperature constraint (≤26 °C when setpoint ≤10 °C) and the humidity derating (≤80% RH when setpoint >40 °C) to maintain operational stability.

Positive

  • Stainless-steel chamber with self-diagnostics: The 304 stainless-steel working chamber and over-temperature self-limiting function protect samples and reduce contamination risk during extended culture or incubation runs.
  • Power-off memory and programmable cycling: Memory retention after power interruption preserves critical settings, while the LCD controller supports programmable temperature, humidity, and time sequences for repeatable biological or environmental test protocols.

Trade-offs

  • Ambient-temperature derating for low setpoints: When the set temperature is 10 °C or below, ambient temperature must not exceed 26 °C, which may require air-conditioned lab spaces or careful thermal isolation in warm environments.
  • Humidity restricted at elevated temperatures: For setpoints above 40 °C, humidity should generally be kept below 80% RH to preserve equipment service life, limiting high-humidity/high-temperature combined testing.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).