Temperature-Humidity Chamber 100 L -10 to 85 °C ATOMFAIR®

$7,500.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 100 L temperature-humidity chamber with -10 to 85 °C control, 45-95%RH range, ±3%RH deviation, 1900 W power and 2 shelves.

SKU: AF-LE-E-LHBC-0100-CL10
Category:
Brands:

Balanced-Control Constant Temperature and Humidity Chamber, 100 L,45-95%RH
Research-grade laboratory product
Product Overview

Balanced-Control Constant Temperature and Humidity Chamber, 100 L,45-95%RH is a balanced-control constant temperature and humidity chamber built for animal, textile, food-processing, material and packaging tests that require balanced temperature-humidity chamber control. This configuration provides 100 l chamber volume, -10 to 85 C, 45%rh to 95%rh humidity control, mirror-finish stainless-steel chamber interior and microcomputer balancing temperature and humidity controller for stable day-to-day laboratory operation.

This family combines fluorine-free design, mirror-finish stainless-steel inner chamber, balancing control, imported key components, independent over-temperature alarm and a 25 mm test port as core construction points. The chamber combines environment-friendly refrigeration system on CL, CA and CB versions with imported humidity sensor and balancing-control package, 2 shelves and an interior size of 500 x 400 x 550 mm, supporting incubation, cultivation, climate simulation or conditioned test work where repeatable environmental control is important.

The CH, CL, CA and CB configurations give a choice of non-refrigerated and refrigerated temperature bands, allowing users to match humidity-chamber capability to routine environmental tests. Installation planning can be based on the external size of 650 x 800 x 1310 mm and the stated power requirement of 1900 W. Optional functions such as rs485 communication interface and software; lcd program controller; wireless alarm system; embedded printer; communication interface and embedded printer are alternative options that should be selected according to the required configuration allow the unit to be adapted for alarm notification, data output, programmable operation, atmosphere support or other application-specific requirements.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-LBL0100
Manufacturer Model LHS-100CL
Capacity 100 L
Temperature Control Range -10 to 85 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity +/- 1 C
Humidity Function 45%RH to 95%RH
Humidity Deviation +/- 3%RH
Controller microcomputer balancing temperature and humidity controller
Chamber Material mirror-finish stainless-steel chamber interior
Power / Input 1900 W
Power Supply AC 220 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration imported humidity sensor and balancing-control package
Cooling System environment-friendly refrigeration system on CL, CA and CB versions
Internal Dimensions 500 x 400 x 550 mm
External Dimensions 650 x 800 x 1310 mm
Shelves / Light Decks 2 shelves
Optional Accessories and Functions RS485 communication interface and software; LCD program controller; wireless alarm system; embedded printer; communication interface and embedded printer are alternative options that should be selected according to the required configuration
Performance Features
  • Balancing temperature-humidity control helps maintain a stable operating band for routine environmental testing. This supports humidity-sensitive incubation, cultivation, conditioning and stability-study applications.
  • Mirror-finish stainless-steel inner surfaces with removable shelving make cleaning and chamber preparation easier between test runs. This helps support repeated cleaning, chamber hygiene and long-duration laboratory use.
  • Independent over-temperature alarm protection improves safety during unattended conditioned testing. This reduces operational risk by helping protect samples and notifying operators when abnormal conditions occur.
  • Model-specific low-temperature bands let the user choose between non-refrigerated, -10 C, -20 C or -40 C starting points. This supports more reliable day-to-day use in animal, textile, food-processing, material and packaging tests that require balanced temperature-humidity chamber control.
  • Side test-port access helps chamber verification and external measurement tasks. This supports more reliable day-to-day use in animal, textile, food-processing, material and packaging tests that require balanced temperature-humidity chamber control.
  • Optional communication, printer, wireless-alarm and program-controller functions support more traceable chamber operation. This improves parameter review, setpoint editing and day-to-day operation in controlled chamber workflows.
APPLICATION SCOPE: Suitable for animal, textile, food-processing, material and packaging tests that require balanced temperature-humidity chamber control in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 650 x 800 x 1310 mm, prepare the specified power supply, and keep air inlets, test ports, shelving, drain areas, doors and controller surfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment during unloading and positioning.
IMPORTANT NOTICE: Confirm the exact controller type, lighting form, humidity function, communication option and accessory package before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed according to the delivery location and shipping method.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

Must operate within +5 to 30°C ambient temperature and AC 220V 50Hz power supply. Unit must remain upright during transport and have accessible air inlets and test ports for safe operation.

