Simple Constant Temperature and Humidity Chamber, 150 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber operates within a temperature range of 10°C to 45°C (without humidification) and requires a stable AC 220V 50 Hz power supply. Continuous operation under heavy high-humidity load is restricted to prevent performance degradation.
- Power Supply Requirement: The chamber must be connected to a dedicated AC 220V 50 Hz power supply with proper grounding.
- Environmental Temperature Limit: The working environment must be maintained between +5°C and +35°C for reliable operation.
- Humidity Control Range: Humidity control is limited to 60%RH to 85%RH with a deviation of +/-5%RH to 8%RH.
- Continuous Operation Restriction: Continuous operation under heavy high-humidity load is not recommended beyond 180 hours to avoid performance degradation.
The chamber is shipped in reinforced packaging and must be kept upright during transport. Use suitable lifting equipment for unloading and positioning at the installation site.
Required Equipment: Lifting equipment (e.g., forklift or pallet jack)
- Transport
Keep the packed chamber upright during transport to prevent damage. - Unload
Use suitable lifting equipment to unload and position the chamber at the installation site. - Verify Space
Confirm the installation space accommodates the external dimensions of 690x800x1410 mm with adequate clearance. - Connect Power
Connect the chamber to a grounded AC 220V 50 Hz power supply as specified. - Accessibility Check
Ensure all air inlets, test ports, shelving, drain areas, doors, and controller surfaces are accessible for cleaning and maintenance.
How does the temperature uniformity of the LHS-150SC chamber vary between high and low temperature ranges?
The LHS-150SC exhibits temperature fluctuation/uniformity of ±1°C at high temperature and ±2°C at low temperature. Humidity deviation is ±5%RH to ±8%RH. These tolerances are typical for this simple series, which is designed for routine humidity work where a wider fluctuation band is acceptable.
What communication and data logging options are available for the Atomfair LHS-150SC chamber?
The LHS-150SC supports optional RS232/485 communication interface and software, as well as an embedded printer and wireless alarm system. These options allow data output, remote monitoring, and alarm notification, helping preserve run data when documentation is required.
What are the continuous operation recommendations for the LHS-150SC humidity chamber?
The LHS-150SC is recommended for continuous operation schedules of not less than 180 hours under proper installation conditions. However, it is not recommended for long uninterrupted operation under heavy high-humidity load, as the simple series is intended for routine humidity work and shorter-duration conditioned tasks.
The Simple Constant Temperature and Humidity Chamber, 150 L (model LHS-150SC) offers basic temperature and humidity control with an imported compressor, stainless-steel interior, and side test-port access, but its relatively wide humidity fluctuation (±5-8%RH) and the recommendation against extended heavy high-humidity operation make it best suited for routine, short-to-medium duration conditioning tasks rather than stringent long-term stability studies.
Positive
- Imported compressor with circulation fan: The imported compressor and circulation fan system provides reliable routine cooling performance and stable chamber recovery during repeated use, supporting dependable low-temperature operation.
- Stainless-steel chamber with rounded corners: The stainless-steel inner chamber with rounded corners and removable shelving facilitates cleaning and sample handling, improving hygiene and long-duration laboratory use.
Trade-offs
- Wide humidity fluctuation band: The humidity deviation of ±5%RH to 8%RH results in a wider fluctuation band than higher-grade chambers, which may be a limitation for precision humidity-sensitive applications.
- Not for heavy high-humidity long runs: The chamber is not recommended for long uninterrupted operation under heavy high-humidity loads, restricting its use for demanding continuous environmental testing.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).