Programmable Touchscreen Constant Temperature and Humidity Chamber, 250 L,-20-100℃
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This chamber requires a controlled ambient environment and a dedicated power supply for safe operation. Proper handling during transport and positioning is essential to prevent damage to the refrigeration system.
- Ambient Temperature Range: The working environment must be maintained between 5°C and 30°C to ensure stable refrigeration and humidity control.
- Power Supply Requirements: A dedicated AC 220 V, 50 Hz power supply with a capacity of 2700 W and proper grounding is required.
- Ventilation and Access: Air inlets, test ports, and controller surfaces must remain unobstructed for adequate airflow and operational access.
- Transport Orientation: The chamber must be kept upright during transport and positioning to prevent refrigerant migration or compressor damage.
- Interior Hygiene: The 304 stainless-steel interior should be cleaned regularly to maintain chamber hygiene and prevent corrosion.
Installation involves verifying space and power requirements, unpacking with care, and positioning for accessibility. Programming the touchscreen controller with staged parameters enables automated environmental testing.
Required Equipment: Lifting equipment
- Verify Installation Space
Confirm that the installation space meets the external dimensions of 750 x 900 x 1580 mm with adequate clearance for ventilation and maintenance. - Confirm Power Supply
Verify that the power supply matches the requirement of 2700 W, AC 220 V, 50 Hz with proper grounding. - Unpack Chamber
Unpack the chamber while keeping it upright and using suitable lifting equipment to avoid shock or tipping. - Position Chamber
Position the chamber so that air inlets, test ports, and controller surfaces remain accessible for operation and cleaning. - Configure Controller Program
Program the touchscreen controller with the desired temperature and humidity setpoints, program segments, and cycle steps for the test protocol.
What is the temperature uniformity specification for the Atomfair BPS-250CA chamber at high versus low temperature extremes?
At high temperature, uniformity is ±0.5°C; at low temperature, it is ±1°C. This is specified in the technical specifications for the 250L constant temperature and humidity chamber.
Does the Atomfair BPS-250CA support humidity control below 35%RH?
No, the humidity control range is 35%RH to 95%RH with a deviation of ±3%RH. The chamber does not support humidity below 35%RH as per the product specifications.
What are the installation space and power requirements for the 250L constant temperature and humidity chamber?
The external dimensions are 750 x 900 x 1580 mm, and the power requirement is 2700 W at AC 220V, 50 Hz. The working environment temperature should be between +5°C and 30°C. Ensure adequate clearance for air inlets and maintenance access.
The Atomfair BPS-250CA (SKU AF-LE-E-BPSC-0250-CA25) is a 250 L programmable temperature and humidity chamber with balancing-control refrigeration, a 304 stainless steel interior, and a color touchscreen controller supporting up to 100 programs and 1000 segments. It provides -20 to 100°C temperature control and 35% to 95% RH humidity control, making it suitable for incubation, stability testing, and climate simulation, but requires careful attention to power (2700 W, 220 V, 50 Hz) and ambient temperature (5-30°C) constraints.
Positive
- Large programmable control capacity: The touchscreen controller supports up to 100 programs, 1000 segments, and 999 cycles with a maximum segment time of 99 h 59 min, enabling complex staged test protocols and repeatable cycles for long-duration studies.
- Balancing refrigeration and stainless steel construction: The balancing-control refrigeration system combined with an imported 304 mirror-finish stainless steel interior provides stable temperature and humidity control, supports repeated cleaning, and ensures reliable long-term operation in laboratory environments.
Trade-offs
- Infrastructure and power requirements: The chamber requires a 2700 W, AC 220 V, 50 Hz power supply and an ambient operating temperature range of +5 to 30°C, necessitating dedicated electrical and environmental planning in the laboratory.
- Limited humidity and temperature precision: Humidity control is specified at ±3% RH deviation, and temperature uniformity is ±0.5°C at high temperatures and ±1°C at low temperatures, which may be insufficient for applications requiring tighter tolerances.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).