  • Electrical Safety: The chamber requires a dedicated AC 220V 50Hz power supply with a 1900W capacity.
  • Environmental Limits: Ambient temperature must be maintained between 5°C and 30°C to ensure proper operation.
  • Installation Positioning: Keep the chamber upright and use suitable lifting equipment during unloading and positioning.
  • Over-Temperature Protection: The independent over-temperature alarm system must be verified before unattended operation.
  • Accessibility: Air inlets, test ports, shelving, and door areas must remain accessible for cleaning and maintenance.

Follow these steps to safely install and initialize the chamber for humidity-controlled testing. Ensure the power supply and ambient conditions meet specifications before operation.

Required Equipment: Lifting equipment

  1. Verify Installation Space
    Confirm the installation space against the stated external dimensions of 650 x 800 x 1310 mm and ensure air inlets remain accessible.
  2. Position the Chamber
    Use suitable lifting equipment to unload and position the chamber, keeping it upright at all times.
  3. Connect Power Supply
    Connect the chamber to a dedicated AC 220V 50Hz power supply with a 1900W capacity.
  4. Set Control Parameters
    Set the temperature and humidity parameters using the microcomputer balancing controller.
  5. Enable Over-Temperature Alarm
    Enable the independent over-temperature alarm and verify its operation before unattended use.

What is the temperature and humidity stability of the LHS-100CL constant temperature and humidity chamber?

The LHS-100CL chamber provides temperature fluctuation and uniformity of +/-1°C and humidity deviation of +/-3%RH. This is achieved using a microcomputer balancing temperature and humidity controller combined with an imported humidity sensor and balancing-control package.

Can the LHS-100CL chamber be integrated with external data logging or monitoring systems?

Yes, the chamber can be equipped with an optional RS485 communication interface and software for data logging and remote monitoring. Additional optional accessories include an LCD program controller, wireless alarm system, and embedded printer to support traceable operation, alarm notification, and programmable setpoint control.

What are the installation and safety requirements for the LHS-100CL chamber?

The chamber requires an installation space of 650 x 800 x 1310 mm, a power supply of AC 220 V, 50 Hz at 1900 W, and an ambient working environment of +5 to 30°C. It features an independent over-temperature alarm for safety during unattended operation. The unit must be kept upright during transport and positioned with accessible air inlets, test ports, drain areas, and control surfaces.

The LHS-100CL (AF-LBL0100) is a 100 L balanced-control constant temperature and humidity chamber with a -10 to 85 °C range and 45-95%RH humidity control, featuring a mirror-finish stainless-steel interior and an environment-friendly refrigeration system. Its microcomputer balancing controller and imported humidity sensor provide stable conditions for animal, textile, food-processing, material, and packaging tests, though the 1900 W power requirement and +5 to 30 °C working environment limit placement and infrastructure flexibility.

Positive

  • Balanced temperature-humidity control: The microcomputer balancing controller and imported humidity sensor maintain stable temperature and humidity within ±1 °C and ±3%RH, supporting repeatable incubation, cultivation, and conditioning tests.
  • Mirror-finish stainless-steel interior: The corrosion-resistant, easy-to-clean inner chamber with removable shelving facilitates hygiene and reduces cross-contamination risk between test runs.

Trade-offs

  • Narrow working environment range: The chamber requires an ambient temperature of +5 to 30 °C, limiting installation to climate-controlled laboratory spaces and precluding use in unconditioned or hot environments.
  • High continuous power draw: With a 1900 W power requirement at 220 V/50 Hz, the unit demands dedicated electrical infrastructure and may increase operational costs during extended test cycles.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).